Thermal performance in solar air heater with perforated-winglet-type vortex generator

被引:114
作者
Skullong, Sompol [1 ]
Promthaisong, Pitak [2 ]
Promvonge, Pongjet [3 ]
Thianpong, Chinaruk [3 ]
Pimsarn, Monsak [3 ]
机构
[1] Kasetsart Univ, Fac Engn Sriracha, Dept Mech Engn, Energy Syst Res Grp, Sriracha Campus,199 M6,Sukhumvit Rd, Sriracha 20230, Chonburi, Thailand
[2] Mahanakorn Univ Technol, Fac Engn, Dept Mech Engn, Bangkok 10530, Thailand
[3] King Mongkuts Inst Technol Ladlcrabang, Fac Engn, Dept Mech Engn, Bangkok 10520, Thailand
关键词
Solar air heater; Vortex generators; Absorber plate; Nusselt number; Thermal performance; TRANSFER ENHANCEMENT; TRANSFER AUGMENTATION; EVALUATION CRITERIA; TRANSFER SURFACES; ABSORBER PLATE; CHANNEL; FRICTION; ROUGHNESS; DUCT; ARRANGEMENT;
D O I
10.1016/j.solener.2018.05.093
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An experimental and numerical study of turbulent convective heat transfer in a solar air heater duct with winglet-type vortex generators (WVGs) placed on the absorber plate is presented. Air as the test fluid enters the duct having a uniform wall heat-flux applied on the upper wall or the absorber plate with Reynolds number from 4100 to 25,500. Two types of WVGs are introduced: rectangular (RWVG) and trapezoidal (TWVG) WVGs, in order to create multiple vortex flows along the duct. The WVG parameters in the present study include two relative height (B-R = e/H = 0.2 and 0.48), three longitudinal pitch ratios (P-R = P-1/H = 1, 1.5 and 2) and a single attack angle, alpha = 30 degrees. The experimental result reveals that the RWVG with B-R = 0.48 and P-R = 1 provides the highest heat transfer and friction factor at about 7.1 and 109.5 times above the flat duct, respectively while the TWVG with B-R = 0.2 and P-R = 1.5 yields the maximum thermal performance around 1.84. Then, to improve the performance by reducing the substantial pressure loss, both the WVGs with B-R = 0.48 and P-R = 1.5 are modified to be perforated rectangular and trapezoidal winglet-type vortex generators (P-RWVG and P-TWVG) with four different punched hole/pore diameters (d = 1, 3, 5 and 7 mm) on their central area. The investigation indicates that among the perforated WVGs, the P-RWVG at d = 1 mm yields the highest heat transfer and friction factor up to 6.78 and 84.32 times higher than the smooth duct but the best thermal performance of about 2.01 is found for the P-TWVG with d = 5 mm. To explore the flow and heat transfer pattern, a 3D numerical flow simulation is performed and validated with available measurements where both the numerical and measured results are in good agreement.
引用
收藏
页码:1101 / 1117
页数:17
相关论文
共 44 条