The Effect of Corneal Refractive Power Area Changes on Myopia Progression during Orthokeratology

被引:10
|
作者
Chen, Minfeng [1 ]
Liu, Xinting [1 ]
Xie, Zhu [1 ]
Wang, Pengqi [1 ]
Zheng, Miaoran [1 ]
Mao, Xinjie [1 ]
机构
[1] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou 325000, Zhejiang, Peoples R China
关键词
AXIAL LENGTH ELONGATION; WAVE-FRONT ABERRATIONS; OVERNIGHT ORTHOKERATOLOGY; ABLATION CENTRATION; CONTACT-LENSES; DECENTRATION; SAFETY;
D O I
10.1155/2022/5530162
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To investigate the effect of corneal refractive power area changes on myopia progression during orthokeratology. Methods. One hundred and sixteen children who met the inclusion criteria and insisted on wearing orthokeratology lenses for two years were retrospectively assessed. Seventy-two children with the orthokeratology lens decentration distance more than 0.5 mm but less than 1.5 mm were in the decentered group, and forty-four children with the orthokeratology lens decentration distance less than 0.5 mm were in the centric group. The orthokeratology decentration via tangential difference topography was analyzed. This study calculated the different power areas in the central 4 mm pupillary area by axial-difference corneal topography, compared the differences of the different power areas between these two groups, and evaluated the relationships between corneal positive-power area, orthokeratology decentration, and AL changes. Results. The axial length changes of the centric group presented a statistical difference with the decentered group (0.52 +/- 0.37 mm vs. 0.38 +/- 0.26 mm; t = 2.403, p=0.018). For all children, both the AL changes (0.43 +/- 0.31 mm) and decentration distance (0.64 +/- 0.33 mm) showed a significant correlation with the positive-power area (r = -0.366, p < 0.001 and r = 0.624, p < 0.001); AL changes also presented a statistical correlation with decentration distance (r = -0.343, p < 0.001), baseline age (r = -0.329, p < 0.001), and baseline spherical equivalent refractive power (r = 0.335, p < 0.001). In the centric group and decentered group, the AL changes (centric group: r = -0.319, p=0.035; decentered group: r = -0.332, p=0.04) and decentration distance (centric group: r = 0.462, p=0.002; decentered group: r = 0.524, p < 0.001) had a significant correlation with the positive-power area yet. In the multiple regression analysis, AL changes were increased with less baseline age (beta, 0.015; p < 0.001), positive-power area (beta, 0.021; p=0.002), and larger SER (beta, 0.025; p=0.018). Conclusions. The corneal positive-power area had a positive impact on affirming AL changes during orthokeratology. This area might be formed by lens decentration to provide an additional myopia-defocusing influence on the retina to achieve better myopia control.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Changes in corneal subbasal nerve morphology and sensitivity during orthokeratology: Recovery of change
    Lum, Edward
    Golebiowski, Blanka
    Swarbrick, Helen A.
    OCULAR SURFACE, 2017, 15 (02): : 236 - 241
  • [42] Changes in Corneal Subbasal Nerve Morphology and Sensitivity During Orthokeratology: Onset of Change
    Lum, Edward
    Golebiowski, Blanka
    Swarbrick, Helen A.
    OCULAR SURFACE, 2017, 15 (02): : 227 - 235
  • [43] Changes in peripheral refraction during myopia progression in children
    Lin, Zhenghua
    Xi, Xiaoyun
    Wen, Longbo
    Luo, Zhiwei
    Lan, Weizhong
    Yang, Zhikuan
    Artal, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [44] Comments on: Refractive changes during off-the-axis retinoscopy in myopia
    Sutar, Samir
    Agarwal, Pradeep
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (10) : 3738 - 3739
  • [45] Corneal changes after laser refractive surgery for myopia: Comparison of Orbscan II and Pentacam findings
    Hashemi, Hassan
    Mehravaran, Shiva
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05): : 841 - 847
  • [46] The Relationship between Progression in Axial Length/Corneal Radius of Curvature Ratio and Spherical Equivalent Refractive Error in Myopia
    Jong, Monica
    Sankaridurg, Padmaja
    Naduvilath, Thomas John
    Li, Wayne
    He, Mingguang
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (10) : 921 - 929
  • [47] CHANGES IN CORNEAL REFRACTIVE POWER AFTER INTRAOCULAR-LENS IMPLANTATION
    PAROUSSIS, P
    GNAD, HD
    SKORPIK, C
    MARTINEZ, RM
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1985, 187 (05) : 430 - 431
  • [48] Corneal Reshaping Influences Myopic Prescription Stability (CRIMPS): An Analysis of the Effect of Orthokeratology on Childhood Myopic Refractive Stability
    Downie, Laura E.
    Lowe, Russell
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (04): : 303 - 310
  • [49] Effect of Pterygium Surgery on Refractive Spherocylinder Power and Corneal Topography
    Wu, Pei-Lun
    Kuo, Chien-Neng
    Hsu, Han-Lin
    Lai, Chien-Hsiung
    OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (01) : 32 - 37
  • [50] Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia
    Liu, Yongji
    Wang, Yan
    Wang, Zhaoqi
    Zuo, Tong
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2012, 32 (04) : 355 - 361