Localization and Evaluation of Sentinel Lymph Node in Breast Cancer From Computed Tomographic Lymphography

被引:7
作者
Tan, Hongna [1 ,2 ]
Yang, Benlong [2 ,3 ]
Wu, Jiong [2 ,3 ]
Wana, Shengping [1 ,2 ]
Gu, Yajia [1 ,2 ]
Li, Wentao [1 ,2 ]
Jiang, Zhaoxia [1 ,2 ]
Qian, Min [1 ,2 ]
Peng, Weijun [1 ,2 ]
机构
[1] Fudan Univ, Dept Radiol, Canc Hosp, Inst Canc, Shanghai 200032, Peoples R China
[2] Fudan Univ, Dept Breast Surg, Canc Hosp, Inst Canc, Shanghai 200032, Peoples R China
[3] Fudan Univ, Shanghai Med Coll, Dept Oncol, Shanghai 200032, Peoples R China
关键词
breast cancer; sentinel lymph node; computed tomography; lymphography; axillary lymph node status; BLUE-DYE; MAGNETIC-RESONANCE; CT LYMPHOGRAPHY; BIOPSY; INJECTION; ISOTOPE; TRIAL; EXPERIENCE; MORBIDITY; CARCINOMA;
D O I
10.1097/RCT.0b013e318213ccd9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: This study aimed to determine the accuracy of computed tomographic (CT) localization and CT-based diagnosis of sentinel lymph nodes (SLNs) metastasis. Methods: Thirty-four patients with confirmed breast cancer underwent 40-row CT scanning, and the first one or several lymph node(s) in the lymphatic drainage pathway was/were defined as the SLN(s). Dye and gamma probe-guided SLN biopsy was performed on all patients. To accurately localize the SLN, 19 patients (55.9%) underwent the percutaneous lymph node puncture procedure. The morphologic features of all the SLNs on CT scans were analyzed and compared with the SLN biopsy pathologic diagnosis. Results: Sentinel lymph nodes were successfully identified for all patients without any significant adverse effects. All localized SLNs corresponded well with SLNs identified on SLN biopsy, with an accuracy of 89.5%. Accuracy increased to 100% when the CT scan technique was combined with the blue dye method. The size criteria for metastatic diagnosis had a sensitivity of 85%, which increased to 94.7% when long-to-short-axis ratio and margin characteristics were also considered. Conclusions: The CT lymphography combined with the blue dye method accurately localized the SLNs. The CT-based diagnostic criteria improved the diagnostic accuracy of SLN metastases and were useful for evaluating the axillary status in early stage breast cancer patients.
引用
收藏
页码:367 / 374
页数:8
相关论文
共 50 条
  • [1] Application of preoperative computed tomographic lymphography for precise sentinel lymph node biopsy in breast cancer patients
    Wen, Shishuai
    Liang, Yiran
    Kong, Xiaoli
    Liu, Baofeng
    Ma, Tingting
    Zhou, Yeqing
    Jiang, Liyu
    Li, Xiaoyan
    Yang, Qifeng
    BMC SURGERY, 2021, 21 (01)
  • [2] Breast sentinel lymph node navigation with three-dimensional interstitial multidetector-row computed tomographic lymphography
    Suga, K
    Yamamoto, S
    Tangoku, A
    Oka, M
    Kawakami, Y
    Matsunaga, N
    INVESTIGATIVE RADIOLOGY, 2005, 40 (06) : 336 - 342
  • [3] Evaluation of sentinel lymph node metastasis alone guided by three-dimensional computed tomographic lymphography in video-assisted breast surgery
    Yamashita, K.
    Shimizu, K.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2009, 23 (03): : 633 - 640
  • [4] Computed tomography lymphography with intrapulmonary injection of lopamidol for sentinel lymph node localization
    Suga, K
    Yuan, Y
    Ueda, K
    Kaneda, Y
    Kawakami, Y
    Zaki, M
    Matsunaga, N
    INVESTIGATIVE RADIOLOGY, 2004, 39 (06) : 313 - 324
  • [5] Computed tomographic lymphography for sentinel lymph node biopsy in male breast cancer: report of two cases
    Hashimoto, Naoki
    Kudo, Yurie
    Kurushima, Michihiro
    Suzuki, Yamato
    Yachi, Takafumi
    Tokura, Tomohisa
    Umehara, Yutaka
    Nishikawa, Shinsuke
    Takahashi, Kenichi
    Morita, Takayuki
    Narita, Fumiko
    SPRINGERPLUS, 2013, 2 : 1 - 6
  • [6] Sentinel lymph node biopsy using computed tomographic lymphography in patients with early tongue cancer
    Honda, Kohei
    Ishiyama, Koich
    Suzuki, Shinsuke
    Oumi, Eigo
    Sato, Teruyuki
    Kawasaki, Yohei
    Saito, Hidekazu
    Ishikawa, Kazuo
    ACTA OTO-LARYNGOLOGICA, 2015, 135 (05) : 507 - 512
  • [7] Breast sentinel lymph node navigation with three-dimensional computed tomography-lymphography: a 12-year study
    Yamamoto, Shigeru
    Suga, Kazuyoshi
    Maeda, Kazunari
    Maeda, Noriko
    Yoshimura, Kiyoshi
    Oka, Masaaki
    BREAST CANCER, 2016, 23 (03) : 456 - 462
  • [8] ASSESSMENT OF SENTINEL LYMPH NODE METASTASIS IN CANINE MAMMARY GLAND TUMORS USING COMPUTED TOMOGRAPHIC INDIRECT LYMPHOGRAPHY
    Soultani, Christina
    Patsikas, Michail N.
    Karayannopoulou, Maria
    Jakovljevic, Samuel
    Chryssogonidis, Ioannis
    Papazoglou, Lysimachos
    Papaioannou, Nikolaos
    Papadopoulou, Paraskevi
    Pavlidou, Kyriaki
    Ilia, Georgia M.
    Kaitzis, Dimitrios G.
    Ilia, Tatiana M.
    VETERINARY RADIOLOGY & ULTRASOUND, 2017, 58 (02) : 186 - 196
  • [9] Computed tomographic lymphography predicts the difficulty of sentinel lymph node biopsy with dye
    Kazunori Yokohata
    Masami Hattori
    Takaaki Fujimoto
    Nobuhito Chikazawa
    Ryo Maeyama
    Naoki Yamanaka
    Hideo Kuroki
    Nobuhiko Sasaki
    Nobuhisa Kameoka
    Naoyuki Matoba
    Breast Cancer, 2014, 21 : 198 - 201
  • [10] Computed tomographic lymphography predicts the difficulty of sentinel lymph node biopsy with dye
    Yokohata, Kazunori
    Hattori, Masami
    Fujimoto, Takaaki
    Chikazawa, Nobuhito
    Maeyama, Ryo
    Yamanaka, Naoki
    Kuroki, Hideo
    Sasaki, Nobuhiko
    Kameoka, Nobuhisa
    Matoba, Naoyuki
    BREAST CANCER, 2014, 21 (02) : 198 - 201