Keratoconus Detection Based on a New Corneal Volumetric Analysis

被引:23
|
作者
Cavas-Martinez, Francisco [1 ]
Bataille, Laurent [1 ,2 ,4 ]
Fernandez-Pacheco, Daniel G. [1 ]
Canavate, Francisco J. F. [1 ]
Alio, Jorge L. [3 ,4 ,5 ]
机构
[1] Tech Univ Cartagena, Dept Graph Express, Cartagena, Spain
[2] Vissum Corp Alicante, Res & Dev Dept, Alicante, Spain
[3] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[4] Vissum Corp Alicante, Keratoconus Unit, Alicante, Spain
[5] Vissum Corp Alicante, Dept Refract Surg, Alicante, Spain
来源
SCIENTIFIC REPORTS | 2017年 / 7卷
关键词
PACHYMETRIC PARAMETERS; SCHEIMPFLUG TOMOGRAPHY; THICKNESS; ANTERIOR; ABERRATIONS; TOPOGRAPHY; INDEXES;
D O I
10.1038/s41598-017-16145-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
There are numerous tomographic indices for the detection of keratoconus risk. When the indexes based on corneal volume are analyzed, two problems are presented: on the one hand, they are not very sensitive to the detection of incipient cases of keratoconus because they are not locally defined in the primary developmental region of the structural abnormalities; and on the other hand, they do not register the geometric decompensation driven by the asymmetry present during the disease progression. This work performed a morphogeometric modeling of the cornea by the aid of CAD tools and using raw topographic data (Sirius system, CSO, Firenze). For this method, four singular points present on the corneal surfaces were located and the following parameters based on corneal volume were calculated: VOLmct, defined by the points of minimal thickness; VOLaap, defined by the anterior corneal apex, and VOLpap, defined by the posterior corneal apex. The results demonstrate that a further reduction of corneal volume in keratoconus happens and significantly progresses along the disease severity level. The combination of optical and volumetric data, that collect the sensitivity of the asymmetry generated by the disease, allows an accurate detection of incipient cases and follow up of the disease progression.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A new approach to keratoconus detection based on corneal morphogeometric analysis
    Cavas-Martinez, Francisco
    Bataille, Laurent
    Fernandez-Pacheco, Daniel G.
    Canavate, Francisco J. F.
    Alio, Jorge L.
    PLOS ONE, 2017, 12 (09):
  • [2] Corneal Asymmetry Analysis by Pentacam Scheimpflug Tomography for Keratoconus Diagnosis
    Galletti, Jonatan D.
    Ruisenor Vazquez, Pablo R.
    Minguez, Natalia
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfoertner, Tomas
    Galletti, Jeremias G.
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (02) : 116 - +
  • [3] Subclinical keratoconus detection with three-dimensional (3-D) morphogeometric and volumetric analysis
    Toprak, Ibrahim
    Cavas, Francisco
    Velazquez, Jose S.
    Alio del Barrio, Jorge L.
    Alio, Jorge L.
    ACTA OPHTHALMOLOGICA, 2020, 98 (08) : E933 - E942
  • [4] Evaluation of corneal topography and tomography in fellow eyes of unilateral keratoconus patients for early detection of subclinical keratoconus
    Thulasidas, Mithun
    Teotia, Prateek
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (11) : 2415 - 2420
  • [5] Detection of the early keratoconus based on corneal biomechanical properties in the refractive surgery candidates
    Pniakowska, Zofia
    Jurowski, Piotr
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (02) : 109 - 113
  • [6] Detection of keratoconus using wavefront analysis
    Mesplie, N.
    Leoni-Mesplie, S.
    Gallois, A.
    Colin, J.
    Touboul, D.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2011, 34 (08): : 547 - 556
  • [7] SmartKC: Smartphone-based Corneal Topographer for Keratoconus Detection
    Gairola, Siddhartha
    Bohra, Murtuza
    Shaheer, Nadeem
    Jayaprakash, Navya
    Joshi, Pallavi
    Balasubramaniam, Anand
    Murali, Kaushik
    Kwatra, Nipun
    Jain, Mohit
    PROCEEDINGS OF THE ACM ON INTERACTIVE MOBILE WEARABLE AND UBIQUITOUS TECHNOLOGIES-IMWUT, 2021, 5 (04):
  • [8] Keratoconus detection by corneal asymmetry analysis with Pentacam Scheimpflug tomography
    David Galletti, Jonatan
    Ruisenor Vazquez, Pablo Raul
    Ximena Minguez, Natalia
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfortner, Tomas
    Gaston Galletti, Jeremias
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [9] Robust keratoconus detection with Bayesian network classifier for Placido- based corneal indices
    Castro-Luna, Gracia M.
    Martinez-Finkelshtein, Andrei
    Ramos-Lopez, Dario
    CONTACT LENS & ANTERIOR EYE, 2020, 43 (04) : 366 - 372
  • [10] Vector Analysis of Evolutive Corneal Astigmatic Changes in Keratoconus
    Pinero, David P.
    Alio, Jorge L.
    Tomas, Javier
    Maldonado, Miguel J.
    Teus, Miguel A.
    Barraquer, Rafael I.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) : 4054 - 4062