Indications for transvenous lead extraction and its procedural and early outcomes in elderly patients: a single-center experience

被引:3
作者
Zabek, Andrzej [1 ]
Boczar, Krzysztof [1 ]
Debskil, Maciej [1 ]
Pfitzner, Roman [2 ,3 ]
Ulmanl, Mateusz [1 ]
Holcman, Katarzyna [2 ,4 ]
Kostkiewicz, Magdalena [2 ,4 ]
Musial, Robert [5 ]
Lelakowski, Jacek [1 ,2 ]
Malecka, Barbara [1 ,2 ]
机构
[1] John Paul 2 Hosp, Dept Electrocardiol, Ul Pradnicka 80, PL-31202 Krakow, Poland
[2] Jagiellonian Univ, Inst Cardiol, Med Coll, Krakow, Poland
[3] John Paul 2 Hosp, Dept Cardiovasc Surg, Krakow, Poland
[4] John Paul 2 Hosp, Dept Cardiac & Vasc Dis, Krakow, Poland
[5] John Paul 2 Hosp, Dept Anesthesiol & Intens Therapy, Krakow, Poland
来源
POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ | 2020年 / 130卷 / 03期
关键词
cardiovascular implantable electronic devices; effectiveness; elderly; safety; transvenous lead extraction; PREDICTORS; MORTALITY; DEFIBRILLATOR; PACEMAKER; REGISTRY; SAFETY; 30-DAY; OLDER;
D O I
10.20452/pamw.15182
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
INTRODUCTION Due to the prolonged survival of patients with cardiovascular implantable electronic devices, leads often need to be removed in elderly individuals. OBJECTIVES We aimed to analyze indications for transvenous lead extraction (TLE), procedure effectiveness and safety, as well as 30-day follow-up in younger patients (<= 80 years) and octogenarians (>80 years). PATIENTS AND METHODS This prospective study included 667 patients who underwent TLE: 90 octogenarians (13.5%) at a mean age of 83.8 (range, 80.4-93) years and 577 younger patients (86.5%) at a mean age of 64.2 (range, 18.9-79.9) years. RESULTS Octogenarians had a greater number of comorbidities, fewer implantable cardioverter-defibrillators implanted, and more frequently had infection as an indication for TLE, as compared with younger patients (33.3% vs 17.1%; P <0.001). In octogenarians, 138 leads were extracted, as compared with 894 leads in younger patients. Octogenarians and younger patients had similar rates of complete lead removal (98.6% and 97.1%, respectively; P = 0.48), total procedural success (97.8% and 96%, respectively; P = 0.7), major complications (0% and 1.6%, respectively; P = 0.45), and minor complications (2.2% and 1.6%, respectively; P = 0.45). There was 1 death associated with TLE in younger patients. Non-procedure-related deaths within 30 days after TLE were more frequent in octogenarians than in younger patients (5.6% vs 1.9%; P = 0.04). CONCLUSIONS We showed that TLE in patients older than 80 years seems to be as effective as in younger patients; however, it is associated with significantly higher non-procedure-related 30-day mortality.
引用
收藏
页码:216 / 224
页数:9
相关论文
共 50 条
[1]   Large, Single-Center Experience in Transvenous Coronary Sinus Lead Extraction: Procedural Outcomes and Predictors for Mechanical Dilatation [J].
Di Cori, Andrea ;
Bongiorni, Maria Grazia ;
Zucchelli, Giulio ;
Segreti, Luca ;
Viani, Stefano ;
De Lucia, Raffaele ;
Paperini, Luca ;
Soldati, Ezio .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (02) :215-222
[2]   Outcomes of transvenous lead extraction in patients with lead perforation: A single-center experience [J].
Zhou, Xu ;
Ze, Feng ;
Li, Ding ;
Wang, Long ;
Guo, Jihong ;
Li, Xuebin .
CLINICAL CARDIOLOGY, 2020, 43 (04) :386-393
[3]   Large, single-center, single-operator experience with transvenous lead extraction: Outcomes and changing indications [J].
Jones, Samuel O. ;
Eckart, Robert E. ;
Albert, Christine M. ;
Epstein, Laurence M. .
HEART RHYTHM, 2008, 5 (04) :520-525
[4]   Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads-A Single-Center Experience [J].
Akcay, Murat ;
Yuksel, Serkan .
MEDICINA-LITHUANIA, 2024, 60 (08)
[5]   Transvenous Lead Extraction without Procedure-Related Deaths in 1000 Consecutive Patients: A Single-Center Experience [J].
Stefanczyk, Pawel ;
Nowosielecka, Dorota ;
Tulecki, Lukasz ;
Tomkow, Konrad ;
Polewczyk, Anna ;
Jachec, Wojciech ;
Kleinrok, Andrzej ;
Borzecki, Wojciech ;
Kutarski, Andrzej .
VASCULAR HEALTH AND RISK MANAGEMENT, 2021, 17 :445-459
[6]   Transvenous lead extraction in patients with prior extraction procedures: Procedural profiles and outcomes [J].
Hutt, Erika ;
Diab, Mohamed ;
Wazni, Oussama M. ;
Kaur, Simrat ;
Tarakji, Khaldoun G. ;
Saliba, Walid I. ;
Kanj, Mohamed ;
Cantillon, Daniel ;
Rickard, John ;
Varma, Niraj ;
Callahan, Thomas ;
Martin, David O. ;
Niebauer, Mark ;
Dresing, Thomas ;
Chung, Mina ;
Wilkoff, Bruce L. ;
Hussein, Ayman A. .
HEART RHYTHM, 2020, 17 (11) :1904-1908
[7]   Safe and effective transvenous lead extraction for elderly patients utilizing non-laser and laser tools: a single-center experience in Japan [J].
Okada, Ayako ;
Tabata, Hiroaki ;
Shoda, Morio ;
Shoin, Wataru ;
Kobayashi, Hideki ;
Okano, Takahiro ;
Yoshie, Koji ;
Kato, Ken ;
Saigusa, Tatsuya ;
Ebisawa, Soichiro ;
Motoki, Hirohiko ;
Kuwahara, Koichiro .
HEART AND VESSELS, 2021, 36 (06) :882-889
[8]   Effectiveness and safety of transvenous extraction of single-versus dual-coil implantable cardioverter-defibrillator leads at single-center experience [J].
Zabek, Andrzej ;
Boczar, Krzysztof ;
Debski, Maciej ;
Ulman, Mateusz ;
Pfitzner, Roman ;
Musial, Robert ;
Lelakowski, Jacek ;
Malecka, Barbara .
MEDICINE, 2019, 98 (30)
[9]   The analysis of indications and early results of transvenous lead extraction in patients with a pacemaker, ICD and CRT - single-centre experience [J].
Zabek, Andrzej ;
Malecka, Barbara ;
Haberka, Kazimierz ;
Boczar, Krzysztof ;
Pfitzner, Roman ;
Debski, Maciej ;
Lelakowski, Jacek .
ACTA CARDIOLOGICA, 2015, 70 (06) :685-692
[10]   Outcome of transvenous lead extraction in nonagenarians: A single-center retrospective study [J].
Komatsu, Toshinori ;
Okada, Ayako ;
Shoda, Morio ;
Tanaka, Kiu ;
Kobayashi, Hideki ;
Oguchi, Yasutaka ;
Saigusa, Tatsuya ;
Ebisawa, Soichiro ;
Motoki, Hirohiko ;
Kuwahara, Koichiro .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, :1293-1299