Localization and Evaluation of Sentinel Lymph Node in Breast Cancer From Computed Tomographic Lymphography

被引:7
作者
Tan, Hongna [1 ,2 ]
Yang, Benlong [2 ,3 ]
Wu, Jiong [2 ,3 ]
Wana, Shengping [1 ,2 ]
Gu, Yajia [1 ,2 ]
Li, Wentao [1 ,2 ]
Jiang, Zhaoxia [1 ,2 ]
Qian, Min [1 ,2 ]
Peng, Weijun [1 ,2 ]
机构
[1] Fudan Univ, Dept Radiol, Canc Hosp, Inst Canc, Shanghai 200032, Peoples R China
[2] Fudan Univ, Dept Breast Surg, Canc Hosp, Inst Canc, Shanghai 200032, Peoples R China
[3] Fudan Univ, Shanghai Med Coll, Dept Oncol, Shanghai 200032, Peoples R China
关键词
breast cancer; sentinel lymph node; computed tomography; lymphography; axillary lymph node status; BLUE-DYE; MAGNETIC-RESONANCE; CT LYMPHOGRAPHY; BIOPSY; INJECTION; ISOTOPE; TRIAL; EXPERIENCE; MORBIDITY; CARCINOMA;
D O I
10.1097/RCT.0b013e318213ccd9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: This study aimed to determine the accuracy of computed tomographic (CT) localization and CT-based diagnosis of sentinel lymph nodes (SLNs) metastasis. Methods: Thirty-four patients with confirmed breast cancer underwent 40-row CT scanning, and the first one or several lymph node(s) in the lymphatic drainage pathway was/were defined as the SLN(s). Dye and gamma probe-guided SLN biopsy was performed on all patients. To accurately localize the SLN, 19 patients (55.9%) underwent the percutaneous lymph node puncture procedure. The morphologic features of all the SLNs on CT scans were analyzed and compared with the SLN biopsy pathologic diagnosis. Results: Sentinel lymph nodes were successfully identified for all patients without any significant adverse effects. All localized SLNs corresponded well with SLNs identified on SLN biopsy, with an accuracy of 89.5%. Accuracy increased to 100% when the CT scan technique was combined with the blue dye method. The size criteria for metastatic diagnosis had a sensitivity of 85%, which increased to 94.7% when long-to-short-axis ratio and margin characteristics were also considered. Conclusions: The CT lymphography combined with the blue dye method accurately localized the SLNs. The CT-based diagnostic criteria improved the diagnostic accuracy of SLN metastases and were useful for evaluating the axillary status in early stage breast cancer patients.
引用
收藏
页码:367 / 374
页数:8
相关论文
共 50 条
  • [11] Utility of single-photon emission tomography/computed tomography for sentinel lymph node localization in breast cancer patients
    Gizewska, Agnieszka
    Witkowska-Patena, Ewa
    Osiecki, Sebastian
    Mazurek, Andrzej
    Stembrowicz-Nowakowska, Zofia
    Dziuk, Miroslaw
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (06) : 493 - 499
  • [12] Evaluation of sentinel lymph node metastasis alone guided by three-dimensional computed tomographic lymphography in video-assisted breast surgery
    K. Yamashita
    K. Shimizu
    Surgical Endoscopy, 2009, 23 : 633 - 640
  • [13] Sentinel Lymph Node Detection in Breast Cancer Patients by Real-Time Virtual Sonography Constructed With Three-Dimensional Computed Tomography-Lymphography
    Yamamoto, Shigeru
    Maeda, Noriko
    Tamesa, Michiko
    Nagashima, Yukiko
    Suga, Kazuyoshi
    Oka, Masaaki
    BREAST JOURNAL, 2010, 16 (01) : 4 - 8
  • [14] Prospective ultrasonographic prediction of sentinel lymph node metastasis by real-time virtual sonography constructed with three-dimensional computed tomography-lymphography in breast cancer patients
    Yamamoto, Shigeru
    Maeda, Noriko
    Tamesa, Michiko
    Nagashima, Yukiko
    Yoshimura, Kiyoshi
    Oka, Masaaki
    BREAST CANCER, 2012, 19 (01) : 77 - 82
  • [15] Video-assisted breast surgery and sentinel lymph node biopsy guided by three-dimensional computed tomographic lymphography
    Yamashita, K.
    Shimizu, K.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2008, 22 (02): : 392 - 397
  • [16] Video-assisted breast surgery and sentinel lymph node biopsy guided by three-dimensional computed tomographic lymphography
    K. Yamashita
    K. Shimizu
    Surgical Endoscopy, 2008, 22 : 392 - 397
  • [17] Sentinel Lymph Node Positive Rate Predicts Non-Sentinel Lymph Node Metastasis in Breast Cancer
    Wang, Xuefei
    Zhang, Guochao
    Zuo, Zhichao
    Zhu, Qingli
    Wu, Shafei
    Zhou, Yidong
    Mao, Feng
    Lin, Yan
    Shen, Songjie
    Zhang, Xiaohui
    Qin, Xue
    Yan, Cunli
    Ma, Xiaoying
    Shi, Yue
    Sun, Qiang
    JOURNAL OF SURGICAL RESEARCH, 2022, 271 : 59 - 66
  • [18] Breast sentinel lymph node navigation with three-dimensional computed tomography–lymphography: a 12-year study
    Shigeru Yamamoto
    Kazuyoshi Suga
    Kazunari Maeda
    Noriko Maeda
    Kiyoshi Yoshimura
    Masaaki Oka
    Breast Cancer, 2016, 23 : 456 - 462
  • [19] Sentinel lymph node detection using computed tomography lymphography is accurate after neoadjuvant chemotherapy for breast cancer
    Ue, Hironobu
    Ogawa, Yasuhiro
    Kariya, Shinji
    Nakatani, Kimiko
    Tsuzuki, Kazuhiro
    Miyatake, Kana
    Maeda, Hironori
    Tanaka, Yosuke
    Sasaguri, Shiro
    ONCOLOGY REPORTS, 2007, 17 (06) : 1475 - 1480
  • [20] The development of an indirect computed tomography lymphography protocol for sentinel lymph node detection in head and neck cancer and comparison to other sentinel lymph node mapping techniques
    Randall, Elissa K.
    Jones, Matthew D.
    Kraft, Susan L.
    Worley, Deanna R.
    VETERINARY AND COMPARATIVE ONCOLOGY, 2020, 18 (04) : 634 - 644