Determining C2 Pedicle Screw Placement Feasibility in the Pediatric Population: A Computed Tomographic Safe Zone Analysis

被引:1
|
作者
Hirase, Takashi [1 ]
Wu Zhuge [2 ]
Phelps, Christopher, I [2 ]
Kushwaha, Vivek P. [2 ]
Marco, Rex A. W. [1 ]
机构
[1] Houston Methodist Hosp, Dept Orthoped & Sports Med, 6445 Main St,Suite 2500, Houston, TX 77030 USA
[2] Univ Texas Houston, Dept Orthopaed Surg, Hlth Sci Ctr, Houston, TX USA
关键词
C2; pedicle screws; pedicle; feasibility; cervical; imaging; computer tomography; C1 LATERAL MASS; VERTEBRAL ARTERY; BIOMECHANICAL EVALUATION; AXIS VERTEBRA; SUITABILITY; COMPLEX;
D O I
10.1097/BPO.0000000000001938
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Due to high rates of anatomic variability of the C2 pedicle, thin-sliced pedicular-oriented computed tomography (CT) and 3-dimensional reconstructive CT technologies have been introduced to predict safe C2 pedicle screw placement. However, this technology may not be readily available in all centers. The purpose of this study was to perform a C2 pedicle safe zone analysis using standard sagittal CT scans to predict the feasibility of C2 pedicle screw placement in a pediatric population and to compare the results with our previously obtained safe zone analysis from the adult population. Methods: A retrospective analysis was performed at a single level I trauma center of pediatric patients who completed CT scans of the cervical spine. The feasibility of C2 pedicle screw placement was analyzed using our previously described C2 pedicle safe zone analysis technique. The risk profiles were compared with our previously obtained safe zone analysis from the adult population. Results: Thirty-nine consecutive patients with a mean age of 7.8 +/- 4.4 years and 78 total pedicles were included in the study. Fourteen pedicles (18%) were considered low risk, 37 (47%) were moderate risk, and 27 (35%) were high risk for vertebral artery injury. Individual patients were found to have a significant amount of side-to-side variability between pedicles with 21 patients (54%) having left and right pedicles with different risk profiles. Four patients (10%) demonstrated low risk profiles in bilateral pedicles. There was no significant difference between the risk profiles of pediatric and adult patients. Conclusions: There is a considerable amount of anatomic variability within the pediatric C2 pedicles. Using this simple and accessible technique during the review of preoperative imaging, C2 pedicle screw placement may be considered in appropriately selected pediatric patients.
引用
收藏
页码:580 / 584
页数:5
相关论文
共 50 条
  • [41] "Inline" Axial Reconstructed CT Scans Provide a Significantly Larger Assessment of C2 Pedicle Diameter for Screw Placement Compared With "Standard" Axial Scans Implications for Surgical Planning
    Vizurraga, David E.
    Rhee, John M.
    Borden, Timothy C.
    Mansour, Ashton S.
    CLINICAL SPINE SURGERY, 2017, 30 (08): : E1039 - E1045
  • [42] Characteristics and Comparisons of Morphometric Measurements and Computed Tomography Hounsfield Unit Values of C2 Laminae for Translaminar Screw Placement Between Patients With and Without Basilar Invagination
    Zhou, Lu-Ping
    Shang, Jin
    Zhang, Zhi-Gang
    Jiang, Zhen-Fei
    Zhang, Hua-Qing
    Jia, Chong-Yu
    Zhang, Ren-Jie
    Shen, Cai-Liang
    NEUROSPINE, 2022, 19 (04) : 899 - +
  • [43] A Comparative Study of C2 Pedicle or Pars Screw Placement with Assistance from a 3-Dimensional (3D)-Printed Navigation Template versus C-Arm Based Navigation
    Tian, Ye
    Zhang, Jianan
    Liu, Tuanjiang
    Tang, Shi
    Chen, Hao
    Ding, Keyuan
    Hao, Dingjun
    MEDICAL SCIENCE MONITOR, 2019, 25 : 9981 - 9990
  • [44] Comparison of Screw Malposition and Vertebral Artery Injury of C2 Pedicle and Transarticular Screws Meta-Analysis and Review of the Literature
    Elliott, Robert E.
    Tanweer, Omar
    Boah, Akwasi
    Morsi, Amr
    Ma, Tracy
    Frempong-Boadu, Anthony
    Smith, Michael L.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (06): : 305 - 315
  • [45] Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for C1 Lateral Mass and C2 Pedicle Screw Placement for Atlantoaxial Instability
    Yang, Yong Liang
    Zhou, Dong Sheng
    He, Ji Liang
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (03): : 127 - 134
  • [46] Accuracy and Safety in Screw Placement in the High Cervical Spine Retrospective Analysis of O-arm-based Navigation-assisted C1 Lateral Mass and C2 Pedicle Screws
    Hur, Jung-Woo
    Kim, Jin-Sung
    Ryu, Kyeong-Sik
    Shin, Myeong-Hoon
    CLINICAL SPINE SURGERY, 2019, 32 (04): : E193 - E199
  • [47] Deviation analysis for C1/2 pedicle screw placement using a three-dimensional printed drilling guide
    Wu, Xinghuo
    Liu, Rong
    Yu, Jie
    Lu, Lin
    Yang, Cao
    Shao, Zengwu
    Ye, Zhewei
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (06) : 547 - 554
  • [48] Long-Term Influence of C1-C2 Pedicle Screw Fixation on Occipitoatlantal Angle and Subaxial Cervical Spine in the Pediatric Population
    Tang, Xiangsheng
    Dong, Liang
    Tan, Mingsheng
    Yi, Ping
    Yang, Feng
    Hao, Qingying
    PEDIATRIC NEUROSURGERY, 2018, 53 (03) : 143 - 148
  • [49] Evaluation of Multi-Slice Spiral Computed Tomography i n In vivo Simulation of Individualized Cervical Pedicle Screw Placement at C3-C7 in Chinese Healthy Population
    Chen, Wei
    Fang, Xiang-Ming
    Qian, Ping-Yan
    Kumar, Sanjeev P. S.
    Chen, Hong-wei
    Hu, Xiao-Yun
    INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (06) : 651 - 656
  • [50] Radiographic and clinical assessment on the accuracy and complications of C1 anterior lateral mass and C2 anterior pedicle screw placement in the TARP-III procedure: a study of 106 patients
    Xueshi Li
    Fuzhi Ai
    Hong Xia
    Zenghui Wu
    Xiangyang Ma
    Qingshui Yin
    European Spine Journal, 2014, 23 : 1712 - 1719