Detection of Minor Winding Deformation Fault in High Frequency Range for Power Transformer

被引:0
|
作者
Tang, W. H. [1 ]
Shintemirov, A. [1 ]
Wu, Q. H. [1 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
关键词
Transformer winding; distortion fault; frequency response analysis; MOVEMENT;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a simplified distributed parameter model for minor winding deformation fault analysis of power transformers on the basis of frequency response analysis (FRA). The FRA data of an experimental transformer is employed as a reference trace, which are compared with the simulations of the simplified distributed parameter model concerning minor winding deformation faults. In order to perform quantitative analysis when a deformation fault occurs, three statistical indicators are used to analyze the FRA simulation data. It is suggested in the results that minor winding deformation faults can be detected at the frequency range above 1 MHz.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Influence Factor on Sweep Frequency Impedance to Detect Winding Deformation within Power Transformer
    Wu, Jingfeng
    Mao, Chen
    Han, Yanhua
    Huang, Guoqiang
    Yang, Chuankai
    Yang, Fan
    Ren, Fuqiang
    2016 IEEE INTERNATIONAL POWER MODULATOR AND HIGH VOLTAGE CONFERENCE (IPMHVC), 2016, : 659 - 662
  • [22] An Experimental Study of the Sweep Frequency Impedance Method on the Winding Deformation of an Onsite Power Transformer
    Wang, Song
    Wang, Shuang
    Cui, Ying
    Long, Jie
    Ren, Fuqiang
    Ji, Shengchang
    Wang, Shuhong
    ENERGIES, 2020, 13 (14)
  • [23] Fault diagnostics of transformer winding in time and frequency domain
    Korenciak D.
    Gutten M.
    Diagnostyka, 2020, 21 (03): : 49 - 54
  • [24] High frequency model of transformer winding
    Shibuya, Y
    Fujita, S
    ELECTRICAL ENGINEERING IN JAPAN, 2004, 146 (03) : 8 - 16
  • [25] Using the Vibration Frequency Response Analysis Method to Detect the Winding Deformation of Power Transformer
    Wang, F. H.
    Jin, Z. J.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [26] Study of Transformer Winding Deformation by Frequency Response Analysis
    Yousof, M. F. M.
    Ekanayake, C.
    Saha, T. K.
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [27] Frequency Response Analysis to Investigate Deformation of Transformer Winding
    Yousof, M. Fairouz M.
    Ekanayake, Chandima
    Saha, Tapan K.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (04) : 2359 - 2367
  • [28] Method for Detecting System on Power Transformer Winding Deformation
    Ma Shaohua
    Ren He
    2009 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2009, : 991 - 995
  • [29] Research Situation Analysis of On-line Detection Technology for Power Transformer Winding Deformation
    Li, Zhenhua
    Jiang, Weihui
    Qiu, Li
    Li, Zhenxing
    Xu, Yanchun
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2020, 13 (06) : 831 - 840
  • [30] Research situation analysis of on-line detection technology for power transformer winding deformation
    Li, Zhenhua
    Jiang, Weihui
    Qiu, Li
    Li, Zhenxing
    Xu, Yanchun
    Li, Zhenhua (lizhenhua1993@163.com), 1600, Bentham Science Publishers (13): : 831 - 840