Radiographic outcome of limb-based versus knee-based patient specific guides in total knee arthroplasty

被引:5
作者
Crane, Catherine [1 ]
Marimuthu, Kanniraj [2 ]
Chen, Darren B. [1 ,2 ]
Harris, Ian A. [3 ]
Wheatley, Emma [4 ]
MacDessi, Samuel J. [1 ,2 ]
机构
[1] Canterbury Hosp, Dept Orthopaed Surg, Canterbury, NSW, Australia
[2] Sydney Knee Specialists, St George Private Hosp, Sydney, NSW, Australia
[3] UNSW, South Western Sydney Clin Sch, Ingham Inst Appl Med Res, Sydney, NSW, Australia
[4] St George Private Hosp, Sydney, NSW, Australia
关键词
Patient specific guides; Radiographic outcomes; Knee arthroplasty; Alignment; CT Perth protocol; ALIGNMENT; INSTRUMENTATION; REPLACEMENT; ACCURACY; SURGERY; TKA; ROTATION; SYSTEM;
D O I
10.1016/j.knee.2014.08.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patient specific guides (PSG's) were developed to improve overall component alignment in total knee arthroplasty (MA). The aim of this study was to undertake a comparative radiographic study of two commonly used PSG and determine whether the radiographic technique used to construct the PSG had a significant effect on overall alignment. Methods: This prospective cohort study examined the accuracy of limb-based (n = 112) versus knee-based (n = 105) MR PSG in restoring the mechanical axis in three planes according to post-operative Perth CT scan protocol. Results: Limb-based MR and knee-based MR PSG systems both restored overall hip-knee-ankle angle (HKAA), femoral coronal alignment, tibial coronal alignment, femoral sagittal alignment, tibial sagittal alignment and femoral rotation alignment to within 30 of a neutral mechanical axis with similar precision (91.1% vs. 86.7% p = 030, 97.3% vs. 96.2% p = 0.63, 97.3% vs. 97.1% p = 0.94,94.6% vs. 89.4% p = 0.16, 90.2% vs. 81.0% p = 0.05, 91.1% vs. 86.7% p = 0.30, respectively). However, when the secondary outcome measure of alignment within 2 was assessed, limb-based MR PSG restored HKAA, femoral coronal and tibial sagittal alignment with greater precision than knee-based MR PSG (73.2% vs. 64.8% p = 0.016, 93.8% vs. 80.8% p = 0.004 and 82.1% vs. 62.9% p = 0.001, respectively). Conclusions: The findings of this study recommend the use of limb-based MR PSG for improved precision in the restoration of neutral mechanical alignment over knee-based MR PSG in MA. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1244 / 1249
页数:6
相关论文
共 50 条
[41]   Similar radiological results with accelerometer-based navigation versus conventional technique in total knee arthroplasty [J].
Moo, Ing How ;
Chen, Jerry Yong Qiang ;
Chau, Dickson Hong Him ;
Tan, See Wei ;
Lau, Adrian Cheng Kiang ;
Teo, Yee Sze .
JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (02)
[42]   Accelerometer-Based and Computer-Assisted Navigation in Total Knee Arthroplasty: A Reduction in Mechanical Axis Outliers Does Not Lead to Improvement in Functional Outcomes or Quality of Life When Compared to Conventional Total Knee Arthroplasty [J].
Goh, Graham Seow-Hng ;
Liow, Ming Han Lincoln ;
Tay, Darren Keng-Jin ;
Lo, Ngai-Nung ;
Yeo, Seng-Jin ;
Tan, Mann-Hong .
JOURNAL OF ARTHROPLASTY, 2018, 33 (02) :379-385
[43]   Early clinical and radiological results of total knee arthroplasty using patient-specific guides in obese patients [J].
Rahij Anwar ;
Sunil Gurpur Kini ;
Saif Sait ;
Warwick J. M. Bruce .
Archives of Orthopaedic and Trauma Surgery, 2016, 136 :265-270
[44]   Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position - A radiographic analysis [J].
Maestro, A ;
Harwin, SF ;
Sandovaal, MG ;
Vaquero, DH ;
Murcia, A .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :552-558
[45]   Reliability of patient specific instrumentation in total knee arthroplasty [J].
Jennart, Harold ;
Yamben, Marie-Ange Ngo ;
Kyriakidis, Theofylaktos ;
Zorman, David .
ACTA ORTHOPAEDICA BELGICA, 2015, 81 (04) :668-672
[46]   Functional Outcome Based on Mechanical Axis Alignment Following Total Knee Arthroplasty [J].
Charaya, Himanshu ;
Gill, Harpreet S. ;
Bhan, Rahul .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (02)
[47]   Computed tomography-based patient-specific cutting guides used for positioning of the femoral component of implants during unicompartmental knee arthroplasty: a cadaver study [J].
Cai, Junfeng ;
Ma, Min ;
Zeng, Wen ;
Luo, Shuling ;
Yuan, Feng ;
Yin, Feng .
BMC SURGERY, 2023, 23 (01)
[48]   Patient-reported outcome after patient-specific unicondylar knee arthroplasty for unicompartmental knee osteoarthritis [J].
Freigang, Viola ;
Rupp, Markus ;
Pfeifer, Christian ;
Worlicek, Michael ;
Radke, Stefan ;
Deckelmann, Stephan ;
Alt, Volker ;
Baumann, Florian .
BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
[49]   Posterior tibial slope accuracy with patient-specific cutting guides during total knee arthroplasty: A preliminary study of 50 cases [J].
Schlatterer, B. ;
Linares, J. -M. ;
Cazal, J. ;
Merloz, P. ;
Plaweski, S. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (06) :S233-S240
[50]   Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation [J].
Schotanus, Martijn G. M. ;
Thijs, Elke ;
Boonen, B. ;
Kerens, B. ;
Jong, B. ;
Kort, Nanne P. .