Localization and Evaluation of Sentinel Lymph Node in Breast Cancer From Computed Tomographic Lymphography

被引:7
作者
Tan, Hongna [1 ,2 ]
Yang, Benlong [2 ,3 ]
Wu, Jiong [2 ,3 ]
Wana, Shengping [1 ,2 ]
Gu, Yajia [1 ,2 ]
Li, Wentao [1 ,2 ]
Jiang, Zhaoxia [1 ,2 ]
Qian, Min [1 ,2 ]
Peng, Weijun [1 ,2 ]
机构
[1] Fudan Univ, Dept Radiol, Canc Hosp, Inst Canc, Shanghai 200032, Peoples R China
[2] Fudan Univ, Dept Breast Surg, Canc Hosp, Inst Canc, Shanghai 200032, Peoples R China
[3] Fudan Univ, Shanghai Med Coll, Dept Oncol, Shanghai 200032, Peoples R China
关键词
breast cancer; sentinel lymph node; computed tomography; lymphography; axillary lymph node status; BLUE-DYE; MAGNETIC-RESONANCE; CT LYMPHOGRAPHY; BIOPSY; INJECTION; ISOTOPE; TRIAL; EXPERIENCE; MORBIDITY; CARCINOMA;
D O I
10.1097/RCT.0b013e318213ccd9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: This study aimed to determine the accuracy of computed tomographic (CT) localization and CT-based diagnosis of sentinel lymph nodes (SLNs) metastasis. Methods: Thirty-four patients with confirmed breast cancer underwent 40-row CT scanning, and the first one or several lymph node(s) in the lymphatic drainage pathway was/were defined as the SLN(s). Dye and gamma probe-guided SLN biopsy was performed on all patients. To accurately localize the SLN, 19 patients (55.9%) underwent the percutaneous lymph node puncture procedure. The morphologic features of all the SLNs on CT scans were analyzed and compared with the SLN biopsy pathologic diagnosis. Results: Sentinel lymph nodes were successfully identified for all patients without any significant adverse effects. All localized SLNs corresponded well with SLNs identified on SLN biopsy, with an accuracy of 89.5%. Accuracy increased to 100% when the CT scan technique was combined with the blue dye method. The size criteria for metastatic diagnosis had a sensitivity of 85%, which increased to 94.7% when long-to-short-axis ratio and margin characteristics were also considered. Conclusions: The CT lymphography combined with the blue dye method accurately localized the SLNs. The CT-based diagnostic criteria improved the diagnostic accuracy of SLN metastases and were useful for evaluating the axillary status in early stage breast cancer patients.
引用
收藏
页码:367 / 374
页数:8
相关论文
共 50 条
  • [31] Sentinel nodes identified by computed tomography-lymphography accurately stage the axilla in patients with breast cancer
    Motomura, Kazuyoshi
    Sumino, Hiroshi
    Noguchi, Atsushi
    Horinouchi, Takashi
    Nakanishi, Katsuyuki
    BMC MEDICAL IMAGING, 2013, 13
  • [32] Strategies in case of metastatic sentinel lymph node in breast cancer
    Costaz, Helene
    Rouffiac, Magali
    Boulle, Delphine
    Arnould, Laurent
    Beltjens, Francoise
    Desmoulins, Isabelle
    Peignaux, Karine
    Ladoire, Sylvain
    Vincent, Laura
    Jankowski, Clementine
    Coutant, Charles
    BULLETIN DU CANCER, 2020, 107 (06) : 672 - 685
  • [33] Clinical significance of breast cancer micrometastasis in the sentinel lymph node
    Shimazu, Kenzo
    Noguchi, Shinzaburo
    SURGERY TODAY, 2016, 46 (02) : 155 - 160
  • [34] Predicting sentinel lymph node metastasis in breast cancer with lymphoscintigraphy
    Noguchi, Atsushi
    Onoguchi, Masahisa
    Ohnishi, Takeshi
    Hashizume, Terumi
    Kajita, Akiyoshi
    Funauchi, Masahiro
    Katsuda, Toshizo
    Motomura, Kazuyoshi
    ANNALS OF NUCLEAR MEDICINE, 2011, 25 (03) : 221 - 226
  • [35] Localization of sentinel lymph node in breast cancer. A prospective study
    Marrazzo, Antonio
    Palumbo, Vincenzo Davide
    Marrazzo, Emilia
    Taormina, Pietra
    Damiano, Giuseppe
    Buscemi, Salvatore
    Buscemi, Giuseppe
    Lo Monte, Attilio Ignazio
    INTERNATIONAL JOURNAL OF SURGERY, 2014, 12 : S162 - S164
  • [36] The clinical significance of sentinel lymph node micrometastasis in breast cancer
    Patani, Neill
    Mokbel, Kefah
    BREAST CANCER RESEARCH AND TREATMENT, 2009, 114 (03) : 393 - 402
  • [37] Imaging features of sentinel lymph node mapped by multidetector-row computed tomography lymphography in predicting axillary lymph node metastasis
    Ou, Xiaochan
    Zhu, Jianbin
    Qu, Yaoming
    Wang, Chengmei
    Wang, Baiye
    Xu, Xirui
    Wang, Yanyu
    Wen, Haitao
    Ma, Andong
    Liu, Xinzi
    Zou, Xia
    Wen, Zhibo
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [38] Prospective ultrasonographic prediction of sentinel lymph node metastasis by real-time virtual sonography constructed with three-dimensional computed tomography–lymphography in breast cancer patients
    Shigeru Yamamoto
    Noriko Maeda
    Michiko Tamesa
    Yukiko Nagashima
    Kiyoshi Yoshimura
    Masaaki Oka
    Breast Cancer, 2012, 19 : 77 - 82
  • [39] Sentinel lymph node detection using magnetic resonance lymphography with conventional gadolinium contrast agent in breast cancer: a preliminary clinical study
    Li, Chuanming
    Meng, Shan
    Yang, Xinhua
    Zhou, Daiquan
    Wang, Jian
    Hu, Jiani
    BMC CANCER, 2015, 15
  • [40] Predicting Factors of Nonsentinel Lymph Node Metastasis in Breast Cancer Patients with Sentinel Lymph Node Metastasis
    Park, Jae Young
    Park, Keun Myoung
    Park, Jeong Mi
    Lee, Kang Yeun
    Moon, Youn Hee
    Kim, Sei Joong
    Kim, Joon Mee
    Cho, Young Up
    Kim, Jang Yong
    Choe, Yun-Mee
    Choi, Sun Keun
    Heo, Yoon-Seok
    Lee, Keon-Young
    Ahn, Seung-Ik
    Hong, Kee Chun
    Shin, Seok-Hwan
    Kim, Kyung Rae
    JOURNAL OF THE KOREAN SURGICAL SOCIETY, 2010, 79 (01): : 20 - 26