Operation regimes and heat transfer coefficients in sodium two-phase thermosyphons

被引:36
作者
Cisterna, Luis H. R. [1 ]
Cardoso, Maria C. K. [1 ]
Fronza, Eduardo L. [1 ]
Milanez, Fernando H. [1 ]
Mantelli, Marcia B. H. [1 ]
机构
[1] Univ Fed Santa Catarina, Heat Pipe Lab, BR-88040900 Florianopolis, SC, Brazil
关键词
Sodium; Two-phase thermosyphon; High temperature; Geyser Boiling; Nucleate pool boiling; Film condensation; GEYSER BOILING PHENOMENON; THERMAL PERFORMANCE; CLOSED THERMOSIPHON; PIPE; LOOP; STARTUP; REACTOR;
D O I
10.1016/j.ijheatmasstransfer.2020.119555
中图分类号
O414.1 [热力学];
学科分类号
摘要
The dry-out, cold tip and Geyser Boiling phenomena are highly undesirable in projects involving two-phase thermosyphons with sodium as working fluid. Therefore, for the application of this technology, mathematical models that allow for the prediction of the behavior of sodium two-phase thermosyphon are highly desirable. The present work aims to study the influence of the filling ratio on several phenomena, such as dry-out, cold tip, Geyser Boiling and evaporator wall overheating, so that the thermosyphon overall performance can be accessed. In addition, a correlation is proposed for the heat transfer coefficient of sodium under nucleate pool boiling regime. A correlation for the film condensation heat transfer coefficient, based on the experimental data obtained in this work, is also proposed. The results show that the proposed correlations allow for the determination, with reasonable accuracy, of the heat transfer coefficients in the evaporator and in the condenser, considering the undesired effects of cold tip and Geyser Boiling. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:15
相关论文
共 61 条
[1]  
Abreu S.L., 2003, P ISES SOL WORLD C G, P14
[2]  
Adkins D.R., 1994, SAND942059C
[3]   Experimental investigation of the influence of the geyser boiling phenomenon on the thermal performance of a two-phase closed thermosyphon [J].
Alammar, Ahmed A. ;
Al-Dadah, Raya K. ;
Mahmoud, Saad M. .
JOURNAL OF CLEANER PRODUCTION, 2018, 172 :2531-2543
[4]  
Albertazzi Armando., 2008, Fundamentos de Metrologia Cientifica e Industrial, V1st
[5]  
Andraka C., 1992, SAND941758C
[6]  
Andraka C., 1994, SAND942682C
[7]  
Andraka C., 1992, SAND900268C
[8]  
[Anonymous], 2013, Wiley Chaper, DOI DOI 10.1002/9781118671627
[9]  
[Anonymous], 1992, HEAT TRANSFER CONDEN
[10]   An experimental study on a sodium loop-type heat pipe for thermal transport from a high-temperature solar receiver [J].
Boo, J. H. ;
Kim, S. M. ;
Kang, Y. H. .
INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, SOLARPACES 2014, 2015, 69 :608-617