MULTISCALE DEFORMABLE REGISTRATION USING EDGE PRESERVING SCALE SPACE FOR ADAPTIVE RADIATION THERAPY

被引:0
|
作者
Li, Dengwang [1 ]
Wang, Xiuying [2 ]
Wang, Hongjun [1 ]
Yin, Yong [1 ,3 ]
Feng, David Dagan [2 ,4 ]
机构
[1] Shandong Univ, Sch Informat Sci & Engn, Jinan, Peoples R China
[2] Univ Sydney, Biomed & Multimedia Informat Technol Res Grp, Sydney, NSW 2006, Australia
[3] Shandong Tumor Hosp, Dept Radiat Oncol, Shandong, Peoples R China
[4] Hong Kong Polytech Univ, Ctr Multimedia Signal Proc, Hong Kong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
image registration; edge preserving; multiscale; free form deformation; cone beam CT; MUTUAL-INFORMATION; IMAGE REGISTRATION; OPTIMIZATION;
D O I
10.1109/ICIP.2010.5653345
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Registration of planning images with daily images is an important component for adaptive radiation therapy (ART). In this paper, a multiscale deformable registration framework is proposed by combining edge preserving scale space with the free form deformation (FFD) for registration of planning computed tomography (CT) images with daily cone beam CT (CBCT) images. The edge preserving scale space which is able to select edges and contours of an image according to their geometric size is derived from the total variation model with the L1 norm (TV-L1). At each scale, the selected edges and contours are sufficiently strong to drive the deformation using the FFD grid, then the deformation fields are gained by a coarse to fine manner. Furthermore, for automated registration we design an optimal estimation of the TV-L1 parameter by minimizing the defined offset. The experiments on CT and CBCT images show accuracy and robustness when compared to traditional methods.
引用
收藏
页码:4409 / 4412
页数:4
相关论文
共 50 条
  • [1] Deformable Registration Using Edge Preserving Scale Space for Adaptive Image Guided Radiation Therapy
    Chen, J.
    Li, D.
    MEDICAL PHYSICS, 2011, 38 (06) : 3420 - +
  • [2] Deformable registration using edge-preserving scale space for adaptive image-guided radiation therapy
    Li, Dengwang
    Wang, Hongjun
    Yin, Yong
    Wang, Xiuying
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 105 - 123
  • [3] Multiscale registration of medical images based on edge preserving scale space with application in image-guided radiation therapy
    Li, Dengwang
    Li, Hongsheng
    Wan, Honglin
    Chen, Jinhu
    Gong, Guanzhong
    Wang, Hongjun
    Wang, Liming
    Yin, Yong
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (16): : 5187 - 5204
  • [4] Deformable Registration of 4-dimensional Computed Tomography Data Using Edge Preserving Scale Space
    Li, D.
    Li, H.
    Yin, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S809 - S809
  • [5] VALIDATION OF DEFORMABLE REGISTRATION IN ADAPTIVE RADIATION THERAPY WITH SCALE INVARIANT FEATURE TRANSFORM
    Chiara, Paganelli
    Marta, Peroni
    Guido, Baroni
    Marco, Riboldi
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 680 - 683
  • [6] Deformable registration using scale space keypoints
    Moradi, Mehdi
    Abolmaesoumi, Purang
    Mousavi, Parvin
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [7] Assessment of Adaptive Radiation Therapy With deformable Image Registration Software
    Mukumoto, N.
    Yada, R.
    Shimizu, Y.
    Okumura, K.
    Wang, T.
    Osuga, S.
    Akasaka, H.
    Aoyama, Y.
    Sasaki, R.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [8] Improved dose accuracy for on-line adaptive radiation therapy using deformable dose registration
    Siebers, J
    Murphy, M
    Fix, M
    MEDICAL PHYSICS, 2005, 32 (06) : 1934 - 1934
  • [9] Improving Deformable Image Registration Accuracy using a Hybrid Similarity Metric for Adaptive Radiation Therapy
    Shah, Keyur
    Shackleford, James A.
    Kandasamy, Nagarajan
    Sharp, Gregory C.
    MEDICAL IMAGING 2021: IMAGE PROCESSING, 2021, 11596
  • [10] Deformable image registration in radiation therapy
    Dowling, Jason A.
    O'Connor, Laura M.
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (04) : 257 - 259