Electromyographic endotracheal tube placement during thyroid surgery in neuromonitoring of recurrent laryngeal nerve

被引:53
|
作者
Tsai, Cheng-Jing [1 ]
Tseng, Kuang-Yi [1 ]
Wang, Fu-Yuan [1 ]
Lu, I-Cheng [1 ,2 ]
Wang, Hsun-Mo [3 ]
Wu, Che-Wei [4 ,5 ]
Chiang, Hui-Ching [6 ]
Chiang, Feng-Yu [7 ,8 ]
机构
[1] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Anesthesiol, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Coll Med, Fac Med, Dept Anesthesiol, Kaohsiung, Taiwan
[3] Kaohsiung Municipal Tatung Hosp, Dept Otolaryngol, Kaohsiung, Taiwan
[4] Kaohsiung Med Univ, Grad Inst Clin Med, Kaohsiung, Taiwan
[5] Kaohsiung Municipal Hsiaokang Hosp, Dept Otolaryngol, Kaohsiung, Taiwan
[6] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Nursing, Kaohsiung, Taiwan
[7] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Otolaryngol, Kaohsiung, Taiwan
[8] Kaohsiung Med Univ, Coll Med, Fac Med, Dept Otolaryngol, Kaohsiung, Taiwan
关键词
EMG endotracheal tube; Endotracheal tube displacement; Intraoperative neuromonitoring; Thyroid surgery; PITFALLS; INJURY; PLAUDITS; RISK;
D O I
10.1016/j.kjms.2010.08.002
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Intraoperative neuromonitoring (IONM) is widely used in thyroid surgery. This study aimed to investigate the influence of neck extension on electromyographic (EMG) endotracheal tube displacement and to determine the necessity of routinely checking the final electrode position after the patient had been fully positioned. A consecutive 220 patients undergoing thyroidectomy were enrolled. All patients were intubated with the EMG endotracheal tube under direct laryngoscopy. The electrode position and tube displacement were routinely checked and measured by laryngofiberoscopy before and after patient positioning. The patients were divided into two groups. In Group I (n=110), the EMG tube was taped and fixed to the right mouth angle before full neck extension. In Group II (n=110), the EMG tube was disconnected from the circuit tube and was not taped until full neck extension. In all patients, we ensured that the final electrode position was the optimal position with laryngofiberoscopic examination. The tube displacement after neck extension ranged from 16 mm upward to 4 mm downward in Group I and from 12 mm upward to 5 mm downward in Group II. The rate of tube displacement greater than 10 mm was 12.7% in Group I and 3.6% in Group II. Successful monitoring was achieved in all patients after the final optimal position of electrodes was ensured routinely. The electrode position can be severely displaced after the patient has been fully positioned. Verification of ideal position of electrodes before the beginning of the operation is a necessary step to guarantee functional intraoperative neuromonitoring. (sic) Copyright (C) 2011, Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [1] Influence of intravenous anesthetics on neuromonitoring of the recurrent laryngeal nerve during thyroid surgery
    Chang, Pi-Ying
    Wu, Che-Wei
    Chen, Hsiu-Ya
    Chen, Hui-Chun
    Cheng, Kuang-I
    Lu, I-Cheng
    Chiang, Feng-Yu
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2014, 30 (10) : 499 - 503
  • [2] Practical comments on recurrent laryngeal nerve neuromonitoring during thyroid surgery
    Masiak-Segit, Wioletta
    Dabrowski, Andrzej
    Abramowicz, Krystyna
    Jaworski, Tomasz Jerzy
    Wallner, Grzegorz
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA-POLISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 10 (04) : 374 - 379
  • [3] INTRAOPERATIVE NEUROMONITORING FOR EARLY LOCALIZATION AND IDENTIFICATION OF RECURRENT LARYNGEAL NERVE DURING THYROID SURGERY
    Chiang, Feng-Yu
    Lu, I-Cheng
    Chen, Hui-Chun
    Chen, Hsiu-Ya
    Tsai, Cheng-Jing
    Lee, Ka-Wo
    Hsiao, Pi-Jung
    Wu, Che-Wei
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2010, 26 (12) : 633 - 639
  • [4] Intraoperative Neuromonitoring of the Recurrent Laryngeal Nerve in Robotic Thyroid Surgery
    Bae, Dong Sik
    Kim, Su-Jin
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2015, 25 (01) : 23 - 26
  • [5] Standardization of Intraoperative Neuromonitoring of Recurrent Laryngeal Nerve in Thyroid Operation
    Chiang, Feng-Yu
    Lee, Ka-Wo
    Chen, Hui-Chun
    Chen, Hsiu-Ya
    Lu, I-Cheng
    Kuo, Wen-Rei
    Hsieh, Ming-Chia
    Wu, Che-Wei
    WORLD JOURNAL OF SURGERY, 2010, 34 (02) : 223 - 229
  • [6] ANATOMICAL VARIATIONS OF RECURRENT LARYNGEAL NERVE DURING THYROID SURGERY: How TO IDENTIFY AND HANDLE THE VARIATIONS WITH INTRAOPERATIVE NEUROMONITORING
    Chiang, Feng-Yu
    Lu, I-Cheng
    Chen, Hui-Chun
    Chen, Hsiu-Ya
    Tsai, Cheng-Jing
    Hsiao, Pi-Jung
    Lee, Ka-Wo
    Wu, Che-Wei
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2010, 26 (11) : 575 - 583
  • [7] Evaluating the introduction of intraoperative neuromonitoring of the recurrent laryngeal nerve in thyroid and parathyroid surgery
    Wojtczak, Beata
    Kaliszewski, Krzysztof
    Sutkowski, Krzysztof
    Glod, Mateusz
    Barczynski, Marcin
    ARCHIVES OF MEDICAL SCIENCE, 2018, 14 (02) : 321 - 328
  • [8] Influence of muscle relaxation on neuromonitoring of the recurrent laryngeal nerve during thyroid surgery
    Marusch, F
    Hussock, J
    Haring, G
    Hachenberg, T
    Gastinger, I
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (05) : 596 - 600
  • [9] Role of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid and parathyroid surgery
    Ling, Yuwei
    Zhao, Jing
    Zhao, Ye
    Li, Kaifu
    Wang, Yajun
    Kang, Hua
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (09)
  • [10] Vagal nerve stimulation without dissecting the carotid sheath during intraoperative neuromonitoring of the recurrent laryngeal nerve in thyroid surgery
    Wu, Che-Wei
    Dionigi, Gianlorenzo
    Chen, Hui-Chun
    Chen, Hsiu-Ya
    Lee, Ka-Wo
    Lu, I-Cheng
    Chang, Pi-Ying
    Hsiao, Pi-Jung
    Ho, Kuen-Yao
    Chiang, Feng-Yu
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2013, 35 (10): : 1443 - 1447