Determining C2 Pedicle Screw Placement Feasibility in the Pediatric Population: A Computed Tomographic Safe Zone Analysis

被引:1
|
作者
Hirase, Takashi [1 ]
Wu Zhuge [2 ]
Phelps, Christopher, I [2 ]
Kushwaha, Vivek P. [2 ]
Marco, Rex A. W. [1 ]
机构
[1] Houston Methodist Hosp, Dept Orthoped & Sports Med, 6445 Main St,Suite 2500, Houston, TX 77030 USA
[2] Univ Texas Houston, Dept Orthopaed Surg, Hlth Sci Ctr, Houston, TX USA
关键词
C2; pedicle screws; pedicle; feasibility; cervical; imaging; computer tomography; C1 LATERAL MASS; VERTEBRAL ARTERY; BIOMECHANICAL EVALUATION; AXIS VERTEBRA; SUITABILITY; COMPLEX;
D O I
10.1097/BPO.0000000000001938
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Due to high rates of anatomic variability of the C2 pedicle, thin-sliced pedicular-oriented computed tomography (CT) and 3-dimensional reconstructive CT technologies have been introduced to predict safe C2 pedicle screw placement. However, this technology may not be readily available in all centers. The purpose of this study was to perform a C2 pedicle safe zone analysis using standard sagittal CT scans to predict the feasibility of C2 pedicle screw placement in a pediatric population and to compare the results with our previously obtained safe zone analysis from the adult population. Methods: A retrospective analysis was performed at a single level I trauma center of pediatric patients who completed CT scans of the cervical spine. The feasibility of C2 pedicle screw placement was analyzed using our previously described C2 pedicle safe zone analysis technique. The risk profiles were compared with our previously obtained safe zone analysis from the adult population. Results: Thirty-nine consecutive patients with a mean age of 7.8 +/- 4.4 years and 78 total pedicles were included in the study. Fourteen pedicles (18%) were considered low risk, 37 (47%) were moderate risk, and 27 (35%) were high risk for vertebral artery injury. Individual patients were found to have a significant amount of side-to-side variability between pedicles with 21 patients (54%) having left and right pedicles with different risk profiles. Four patients (10%) demonstrated low risk profiles in bilateral pedicles. There was no significant difference between the risk profiles of pediatric and adult patients. Conclusions: There is a considerable amount of anatomic variability within the pediatric C2 pedicles. Using this simple and accessible technique during the review of preoperative imaging, C2 pedicle screw placement may be considered in appropriately selected pediatric patients.
引用
收藏
页码:580 / 584
页数:5
相关论文
共 50 条
  • [1] Freehand technique for C2 pedicle and pars screw placement: is it safe?
    Punyarat, Prachya
    Buchowski, Jacob M.
    Klawson, Benjamin T.
    Peters, Colleen
    Lertudomphonwanit, Thamrong
    Riew, K. Daniel
    SPINE JOURNAL, 2018, 18 (07) : 1197 - 1203
  • [2] Radiologic Analysis of C2 to Predict Safe Placement of Pedicle Screws
    Marco, Rex A. W.
    Phelps, Christopher I.
    Kuo, Rebecca C.
    Wu Zhuge
    Howard, Clinton W.
    Kushwaha, Vivek P.
    Bernstein, Derek T.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2018, 12 (01): : 30 - 36
  • [3] Planning C2 pedicle screw placement with multiplanar reformatted cervical spine computed tomography
    Davidson, Casey T.
    Bergin, Patrick F.
    Varney, Elliot T.
    Jones, LaRita C.
    Ward, Marion S.
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2019, 10 (01) : 46 - 50
  • [4] Computed Tomographic Morphometric Analysis of C1 and C2 for Lamina Cross Screw Placement in Malay Ethnicity
    Chan, Allan Kah Hay
    Yusof, Mohd Imran
    Abdullah, Mohd Shafie
    ASIAN SPINE JOURNAL, 2021, 15 (01) : 1 - 8
  • [5] Accuracy of C2 pedicle screw placement using the anatomic freehand technique
    Bydon, Mohamad
    Mathios, Dimitrios
    Macki, Mohamed
    De la Garza-Ramos, Rafael
    Aygun, Nafi
    Sciubba, Daniel M.
    Witham, Timothy F.
    Gokaslan, Ziya L.
    Bydon, Ali
    Wolinksy, Jean-Paul
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2014, 125 : 24 - 27
  • [6] Proposal of a New Safety Margin for Placement of C2 Pedicle Screws on Computed Tomography Angiography
    Agrawal, Mohit
    Devarajan, Leve J.
    Singh, Pankaj K.
    Garg, Ajay
    Kale, Shashank S.
    WORLD NEUROSURGERY, 2018, 120 : E282 - E289
  • [7] Safety and accuracy of freehand versus navigated C2 pars or pedicle screw placement
    Hlubek, Randall J.
    Bohl, Michael A.
    Cole, Tyler S.
    Morgan, Clinton D.
    Xu, David S.
    Chang, Steve W.
    Turner, Jay D.
    Kakarla, U. Kumar
    SPINE JOURNAL, 2018, 18 (08) : 1374 - 1381
  • [8] Anatomical Study of the Posterior Ascending Artery: Application to C2 Pedicle Screw Placement
    Iwanaga, Joe
    Simonds, Emily
    Choi, Paul J.
    Oskouian, Rod J.
    Tubbs, R. Shane
    WORLD NEUROSURGERY, 2018, 112 : E662 - E665
  • [9] Evaluation of C2 pedicle screw placement via the freehand technique by neurosurgical trainees
    Pham, Martin H.
    Bakhsheshian, Joshua
    Reid, Patrick C.
    Buchanan, Ian A.
    Fredrickson, Vance L.
    Liu, John C.
    JOURNAL OF NEUROSURGERY-SPINE, 2018, 29 (03) : 235 - 240
  • [10] Reformatted computed tomographic evaluation of the thoracic pedicle in a Chinese population for the surgical application of transpedicular screw placement
    Chen, Yuchun
    Zeng, Jican
    Guan, Jitian
    Guo, Yuelin
    Wang, Xinjia
    Yao, Guanfeng
    Wang, Weidong
    Qi, Weili
    Kong, Kangmei
    SURGICAL AND RADIOLOGIC ANATOMY, 2010, 32 (05) : 463 - 468