Modelling tri-cortical pedicle screw fixation in thoracic vertebrae under osteoporotic condition: A finite element analysis based on computed tomography

被引:13
作者
Zhang, Wencan [1 ]
Zhao, Junyong [2 ]
Li, Le [1 ]
Yu, Chenxiao [1 ]
Zhao, Yuefeng [2 ]
Si, Haipeng [1 ]
机构
[1] Shandong Univ, Qilu Hosp, Jinan 250012, Peoples R China
[2] Shandong Normal Univ, Coll Phys & Elect Sci, Jinan 250000, Peoples R China
基金
中国博士后科学基金;
关键词
Tri-cortical pedicle screw; Biomechanics; Finite element analysis; 3D medical image reconstruction; Computed tomography; SPINE; COMPLICATIONS; BIOMECHANICS; PLACEMENT; FRACTURE; SEGMENT;
D O I
10.1016/j.cmpb.2019.105035
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: The technique of tri-cortical pedicle screw (TCPS) has been used to improve the anchoring strength in the sacral vertebrae. However, no studies have reported their application in the thoracic vertebrae. Our research is aimed to assess the stability and strength of the TCPS in thoracic vertebrae under osteoporotic condition by three dimensional (3D) finite element method on the basis of medical image reconstruction using computed tomography (CT), and verifying its effectiveness in clinical application. Materials and methods: The 3D finite element models were constructed using Mimcs to transfer two dimensional CT images into 3D models by marching cubes algorithm of six-partition. Six physiological activities were simulated in 3D finite element models. Compared with the strength and stability of the uni-cortical pedicle screw (UCPS) and bi-cortical pedicle screw (BCPS), the effectiveness of TCPS was assessed. The stress distribution and maximum stress were measured to evaluate the strength. The maximum displacement and the range of motion were analysed to assessed the stability. Experimental results: Four geometrically accurate and nonlinear T7-T9 finite element models were constructed successfully by 3D finite element method based on the CT images. Three kinds of internal fixation methods in the osteoporotic thoracic vertebral body can improved the maximum stress, decrease the maximum displacement and range of motion in six physiological activities. The range of motion and maximum displacement of TCPS decreased more significantly than that of UCPS and BCPS. The maximum von Mises stress of TCPS was minimum and UCPS was maximum under the condition of extension, right lateral bending, left rotation and right rotation. Conclusions: Effectively, TCPS can provide better stability and strength than that of UCPS and BCPS techniques in the osteoporotic thoracic vertebrae. In practice, the technique of TCPS can be applied in the osteoporotic thoracic vertebral body to enhance the griping strength of the screws and reduce the risk of pedicle screw loosening. However, further cadaver experiments and more biomechanical analysis are necessary to confirmed our findings. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 28 条
  • [1] [Anonymous], [No title captured]
  • [2] Generation of 3D isosurfaces by means of the marching cube algorithm
    Bartsch, M
    Weiland, T
    Witting, M
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1996, 32 (03) : 1469 - 1472
  • [3] In vivo accuracy of thoracic pedicle screws
    Belmont, PJ
    Klemme, WR
    Dhawan, A
    Polly, DW
    [J]. SPINE, 2001, 26 (21) : 2340 - 2346
  • [4] Bozík M, 2014, ACTA CHIR ORTHOP TR, V81, P140
  • [5] SCREW FIXATION IN THE HUMAN SACRUM - AN INVITRO STUDY OF THE BIOMECHANICS OF FIXATION
    CARLSON, GD
    ABITBOL, JJ
    ANDERSON, DR
    KRAG, MH
    KOSTUIK, JP
    WOO, SLY
    GARFIN, SR
    [J]. SPINE, 1992, 17 (06) : S196 - S203
  • [6] Biomechanical comparison of anterior lumbar interbody fusion: stand-alone interbody cage versus interbody cage with pedicle screw fixation - a finite element analysis
    Choi, Kyung-Chul
    Ryu, Kyeong-Sik
    Lee, Sang-Ho
    Kim, Yeong Hyeon
    Lee, Sung Jae
    Park, Chun-Kun
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [7] Complications of thoracic pedicle screws in scoliosis treatment
    Di Silvestre, Mario
    Parisini, Patrizio
    Lolli, Francesco
    Bakaloudis, Georgios
    [J]. SPINE, 2007, 32 (15) : 1655 - 1661
  • [8] Effectiveness of pedicle screw inclusion at the fracture level in short-segment fixation constructs for the treatment of thoracolumbar burst fractures: a computational biomechanics analysis
    Elmasry, Shady
    Asfour, Shihab
    Travascio, Francesco
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (13) : 1412 - 1420
  • [9] Complications of Pedicle Screw Fixation in Scoliosis Surgery A Systematic Review
    Hicks, John M.
    Singla, Amit
    Shen, Francis H.
    Arlet, Vincent
    [J]. SPINE, 2010, 35 (11) : E465 - E470
  • [10] Inanmaz M.E., 2013, J SPINAL DISORD TECH, V29