Mechanical Properties of the Stellite 6 Cobalt Alloy Implanted with Nitrogen Ions

被引:10
|
作者
Budzynski, P. [1 ]
Kaminski, M. [1 ]
Wiertel, M. [2 ]
Pyszniak, K. [2 ]
Drozdziel, A. [2 ]
机构
[1] Lublin Univ Technol, Fac Mech Engn, Nadbystrzycka 36, PL-20618 Lublin, Poland
[2] M Curie Sklodowska Univ, Inst Phys, Pl M Curie Sklodowskiej 1, PL-20031 Lublin, Poland
关键词
TRIBOLOGICAL PROPERTIES; TOOL STEEL; IMPROVEMENT;
D O I
10.12693/APhysPolA.132.203
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The effect of nitrogen ion implantation on Stellite 6 cobalt alloy was investigated. In this research, cobalt alloy was implanted with 65 keV nitrogen ions at the fluence of (1 divided by 10) X 10(16) N+/cm(2). The distribution of implanted nitrogen ions and vacancies produced by them was calculated using the SRIM program. The surface morphology was examined and the elemental analysis was performed using scanning electron microscopy, energy dispersive X-ray spectroscopy and grazing incidence X-ray diffraction. The wear tests were conducted with the use of the pin-on-disc method. The results demonstrate that implantation with nitrogen ions significantly reduces the friction factor and wear. The friction coefficient of the implanted sample at the fluence of 1 x 10(17) N+/cm(2) increased to the values characteristic of an unimplanted sample after 5000 measurement cycles. The depth of the worn trace was about 2.0 mu m. This implies that the thickness of the layer modified by the implantation process is approximate to 2.0 mu m and exceeds the initial range of the implanted ions by an order of magnitude. This is referred to as a long-range implantation effect. The investigations have shown that the long-range effect is caused by movement of not only implanted nitrogen atoms but also carbon dopant atoms towards the friction zone. Diffusion of carbon atoms has been documented here for the first time. Furthermore, the increased content of oxygen atoms on the track bottom indicates a dominant oxidative wear of the Stellite samples after nitrogen implantation with the energy 65 keV and the fluences of 5 x 10(16) and 10(17) N+/cm(2)
引用
收藏
页码:203 / 205
页数:3
相关论文
共 50 条
  • [1] Tribological properties of the Stellite 6 cobalt alloy implanted with manganese ions
    Kaminski, M.
    Budzynski, P.
    Szala, M.
    Turek, M.
    INTERNATIONAL AUTOMOTIVE CONFERENCE (KONMOT2018), 2018, 421
  • [2] Comparing of Microhardness of the Stellite 6 Cobalt Alloy Implanted with 175 keV Mn+ Ions and 120 keV N+ Ions
    Kaminski, Mariusz
    Budzynski, Piotr
    Szala, Miroslaw
    Turek, Marcin
    ADVANCES IN SCIENCE AND TECHNOLOGY-RESEARCH JOURNAL, 2019, 13 (03) : 179 - 185
  • [3] ELECTROCHEMICAL AND MECHANICAL-PROPERTIES OF ALLOY-STEELS IMPLANTED BY NITROGEN-IONS
    CERNY, F
    PRAZAK, M
    SUCHANEK, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 59 : 762 - 763
  • [4] Impact of nitrogen and manganese ion implantation on the tribological properties of Stellite 6 alloy
    Budzynski, P.
    Kaminski, M.
    Turek, M.
    Wiertel, M.
    WEAR, 2020, 456
  • [5] Microstructure and mechanical properties of chromium thin film implanted with nitrogen ions
    Manouchehrian, Mehdi
    Larijani, Majid Mojtahedzadeh
    Banagar, Bahman
    INTERNATIONAL JOURNAL OF SURFACE SCIENCE AND ENGINEERING, 2015, 9 (05) : 407 - 414
  • [6] MECHANICAL AND ELECTROCHEMICAL PROPERTIES OF VARIOUS TOOL STEELS IMPLANTED WITH NITROGEN OR NO IONS
    IWAKI, M
    FUJIHANA, T
    OKITAKA, K
    MATERIALS SCIENCE AND ENGINEERING, 1985, 69 (01): : 211 - 217
  • [7] The Effect of Fe on the Mechanical Properties of Stellite 6
    Baek, Min Ah
    Kang, Gyu Byeong
    Suk, Gyeong Chan
    Hong, Seong Chan
    Kim, Young Do
    Na, Tae-Wook
    METALS, 2024, 14 (02)
  • [8] The influence of nitrogen ion implantation on microhardness of the Stellite 6 alloy
    Budzynski, P.
    Kaminski, M.
    Palka, K.
    Drozdziel, A.
    Wiertel, M.
    SCIENTIFIC CONFERENCE ON AUTOMOTIVE VEHICLES AND COMBUSTION ENGINES (KONMOT 2016), 2016, 148
  • [9] Phenomenological Model of Cavitation Erosion of Nitrogen ION Implanted Hiped Stellite 6
    Szala, Miroslaw
    ADVANCES IN MATERIALS SCIENCE, 2023, 23 (01): : 98 - 109
  • [10] Mechanical properties and structure of Ti-6Al-4V alloy implanted with different light ions
    Alonso, F.
    Arizaga, A.
    Quainton, S.
    Ugarte, J. J.
    Viviente, J. L.
    Onate, J. I.