Radiographic outcome of limb-based versus knee-based patient specific guides in total knee arthroplasty

被引:5
作者
Crane, Catherine [1 ]
Marimuthu, Kanniraj [2 ]
Chen, Darren B. [1 ,2 ]
Harris, Ian A. [3 ]
Wheatley, Emma [4 ]
MacDessi, Samuel J. [1 ,2 ]
机构
[1] Canterbury Hosp, Dept Orthopaed Surg, Canterbury, NSW, Australia
[2] Sydney Knee Specialists, St George Private Hosp, Sydney, NSW, Australia
[3] UNSW, South Western Sydney Clin Sch, Ingham Inst Appl Med Res, Sydney, NSW, Australia
[4] St George Private Hosp, Sydney, NSW, Australia
关键词
Patient specific guides; Radiographic outcomes; Knee arthroplasty; Alignment; CT Perth protocol; ALIGNMENT; INSTRUMENTATION; REPLACEMENT; ACCURACY; SURGERY; TKA; ROTATION; SYSTEM;
D O I
10.1016/j.knee.2014.08.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patient specific guides (PSG's) were developed to improve overall component alignment in total knee arthroplasty (MA). The aim of this study was to undertake a comparative radiographic study of two commonly used PSG and determine whether the radiographic technique used to construct the PSG had a significant effect on overall alignment. Methods: This prospective cohort study examined the accuracy of limb-based (n = 112) versus knee-based (n = 105) MR PSG in restoring the mechanical axis in three planes according to post-operative Perth CT scan protocol. Results: Limb-based MR and knee-based MR PSG systems both restored overall hip-knee-ankle angle (HKAA), femoral coronal alignment, tibial coronal alignment, femoral sagittal alignment, tibial sagittal alignment and femoral rotation alignment to within 30 of a neutral mechanical axis with similar precision (91.1% vs. 86.7% p = 030, 97.3% vs. 96.2% p = 0.63, 97.3% vs. 97.1% p = 0.94,94.6% vs. 89.4% p = 0.16, 90.2% vs. 81.0% p = 0.05, 91.1% vs. 86.7% p = 0.30, respectively). However, when the secondary outcome measure of alignment within 2 was assessed, limb-based MR PSG restored HKAA, femoral coronal and tibial sagittal alignment with greater precision than knee-based MR PSG (73.2% vs. 64.8% p = 0.016, 93.8% vs. 80.8% p = 0.004 and 82.1% vs. 62.9% p = 0.001, respectively). Conclusions: The findings of this study recommend the use of limb-based MR PSG for improved precision in the restoration of neutral mechanical alignment over knee-based MR PSG in MA. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1244 / 1249
页数:6
相关论文
共 50 条
[31]   Accuracy and efficacy of osteotomy in total knee arthroplasty with patient-specific navigational template [J].
Gan, Yudong ;
Ding, Jing ;
Xu, Yongqing ;
Hou, Chunlin .
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (08) :12192-12201
[32]   Preoperative corrections are required for planning of patient-specific instrumentation in total knee arthroplasty [J].
Okada, Yohei ;
Teramoto, Atsushi ;
Suzuki, Tomoyuki ;
Kii, Yuichiro ;
Watanabe, Kota ;
Yamashita, Toshihiko .
KNEE, 2017, 24 (06) :1492-1497
[33]   Patient-Specific Instrumentation Affects Perioperative Blood Loss in Total Knee Arthroplasty [J].
Cucchi, Davide ;
Menon, Alessandra ;
Zanini, Beatrice ;
Compagnoni, Riccardo ;
Ferrua, Paolo ;
Randelli, Pietro .
JOURNAL OF KNEE SURGERY, 2019, 32 (06) :483-489
[34]   Artificial Intelligence Based Patient-Specific Preoperative Planning Algorithm for Total Knee Arthroplasty [J].
Lambrechts, Adriaan ;
Wirix-Speetjens, Roel ;
Maes, Frederik ;
Van Huffel, Sabine .
FRONTIERS IN ROBOTICS AND AI, 2022, 9
[35]   Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study [J].
Kotela, Andrzej ;
Kotela, Ireneusz .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (10) :2099-2107
[36]   Safe and Accurate Utilization of Patient-specific Guides in Total Knee Arthroplasty [J].
Patel, Anay R. ;
Ghate, Raju ;
Stulberg, Samuel David .
TECHNIQUES IN ORTHOPAEDICS, 2013, 28 (02) :191-199
[37]   CT- versus MRI-based patient-specific instrumentation for total knee arthroplasty: A systematic review and meta-analysis [J].
Wu, Xiang-Dong ;
Xiang, Bing-Yan ;
Schotanus, Martijn G. M. ;
Liu, Zun-Han ;
Chen, Yu ;
Huang, Wei .
SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2017, 15 (06) :336-348
[38]   A radiological analysis of the difference between MRI- and CT-based patient-specific matched guides for total knee arthroplasty from the same manufacturer A RANDOMISED CONTROLLED TRIAL [J].
Schotanus, M. G. M. ;
Sollie, R. ;
van Haaren, E. H. ;
Hendrickx, R. P. M. ;
Jansen, E. J. P. ;
Kort, N. P. .
BONE & JOINT JOURNAL, 2016, 98B (06) :786-792
[39]   Accuracy of Patient Specific Cutting Blocks in Total Knee Arthroplasty [J].
Helmy, Naeder ;
Mai Lan Dao Trong ;
Kuehnel, Stefanie P. .
BIOMED RESEARCH INTERNATIONAL, 2014, 2014
[40]   Total knee arthroplasty: Limb length discrepancy and functional outcome [J].
Vaidya, Shrinand V. ;
Patel, Mihir R. ;
Panghate, Atul N. ;
Rathod, Parthiv A. .
INDIAN JOURNAL OF ORTHOPAEDICS, 2010, 44 (03) :300-307