Registration Accuracy of CT/MRI Fusion for Localisation of Deep Brain Stimulation Electrode Position: An Imaging Study and Systematic Review

被引:55
作者
Geevarghese, Ruben [1 ,2 ]
Tuura, Ruth O'Gorman [6 ]
Lumsden, Daniel E. [4 ]
Samuel, Michael [3 ]
Ashkan, Keyoumars [2 ,5 ]
机构
[1] Kings Coll Hosp NHS Fdn Trust, Kings Hlth Partners, Dept Neurosurg, Charing Cross Hosp, London, England
[2] Kings Coll Hosp NHS Fdn Trust, Kings Hlth Partners, Dept Neurosurg, London, England
[3] Kings Coll Hosp NHS Fdn Trust, Kings Hlth Partners, Dept Neurol, London, England
[4] Guys & St Thomas NHS Fdn Trust, Evelina Childrens Hosp, Complex Motor Disorders Serv, London, England
[5] Inst Psychiat, Clin Neurosci, London, England
[6] Univ Childrens Hosp, Dept MR Res, Zurich, Switzerland
关键词
Accuracy; CT; Deep brain stimulation; Electrode; Image registration; MRI; Review; PARKINSONS-DISEASE; MRI; CT;
D O I
10.1159/000446609
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Postoperative imaging is essential for verifying electrode location in patients undergoing deep brain stimulation (DBS). MRI offers better visualisation of brain targets, but concerns about adverse events have limited its use. Preoperative stereotactic MRI fused with a postoperative stereotactic CT, demonstrating the electrode position, is now widely used. Objectives: The aims of this study were to: (1) evaluate the accuracy of image registration using Neuroinspire, and (2) undertake a systematic review of the literature on CT/MRI fusion techniques to ascertain the accuracy of other software packages. Methods: Twenty patients who underwent bilateral subthalamic nucleus DBS for Parkinson's disease were selected. The postoperative CT was registered and fused with the preoperative MRI using Neuroinspire. The position of each electrode tip was determined in stereotactic coordinates both in the (unfused) postoperative CT and the fused CT/MRI. The difference in tip position was used to evaluate the registration accuracy. Results: The mean error +/- SD of CT/MRI fusion using Neuroinspire was 0.25 +/- 0.15, 0.33 +/- 0.26 and 0.46 +/- 0.55 mm in lateral, anteroposterior and vertical axes. A systematic review suggested that CT/MRI registration with Neuroinspire is more accurate than that achieved with other tested CT/MRI fusion algorithms. Conclusion: CT/MRI fusion for localisation of electrode placement offers an accurate, reliable and safe modality for assessing electrode location. (C) 2016 S. Karger AG, Basel
引用
收藏
页码:159 / 163
页数:5
相关论文
共 16 条
[1]  
[Anonymous], DEEP BRAIN STIM PARK
[2]   Evaluation of electrode position in deep brain stimulation by image fusion (MRI and CT) [J].
Barnaure, I. ;
Pollak, P. ;
Momjian, S. ;
Horvath, J. ;
Lovblad, K. O. ;
Boex, C. ;
Remuinan, J. ;
Burkhard, P. ;
Vargas, M. I. .
NEURORADIOLOGY, 2015, 57 (09) :903-908
[3]   Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording Clinical article [J].
Burchiel, Kim J. ;
McCartney, Shirley ;
Lee, Albert ;
Raslan, Ahmed M. .
JOURNAL OF NEUROSURGERY, 2013, 119 (02) :301-306
[4]   A simple method to assess accuracy of deep brain stimulation electrode placement: Pre-operative stereotactic CT plus postoperative MR image fusion [J].
Ferroli, P ;
Franzini, A ;
Marras, C ;
Maccagnano, E ;
D'Incerti, L ;
Broggi, G .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2004, 82 (01) :14-19
[5]   The Safety of Using Body-Transmit MRI in Patients with Implanted Deep Brain Stimulation Devices [J].
Kahan, Joshua ;
Papadaki, Anastasia ;
White, Mark ;
Mancini, Laura ;
Yousry, Tarek ;
Zrinzo, Ludvic ;
Limousin, Patricia ;
Hariz, Marwan ;
Foltynie, Tom ;
Thornton, John .
PLOS ONE, 2015, 10 (06)
[6]   Magnetic resonance imaging of implanted deep brain stimulators: Experience in a large series [J].
Larson, Paul S. ;
Richardson, R. Mark ;
Starr, Philip A. ;
Martin, Alastair J. .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2008, 86 (02) :92-100
[7]  
Medtronic, MRI GUID 2015
[8]   CT/MR Image Fusion in the Postoperative Assessment of Electrodes Implanted for Deep Brain Stimulation [J].
O'Gorman, Ruth L. ;
Jarosz, Josef M. ;
Samuel, Michael ;
Clough, Chris ;
Selway, Richard P. ;
Ashkan, Keyoumars .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2009, 87 (04) :205-210
[9]   Cognition and Mood in Parkinson's Disease in Subthalamic Nucleus versus Globus Pallidus Interna Deep Brain Stimulation: The COMPARE Trial [J].
Okun, Michael S. ;
Fernandez, Hubert H. ;
Wu, Samuel S. ;
Kirsch-Darrow, Lindsey ;
Bowers, Dawn ;
Bova, Frank ;
Suelter, Michele ;
Jacobson, Charles E. ;
Wang, Xinping ;
Gordon, Clifford W., Jr. ;
Zeilman, Pam ;
Romrell, Janet ;
Martin, Pam ;
Ward, Herbert ;
Rodriguez, Ramon L. ;
Foote, Kelly D. .
ANNALS OF NEUROLOGY, 2009, 65 (05) :586-595
[10]   Deep brain stimulation for Parkinson disease in Australia: current scientific and clinical status [J].
Poortvliet, P. C. ;
Silburn, P. A. ;
Coyne, T. J. ;
Chenery, H. J. .
INTERNAL MEDICINE JOURNAL, 2015, 45 (02) :134-139