Hemorrhagic Panniculitis Caused by Delayed Microemboli From Intravascular Device

被引:11
作者
Hardy, Curtis Lamar [1 ]
Glass, Jonathan S. [2 ]
Sorrells, Timothy [3 ]
Nicholas, Luke C. [2 ]
机构
[1] Naval Med Ctr Portsmouth, Dept Grad Med Educ, Portsmouth, VA 23708 USA
[2] Naval Med Ctr Portsmouth, Dept Dermatol, Portsmouth, VA 23708 USA
[3] Naval Med Ctr Portsmouth, Dept Pathol, Portsmouth, VA 23708 USA
关键词
EMBOLIZATION;
D O I
10.1001/jamadermatol.2014.2393
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
IMPORTANCE The breakdown of previously inserted intravascular devices can lead to microemboli that can clinically mimic the symptoms of common disorders, such as senile purpura, and have subtle histologic findings. However, device failure can occur gradually and start months after placement. If not identified early, microemboli to noncutaneous sites can cause significant morbidity and mortality. OBSERVATIONS A woman in her 70s presented 6 months after a complex aortic aneurysm repair with several large ecchymoses radiating from firm subcutaneous nodules on the buttocks, arms, and thighs. Skin biopsy specimens revealed extensive hemorrhage and a panniculitis with sparse, subtle, intra-arteriole, gray amorphous deposits that, on analysis by scanning electron microscopy with energy-dispersive radiography analysis and infrared spectrometry, were most consistent with a hydrophilic polymer. This type of hydrophilic polymer coats catheters and stents such as those used in aortic aneurysm repair. CONCLUSIONS AND RELEVANCE This is an unusual case of microemboli from the polymer coating intra-arterial stents starting months after placement and causing a panniculitis. Prior observations show that polymers coating intravascular devices have the potential to break down gradually and long after the device's placement, but clinical consideration for delayed microembolization is underrecognized until catastrophic impairment or death.
引用
收藏
页码:204 / 207
页数:4
相关论文
共 9 条
[1]   Embolization of Hydrophilic Catheter Coating to the Lungs Report of a Case Mimicking Granulomatous Vasculitis [J].
Allan, Robert W. ;
Alnuaimat, Hassan ;
Edwards, William D. ;
Tazelaar, Henry D. .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2009, 132 (05) :794-797
[2]  
[Anonymous], CARDIOVASC PATHOL
[3]   In vivo distribution of particulate matter from coated angioplasty balloon catheters [J].
Babcock, David E. ;
Hergenrother, Robert W. ;
Craig, David A. ;
Kolodgie, Frank D. ;
Virmani, Renu .
BIOMATERIALS, 2013, 34 (13) :3196-3205
[4]   Changes to Polymer Surface of Drug-Eluting Stents During Balloon Expansion [J].
Denardo, Scott J. ;
Carpinone, Paul L. ;
Vock, David M. ;
Batich, Christopher D. ;
Pepine, Carl J. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 307 (20) :2148-2150
[5]   Complications of endovascular polymers associated with vascular introducer sheaths and metallic coils in 3 patients, with literature review [J].
Fealey, Michael E. ;
Edwards, William D. ;
Giannini, Caterina ;
Piepgras, David G. ;
Cloft, Harry ;
Rihal, Charanjit S. .
AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 2008, 32 (09) :1310-1316
[6]   Hydrophilic polymer emboli: an under-recognized iatrogenic cause of ischemia and infarct [J].
Mehta, Rupal I. ;
Mehta, Rashi I. ;
Solis, Orestes E. ;
Jahan, Reza ;
Salamon, Noriko ;
Tobis, Jonathan M. ;
Yong, William H. ;
Vinters, Harry V. ;
Fishbein, Michael C. .
MODERN PATHOLOGY, 2010, 23 (07) :921-930
[7]   Polymer Embolization From Minimally Invasive Interventions [J].
Sequeira, Adrian ;
Parimoo, Nakul ;
Wilson, Jon ;
Traylor, James ;
Bonsib, Stephen ;
Abreo, Kenneth .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2013, 61 (06) :984-987
[8]  
White GH, 1998, J ENDOVASC SURG, V5, P305, DOI 10.1583/1074-6218(1998)005<0305:TIATIE>2.0.CO
[9]  
2