Early detection of hearing impairment in type 2 diabetic patients

被引:7
|
作者
Li, Yanhong [1 ,2 ]
Liu, Bo [1 ,2 ]
Li, Jin [1 ,2 ]
Xin, Lingyu [1 ,2 ]
Zhou, Qian [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Dept Otolaryngol Head & Neck Surg, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Inst Otolaryngol, Key Lab Otolaryngol Head & Neck Surg, Minist Educ, Beijing, Peoples R China
关键词
Type 2 diabetes mellitus; hearing impairment; early; extended high frequency audiometry; evoked distortion product otoacoustic emissions; MELLITUS; ADULTS;
D O I
10.1080/00016489.2019.1680863
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: Hearing impairment is an under-recognized complication of type 2 diabetic patients. Exploring an appropriate technique and method to detect early hearing impairment in diabetic patients is the key to good hearing care. Objectives: The objectives of this study are to evaluate the application effects of extended high-frequency audiometry and distortion product otoacoustic emissions in early detection of hearing impairment in diabetic patients. Materials and methods: The study recruited 65 type 2 diabetic patients with normal hearing thresholds detected by conventional PTA, and 60 control subjects. All subjects completed detailed medical history questionnaires and underwent ENT (Ear, Nose and Throat) physical examinations and laboratory tests. Then they underwent the conventional pure tone audiometry (PTA) tests, extended high frequency audiometry (HFA) and distortion product of otoacoustic emissions (DPOAEs). Audiologic data and the related risk factors of audiology were analyzed. Results: Of 65 diabetic patients, 41 patients (63.1%) suffered from high frequency hearing loss detected by HFA and 58 patients (89.2%) suffered from cochlear dysfunction detected by DPOAEs. The incidence of high frequency hearing loss was 38%, 83.3% and 42.3% at the age of 30-39, 40-49 and 50-59 years, respectively. The factors of age (p = .00) and disease duration (p = .00) were related with the high frequency hearing threshold, while the factor of glycosylated hemoglobin (HbA1c) (p = .716) had no relationship with it. Conclusions and significance: There can be cochlear dysfunction and high frequency hearing loss in diabetic patients with normal hearing thresholds of conventional frequencies. The examinations of HFA and DPOAEs are of great importance for early diagnosis of hearing loss in type 2 diabetic patients.
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [21] Association between retinal neuronal degeneration and visual function impairment in type 2 diabetic patients without diabetic retinopathy
    Zhu TiePei
    Ma Jin
    Li YongHao
    Zhang Zheng
    SCIENCE CHINA-LIFE SCIENCES, 2015, 58 (06) : 550 - 555
  • [22] Low serum apelin levels are associated with mild cognitive impairment in Type 2 diabetic patients
    Jiang, Yongli
    Wang, Shidi
    Liu, Xinghui
    BMC ENDOCRINE DISORDERS, 2022, 22 (01)
  • [23] Olfactory disfunction and diabetic complications in type 2 diabetic patients: a pilot study
    Mozzanica, Francesco
    Ferrulli, Anna
    Vujosevic, Stela
    Montuori, Alessandro
    Cardella, Arianna
    Preti, Andrea
    Ambrogi, Federico
    Schindler, Antonio
    Terruzzi, Ileana
    Ottaviani, Francesco
    Luzi, Livio
    ENDOCRINE, 2022, 75 (03) : 760 - 767
  • [24] Alteration of auditory function in type 2 diabetic and pre-diabetic patients
    Li, Jin
    Zhang, Yi
    Fu, Xinxing
    Bi, Jingtao
    Li, Yanhong
    Liu, Bo
    Zhang, Luo
    ACTA OTO-LARYNGOLOGICA, 2018, 138 (06) : 542 - 547
  • [25] Impact of different modifiable factors on hearing function in type 1 and type 2 diabetic subjects. A preliminary study
    Dabrowski, Mariusz
    Mielnik-Niedzielska, Grazyna
    Nowakowski, Andrzej
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2013, 20 (04) : 773 - 778
  • [26] Hearing impairment detection and intervention in children from centre-based early intervention programmes
    Maluleke, Ntsako P.
    Khoza-Shangase, Katijah
    Kanji, Amisha
    JOURNAL OF CHILD HEALTH CARE, 2019, 23 (02) : 232 - 241
  • [27] Use of formant centralization ratio for vowel impairment detection in normal hearing and different degrees of hearing impairment
    Naderifar, Ehsan
    Ghorbani, Ali
    Moradi, Negin
    Ansari, Hossein
    LOGOPEDICS PHONIATRICS VOCOLOGY, 2019, 44 (04) : 159 - 165
  • [28] Nursing students' knowledge of and performance in communicating with patients with hearing impairment
    Adib-Hajbaghery, Mohsen
    Rezaei-Shahsavarloo, Zahra
    JAPAN JOURNAL OF NURSING SCIENCE, 2015, 12 (02) : 135 - 144
  • [29] Cognitive impairment in type 2 diabetes patients with and without diabetic peripheral neuropathy: a mismatch negativity study
    Zhao, Lili
    Mao, Limei
    Liu, Qian
    Chen, Xiang
    Tang, Xiangdong
    An, Dongmei
    NEUROREPORT, 2021, 32 (14) : 1223 - 1228
  • [30] Hemorheological Approach for Early Detection of Chronic Kidney Disease and Diabetic Nephropathy in Type 2 Diabetes
    Lee, Seohui
    Lee, Min Young
    Nam, Ji Sun
    Kang, Shinae
    Park, Jong Suk
    Shin, Sehyun
    Ahn, Chul Woo
    Kim, Kyung Rae
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) : 808 - 815