Data quality, issues, and guidelines for electrochemical corrosion potential measurement in high-temperature water

被引:63
作者
Kim, YJ [1 ]
Andresen, PL [1 ]
机构
[1] GE Global Res Ctr, Schenectady, NY 12309 USA
关键词
electrochemical corrosion potential; flow rate; high-temperature water; hydrogen; impurities; oxygen; reference electrode; stainless steel;
D O I
10.5006/1.3277589
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The electrochemical corrosion potential (ECP) of a metal is influenced by a large number of variables, such as oxygen, hydrogen, and hydrogen peroxide (H2O2) concentrations, the surface chemistry, impurities, hydrodynamic flow conditions, type of reference electrode, etc. The state of reference electrode development and qualification, water chemistry conditioning procedures, surface history, etc. is such that achieving total agreement from all international investigators is difficult. However, identification of key factors, preferred techniques, and sensible ranges in potentials for several standard conditions is possible. The purpose of this paper is to identify factors that influence ECP measurements in high-temperature water, propose recommended techniques, and characterize the expected range of corrosion potentials for specific materials, dissolved gas chemistries, water chemistry/pH, and temperature associated with boiling water reactor (BWR), pressurized water reactor (PWR), and related high-temperature water environments.
引用
收藏
页码:584 / 596
页数:13
相关论文
共 50 条
  • [21] Application of insulated protective coatings for reduction of corrosion potential of type 304 stainless steel in high-temperature water
    Kim, YJ
    Andresen, PL
    CORROSION, 1998, 54 (12) : 1012 - 1017
  • [22] General corrosion and stress corrosion cracking behaviors of Alloy 825 in high-temperature supercritical water
    Chen, Hongsheng
    Tang, Rui
    Wei, Tianguo
    Leng, Xuesong
    CORROSION SCIENCE, 2025, 250
  • [23] The repassivation kinetics study of Alloy 800 in high-temperature pressurized water
    Wang, Jiazhen
    Han, En-Hou
    Wang, Jianqiu
    ELECTROCHEMISTRY COMMUNICATIONS, 2015, 60 : 100 - 103
  • [24] In-situ electrochemical impedance measurement of oxide film formed on Type 304 stainless steel in high-temperature water
    Kim, YJ
    CORROSION, 2000, 56 (04) : 389 - 394
  • [25] Hydrogen isotopic effect during the graphite high-temperature corrosion in water vapours
    Chikhray, Yevgen
    Askerbekov, Saulet
    Kenzhina, Inesh
    Gordienko, Yuriy
    Bochkov, Vadim
    Nesterov, Evgeny
    Varlamova, Natalia
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (55) : 29365 - 29370
  • [26] Nonisothermal electrochemical cell for monitoring hydrogen or oxygen in high temperature water
    D.R. Morris
    Fang Jiang
    J.M. McINERNEY
    D.H. Lister
    Journal of Applied Electrochemistry, 1999, 29 : 971 - 977
  • [27] Nonisothermal electrochemical cell for monitoring hydrogen or oxygen in high temperature water
    Morris, DR
    Jiang, F
    McInerney, JM
    Lister, DH
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 1999, 29 (08) : 971 - 977
  • [28] Effect of neutron irradiation on stress corrosion cracking of sensitized type 304 stainless steel in high-temperature water
    Mayuzumi, M
    Hide, K
    Arai, T
    CORROSION, 2001, 57 (03) : 214 - 220
  • [29] Corrosion Fatigue Behavior of 316LN Stainless Steel Hollow Specimen in High-Temperature Pressurized Water
    Tan Jibo
    Wang Xiang
    Wu Xinqiang
    Han En-Hou
    ACTA METALLURGICA SINICA, 2021, 57 (03) : 309 - 316
  • [30] Stress corrosion crack initiation testing with tapered specimens in high-temperature water - results of a collaborative research project
    Bosch, Rik-Wouter
    Ritter, Stefan
    Herbst, Matthias
    Kilian, Renate
    Burke, M. Grace
    Duff, Jonathan
    Scenini, Fabio
    Gu, Yuchen
    Dinu, Alice
    Ehrnsten, Ulla
    Toivonen, Aki
    Novotny, Radek
    Martin, Oliver
    Perosanz, Francisco-Javier
    Legat, Andraz
    Zajec, Bojan
    CORROSION ENGINEERING SCIENCE AND TECHNOLOGY, 2021, 56 (02) : 103 - 118