Effect of SSSC-based SSR controller on the performance of distance relay and adaptive approach using synchronized measurement

被引:10
作者
Dhenuvakonda, Koteswara Raju [1 ]
Singh, Arvind R. [2 ]
Thakre, Mohan P. [3 ]
Umre, Bhimrao S. [4 ]
Kumar, Abhishek [5 ]
Bansal, Ramesh C. [2 ]
机构
[1] Sreenidhi Inst Sci & Technol SNIST, Elect & Elect Engn Dept, Hyderabad, India
[2] Univ Pretoria, Dept Elect Elect & Comp Engn, Pretoria, South Africa
[3] KK Wagh Inst Engn Educ & Res, Elect Engn Dept, Nasik, India
[4] VNIT, Dept Elect Engn, Nagpur, Maharashtra, India
[5] Zhejiang Univ, Coll Elect Engn, Hangzhou, Zhejiang, Peoples R China
关键词
adaptive; distance relay; phasor measurement unit (PMU); SSR; SSSC; voltage source converter (VSC); TRANSMISSION-LINES; SUBSYNCHRONOUS RESONANCE; COMPENSATOR; PROTECTION; ALGORITHM; SHUNT;
D O I
10.1002/etep.2620
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The use of series compensation in a transmission line with capacitors may result in new problems like torsional oscillations in shaft sections of turbine-generator due to subsynchronous resonance (SSR) when system frequency matches with any one of torsional mode frequency of shaft system during fault or disturbances occur in the transmission line. The subsynchronous current due to SSR during fault also affects the reach of a distance protection system. The diminution of SSR is enhanced by series voltage injection into the power transmission line with static synchronous series compensator (SSSC) from the knowledge of subsynchronous components, extracted from the system. The use of SSSC in transmission line reduces the subsynchronous oscillations, but it adversely affects the distance protection system which leads to an imprecise assessment of fault location, ie, over or under-reach. This paper investigates the SSR mitigation in the presence of SSSC and its effect on distance protection scheme. A new approach is proposed for mitigating the problems associated with distance protection by using the synchrophasor measurement. The entire study of simulation is investigated by using a 48-pulse SSSC carried out with Bergeron model of transmission line in PSCAD. The simulation results represent that the suggested adaptive scheme is truthful, reliable, and secure with a change in compensation level of SSSC.
引用
收藏
页数:18
相关论文
共 34 条
[1]  
Albasri F. A., 2007, POW ENG SOC GEN M, P1
[2]  
Anderson P.M., 1998, Power System Protection
[3]  
Anderson P.M., 1989, Subsynchronous Resonance in Power Systems
[4]  
[Anonymous], 1985, IEEE T POWER AP SYST, V104, P1326
[5]  
[Anonymous], 2009, COMPUTER RELAYING PO
[6]   Accurate fault location algorithm for double-circuit series compensated lines using a limited number of two-end synchronized measurements [J].
Apostolopoulos, C. A. ;
Korres, G. N. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) :495-507
[7]   Single-phase VSC based SSSC for subsynchronous resonance damping [J].
Bongiorno, Massimo ;
Svensson, Jan ;
Angquist, Lennart .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (03) :1544-1552
[8]   On control of static synchronous series compensator for SSR mitigation [J].
Bongiorno, Massimo ;
Svensson, Jan ;
Angquist, Lennart .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (02) :735-743
[9]   Online estimation of subsynchronous voltage components in power systems [J].
Bongiorno, Massimo ;
Svensson, Jan ;
Angquist, Lennart .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (01) :410-418
[10]   THE EFFECT OF SUBSYNCHRONOUS CURRENT ON A STATIC MHO TYPE DISTANCE RELAY [J].
CHENG, TC ;
NING, TS .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (11) :4562-4570