Improvements in micro-CT method for characterizing X-ray monocapillary optics

被引:4
作者
Wang, Zhao [1 ,2 ,3 ]
Pan, Kai [2 ,3 ]
Du, Zelin [2 ,3 ]
Zhang, Shuang [2 ,3 ]
Liu, Zhiguo [2 ,3 ,4 ]
机构
[1] China Acad Engn Phys, Inst Appl Elect, Mianyang 621900, Sichuan, Peoples R China
[2] Beijing Normal Univ, Coll Nucl Sci & Technol, Beijing 100875, Peoples R China
[3] Beijing Normal Univ, Dept Phys, Appl Opt Beijing Area Major Lab, Beijing 100875, Peoples R China
[4] Beijing Radiat Ctr, Beijing 100875, Peoples R China
关键词
X-ray monocapillary optics; Micro-CT; Sparse sampling; GPU acceleration; Geometric calibration; CONE-BEAM CT; GEOMETRIC CALIBRATION; IMAGE-RECONSTRUCTION; INNER DIAMETER; CONDENSER;
D O I
10.1016/j.optcom.2021.127474
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Accurate characterization of the inner surface of X-ray monocapillary optics (XMCO) is of great significance in X-ray optics research. Compared with other characterization methods, the micro computed tomography (micro-CT) method has its unique advantages but also has some disadvantages, such as a long scanning time, long image reconstruction time, and inconvenient scanning process. In this paper, sparse sampling was proposed to shorten the scanning time, GPU acceleration technology was used to improve the speed of image reconstruction, and a simple geometric calibration algorithm was proposed to avoid the calibration phantom and simplify the scanning process. These methodologies will popularize the use of the micro-CT method in XMCO characterization.
引用
收藏
页数:9
相关论文
共 50 条
[41]   Utility of a prototype liposomal contrast agent for x-ray imaging of breast cancer: a proof of concept using micro-CT in small animals [J].
Badea, C. T. ;
Samei, E. ;
Ghaghada, K. ;
Saunders, R. ;
Yuan, H. ;
Qi, Y. ;
Hedlund, L. W. ;
Mukundan, S. .
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
[42]   Image reconstruction using em method in X-ray CT [J].
Dong, Bao-Yu .
2007 INTERNATIONAL CONFERENCE ON WAVELET ANALYSIS AND PATTERN RECOGNITION, VOLS 1-4, PROCEEDINGS, 2007, :130-134
[43]   High-quality quasi-parallel X-ray beam obtained by a parabolic monocapillary X-ray lens with a square beam stop [J].
Zhou, Peng ;
Cui, Jingduo ;
Du, Zelin ;
Zhang, Tao ;
Liu, Zhiguo .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (02) :261-273
[44]   Comparison of high-resolution X-ray and micro-CT for experimental evaluation of intracranial stent prototypes: quality evaluation beyond CE mark [J].
Keuler, Andreas ;
Taschner, Christian ;
Brockmann, Marc Alexander ;
Boll, Hanne ;
Foerster, Katharina ;
Lutz, Lisa ;
Herrmann-Frank, Annegret ;
Lelgemann, Monika ;
Schumacher, Martin .
NEURORADIOLOGY, 2014, 56 (04) :315-323
[45]   Comparison of high-resolution X-ray and micro-CT for experimental evaluation of intracranial stent prototypes: quality evaluation beyond CE mark [J].
Andreas Keuler ;
Christian Taschner ;
Marc Alexander Brockmann ;
Hanne Boll ;
Katharina Förster ;
Lisa Lutz ;
Annegret Herrmann-Frank ;
Monika Lelgemann ;
Martin Schumacher .
Neuroradiology, 2014, 56 :315-323
[46]   X-ray CT geometrical calibration via locally linear embedding [J].
Chen, Mianyi ;
Xi, Yan ;
Cong, Wenxiang ;
Liu, Baodong ;
Wei, Biao ;
Wang, Ge .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (02) :241-256
[47]   Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray [J].
Cao, Guohua ;
Burk, Laurel M. ;
Lee, Yueh Z. ;
Calderon-Colon, Xiomara ;
Sultana, Shabana ;
Lu, Jianping ;
Zhou, Otto .
MEDICAL PHYSICS, 2010, 37 (10) :5306-5312
[48]   Ethanol fixation method for heart and lung imaging in micro-CT [J].
Patzelt, Matej ;
Mrzilkova, Jana ;
Dudak, Jan ;
Krejci, Frantisek ;
Zemlicka, Jan ;
Karch, Jakub ;
Musil, Vladimir ;
Rosina, Jozef ;
Sykora, Viktor ;
Horehledova, Barbora ;
Zach, Petr .
JAPANESE JOURNAL OF RADIOLOGY, 2019, 37 (06) :500-510
[49]   Adaptive region of interest method for analytical micro-CT reconstruction [J].
Yang, Wanneng ;
Xu, Xiaochun ;
Bi, Kun ;
Zeng, Shaoqun ;
Liu, Qian ;
Chen, Shangbin .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (01) :23-33
[50]   Ethanol fixation method for heart and lung imaging in micro-CT [J].
Matej Patzelt ;
Jana Mrzilkova ;
Jan Dudak ;
Frantisek Krejci ;
Jan Zemlicka ;
Jakub Karch ;
Vladimir Musil ;
Jozef Rosina ;
Viktor Sykora ;
Barbora Horehledova ;
Petr Zach .
Japanese Journal of Radiology, 2019, 37 :500-510