Sol-gel-derived graphite organosilicate composite electrodes bulk-modified with Keggin-type α-germanomolybdic acid

被引:44
|
作者
Wang, P
Yuan, Y
Han, ZB
Zhu, GY [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, Electroanalyt Chem Lab, Changchun 130022, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Appl Chem, Natl Analyt Res Ctr Electrochem & Spect, Changchun 130022, Peoples R China
[3] NE Normal Univ, Dept Chem, Changchun 130024, Peoples R China
关键词
D O I
10.1039/b006559p
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A novel inorganic-organic hybrid material incorporating graphite powder and Keggin-type alpha -germanomolybdic acid (GeMo12) in methyltrimethoxysilane-based gels has been produced by the sol-gel technique and used to fabricate a chemically bulk-modified electrode. GeMo12 acts as a catalyst, graphite powder ensures conductivity by percolation, the silicate provides a rigid porous backbone, and the methyl groups endow hydrophobicity and thus limit the wetting section of the modified electrode. The GeMo12-modified graphite organosilicate composite electrode was characterized by cyclic and square-wave voltammetry. The modified electrode shows a high electrocatalytic activity toward the reduction of bromate, nitrite and hydrogen peroxide in acidic aqueous solution. In addition, the chemically-modified electrode has some distinct advantages over the traditional polyoxometalate-modified electrodes, such as long-term stability and especially repeatability of surface-renewal by simple mechanical polishing.
引用
收藏
页码:549 / 553
页数:5
相关论文
共 25 条
  • [11] Sol-gel derived, silicate-phthalocyanine functionalized exfoliated graphite based composite electrodes
    Somashekarappa, MP
    Sampath, S
    ANALYTICA CHIMICA ACTA, 2004, 503 (02) : 195 - 201
  • [12] Renewable-surface amperometric nitrite sensor based on sol-gel-derived silicomolybdate-methylsilicate-graphite composite material
    Wang, P
    Wang, XP
    Bi, LH
    Zhu, GY
    ANALYST, 2000, 125 (07) : 1291 - 1294
  • [13] Surface-renewable graphite organosilicate composite electrode bulk-modified with a bifunctional electrocatalyst containing tris(2,2′-bipyridine) ruthenium(II) and 18-molybdosulfate
    Wang, XL
    Zhang, Q
    Han, ZB
    Wang, EB
    Guo, YQ
    Hu, CW
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 563 (02) : 221 - 227
  • [14] FT-IR spectroscopic investigations on sol-gel-derived coatings from acid-modified titanium alkoxides
    Urlaub, R
    Posset, U
    Thull, R
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2000, 265 (03) : 276 - 284
  • [15] Sol-gel-derived composite antimony-doped, tin oxide-coated clay-silicate semitransparent and conductive electrodes
    Sadeh, A.
    Sladkevich, S.
    Gelman, F.
    Prikhodchenko, P.
    Baumberg, I.
    Berezin, O.
    Lev, O.
    ANALYTICAL CHEMISTRY, 2007, 79 (14) : 5188 - 5195
  • [16] Amperometric detection of periodate using a graphite electrode modified with a novel α-Keggin-type silicotungstic acid salt and determination of ethylene glycol in antifreeze fluids
    Prodromidis, MI
    Veltsistas, PG
    Efstathiou, CE
    Karayannis, MI
    ELECTROANALYSIS, 2001, 13 (11) : 960 - 966
  • [17] Sol-gel derived, ferrocenyl-modified silicate-graphite composite electrode: Wiring of glucose oxidase
    Gun, J
    Lev, O
    ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) : 95 - 106
  • [18] Sol-gel derived, ferrocenyl-modified silicate-graphite composite electrode: Wiring of glucose oxidase
    Gun, J.
    Lev, O.
    1996, (336)
  • [19] Fabrication and electrochemical behavior of vanadium-substituted keggin-type polyoxometalates multilayer films on 4-aminobenzoic acid modified glassy carbon electrodes
    Li, Chunxiang
    Wang, Xiaoguang
    Ma, Huiyuan
    Wang, Fuping
    Gu, Ying
    ELECTROANALYSIS, 2008, 20 (10) : 1110 - 1115
  • [20] Electrochemical oxidation of NADH on sol-gel derived, surface renewable, non-modified and mediator modified composite-carbon electrodes
    Sampath, S
    Lev, O
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 446 (1-2) : 57 - 65