The hand-hold polarization-sensitive spectral domain optical coherence and its applications

被引:0
作者
Liu, Hao [1 ]
Gao, Wanrong [1 ]
机构
[1] Nanjing Univ Sci & Technol, Dept Opt Engn, 200 Xiao Ling Wei, Nanjing 210094, Jiangsu, Peoples R China
来源
POLARIZATION SCIENCE AND REMOTE SENSING VIII | 2017年 / 10407卷
关键词
optical coherence tomography; handhold; polarization; applications; TOMOGRAPHY; CAMERA;
D O I
10.1117/12.2272530
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
The polarization-sensitive spectral domain optical coherence tomography (PSOCT) has the advantages of being able to measure the polarization properties of samples, such as phase-retardation, diattenuation, depolarization, and optical axis orientation, providing a contrast to identify the diseased area and normal area in tissues in PSOCT images. Conventionally, the sample arm of PSOCT is fixed on the stage where biomedical tissues or models is placed, and the OCT images is acquired by scanning with a galvanometer-based mirror. To be applied in the practical diagnosis, a promising way is to design a hand-held device. To this end, it is required that probe is assembled with a small volume to allow for comprehensively imaging large tissues areas at a microscopic scale, and is available to move on different samples to be acquired quickly with negligible motion artifacts. Meanwhile, the probe should be manufactured wih well stability to avoid system jitter error while it is used to detect the biological tissues in vivo. In this work, a design of a hand-hold fiber-based PSOCT is described. The device is of the size of 10 cm (length) x 8 cm (width) x 6 cm (height). Both the axial resolution and the imaging depth of the system are measured and were approximately 7 mu m and 2.5 mm in air, respectively, which are in good agreement with the theoretical predictions. The A-scan rate of the system is 70 kHz. The structure is compact and all the components are fixed on the shell to reduce the motion artifact, resulting in a great stability on measuring the tissues in vivo. The cross sectional images of ex vivo chicken breast, ex vivo pork cartilage and in vivo forearm skin of human wolunteer are presented to demonstrate the capability of the system.
引用
收藏
页数:6
相关论文
共 14 条
  • [1] Polarization-sensitive optical coherence tomography based on polarization-maintaining fibers and frequency multiplexing
    Al-Qaisi, Muhammad K.
    Akkin, Taner
    [J]. OPTICS EXPRESS, 2008, 16 (17) : 13032 - 13041
  • [2] Polarization-sensitive spectral-domain optical coherence tomography using a single line scan camera
    Cense, Barry
    Mujat, Mircea
    Chen, Teresa C.
    Park, B. Hyle
    de Boer, Johannes F.
    [J]. OPTICS EXPRESS, 2007, 15 (05): : 2421 - 2431
  • [3] Chen Yueli, 2005, Appl Opt, V44, P2041, DOI 10.1364/AO.44.002041
  • [4] Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
    de Boer, JF
    Cense, B
    Park, BH
    Pierce, MC
    Tearney, GJ
    Bouma, BE
    [J]. OPTICS LETTERS, 2003, 28 (21) : 2067 - 2069
  • [5] Determination of the depth-resolved Stokes parameters of light backscattered from turbid media by use of polarization-sensitive optical coherence tomography
    de Boer, JF
    Milner, TE
    Nelson, JS
    [J]. OPTICS LETTERS, 1999, 24 (05) : 300 - 302
  • [6] Quantitative single-mode fiber based PS-OCT with single input polarization state using Mueller matrix
    Ding, Zhenyang
    Liang, Chia-Pin
    Tang, Qinggong
    Chen, Yu
    [J]. BIOMEDICAL OPTICS EXPRESS, 2015, 6 (05): : 1828 - 1843
  • [7] Spectral domain polarization sensitive optical coherence tomography achieved by single camera detection
    Fan, Chuanmao
    Wang, Yi
    Wang, Ruikang K.
    [J]. OPTICS EXPRESS, 2007, 15 (13) : 7950 - 7961
  • [8] Imaging caries lesions and lesion progression with polarization sensitive optical coherence tomography
    Fried, D
    Xie, J
    Shafi, S
    Featherstone, JDB
    Breunig, TM
    Le, C
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (04) : 618 - 627
  • [9] High speed spectral domain polarization sensitive optical coherence tomography of the human retina
    Götzinger, E
    Pircher, M
    Hitzenberger, CK
    [J]. OPTICS EXPRESS, 2005, 13 (25): : 10217 - 10229
  • [10] Hao L., 2016, CHINESE J LASERS, P124