Investigation of silica-based TL media for diagnostic x-ray dosimetry

被引:14
作者
Alyahyawi, Amjad [1 ,4 ]
Rozaila, Z. Siti [2 ]
Shafiqah, A. S. Siti [3 ]
Sabtu, Siti Norbaini [2 ]
Alsubaie, A. [1 ,5 ]
Alanazi, A. [1 ,6 ]
Daar, Eman [1 ,7 ]
Sani, S. F. Abdul [2 ]
Bradley, D. A. [1 ,8 ]
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
[2] Univ Malaya, Dept Phys, Kuala Lumpur 50603, Malaysia
[3] Int Islamic Univ Malaysia, Dept Phys, Kuantan 25200, Malaysia
[4] Univ Hail, Dept Diagnost Radiol, Hail, Saudi Arabia
[5] Taif Univ, Al Khurmah Branch, Dept Phys, At Taif 888, Saudi Arabia
[6] Prince Mohammed Med City, Canc Ctr, 2254 Sakaka, Aljouf 42421, Saudi Arabia
[7] Univ Jordan, Fac Sci, Dept Phys, Amman 11942, Jordan
[8] Sunway Univ, Inst Hlth Care Dev, Jalan Univ, Pj 46150, Malaysia
关键词
Ge-doped silica; Thermoluminesence photonic crystal fibre; TLD; Chest imaging; Dosimetry; DOPED OPTICAL-FIBERS; THERMOLUMINESCENCE RESPONSE; PHOTON IRRADIATION; GE;
D O I
10.1016/j.radphyschem.2016.12.018
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We focus on the development of Ge-doped silica thermoluminescent dosimeters with sensitivity superior to that of the LiF (Mg,Ti) phosphors popularly used in x-ray diagnostic imaging dosimetry, the latter typically being referred to through use of the product identifier TLD-100. Of interest are Ge-doped silica telecommunication fibres (SMF) and tailor-made doped photonic crystal fibres (PCFc), the latter Ge-doped or also co-doped with boron. The PCFs are formed of capillaries that at high temperatures and under vacuum are made to collapse inwards (PCFc), the internal walls fusing and generating strain-related defects. To-date, the fabricated SMF, PCFc-Ge and PCFc-Ge-B have been observed to provide TL yields which weight-for-weight are some 2, 10 and 15x that of TLD-100. In present study we test the linearity of TL yield for x-ray doses from 0.1- to 10 mGy, use being made of an x-ray tube operated at 80 kVp, an operating potential typically selected in chest radiography. For a dose of 10 mGy, a study of energy dependence has been conducted using x-ray tube potentials of 80 kVp 100 kVp, and 120 kVp, with inherent filtration 0.9 mm Al measured at 75 kVp, and total filtration of 2.8 mm Al at 80 kVp.
引用
收藏
页码:78 / 82
页数:5
相关论文
共 27 条
[1]   Dosimetric Characteristics of a LKB: Cu,Mg Solid Thermoluminescence Detector [J].
Alajerami, Yasser Saleh Mustafa ;
Hashim, Suhairul ;
Ramli, Ahmad Termizi ;
Saleh, Muneer Aziz ;
Kadir, Ahmad Bazlie Bin Abdul ;
Saripan, Mohd. Iqbal .
CHINESE PHYSICS LETTERS, 2013, 30 (01)
[2]   Assessment of Ge-doped optical fibre as a TL-mode detector [J].
Benabdesselam, M. ;
Mady, F. ;
Girard, S. .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 2013, 360 :9-12
[3]   Enhancing the radiation dose detection sensitivity of optical fibres [J].
Bradley, D. A. ;
Mandiraji, G. Amouzad ;
Ghomeishi, M. ;
Dermosesian, E. ;
Adikan, F. R. M. ;
Rashid, H. A. A. ;
Maah, M. J. .
APPLIED RADIATION AND ISOTOPES, 2015, 100 :43-49
[4]   Review of doped silica glass optical fibre: Their TL properties and potential applications in radiation therapy dosimetry [J].
Bradley, D. A. ;
Hugtenburg, R. P. ;
Nisbet, A. ;
Rahman, Ahmad Taufek Abdul ;
Issa, Fatma ;
Noor, Noramaliza Mohd ;
Alalawi, Amani .
APPLIED RADIATION AND ISOTOPES, 2012, 71 :2-11
[5]   Improving thermoluminescence response through the fabrication of novel microstructured fibers [J].
Dermosesian, E. ;
Mahdiraji, G. Amouzad ;
Adikan, F. R. Mahamd ;
Bradley, D. A. .
RADIATION PHYSICS AND CHEMISTRY, 2015, 116 :135-137
[6]   Characteristics of radiation detectors for diagnostic radiology [J].
DeWerd, LA ;
Wagner, LK .
APPLIED RADIATION AND ISOTOPES, 1999, 50 (01) :125-136
[7]   The low energy X-ray response of the LiF:Mg:Cu:P thermoluminescent dosemeter:: a comparison with LiF:Mg:Ti [J].
Edwards, CR ;
Mountford, PJ ;
Green, S ;
Palethorpe, JE ;
Moloney, AJ .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (930) :543-547
[8]   Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits [J].
Fadzil, M. S. Ahmad ;
Ramli, N. N. H. ;
Jusoh, M. A. ;
Kadni, T. ;
Bradley, D. A. ;
Ung, N. M. ;
Suhairul, H. ;
Noor, N. Mohd .
9TH NATIONAL SEMINAR ON MEDICAL PHYSICS (NSMP2014), 2014, 546
[9]   Patient dosimetry measurement methods [J].
Faulkner, K ;
Broadhead, DA ;
Harrison, RM .
APPLIED RADIATION AND ISOTOPES, 1999, 50 (01) :113-123
[10]   Thermoluminescence studies of manganese doped calcium tetraborate (CaB4O7:Mn) nanocrystal synthesized by co-precipitation method [J].
Haghiri, Maryam Erfani ;
Saion, Elias ;
Abdullah, Wan Saffiey Wan ;
Soltani, Nayereh ;
Hashim, Mansor ;
Navasery, Manizheh ;
Shafaei, Mohammad Ali .
RADIATION PHYSICS AND CHEMISTRY, 2013, 90 :1-5