Micro-imaging performance of multilayers used as monochromators for coherent hard X-ray synchrotron radiation

被引:13
作者
Rack, A. [1 ]
Weitkamp, T. [1 ]
Riotte, M. [2 ]
Rack, T. [2 ]
Dietsch, R. [3 ]
Holz, T. [3 ]
Kraemer, M.
Siewert, F. [4 ]
Meduna, M. [5 ]
Morawe, Ch. [1 ]
Cloetens, P. [1 ]
Ziegler, E. [1 ]
机构
[1] European Synchrotron Radiat Facil, BP 220, F-38043 Grenoble, France
[2] Karlsruhe Inst Technol ANKA, D-76021 Karlsruhe, Germany
[3] AXO Dresden GmbH, D-01809 Heidenau, Germany
[4] Helmholtz Zentrum Berlin BESSY II, D-12489 Berlin, Germany
[5] Masaryk Univ, CS-61137 Brno, Czech Republic
来源
ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS V | 2010年 / 7802卷
关键词
Multilayer mirrors; X-ray imaging; coherence; synchrotron radiation; X-ray monochromators; X-ray phase contrast; X-ray optics; TOMOGRAPHY; BEAMLINE;
D O I
10.1117/12.858355
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a systematic study in which multilayers of different composition (W/Si, Mo/Si, Pd/B4C), periodicity (from 2.5 to 5.5 nm), and numbers of layers have been characterised. Particularly, we investigated the intrinsic quality (roughness and reflectivity) as well as the performance (flatness and coherence of the outgoing beam) as a monochromator for synchrotron radiation hard X-ray micro-imaging. The results indicate that the material composition is the dominating factor for the performance. This is of high importance for synchrotron-based hard X-ray imaging which has become a widely applied tool for probing the microstructure of bulk samples. The high spatial resolution and different contrast modalities available here strongly depend on using coherent beams from highly brilliant sources. In order to satisfy the demand for a high flux of quasi-monochromatic photons, multilayer-coated mirrors are commonly used as monochromators. Their properties present a good tradeoff between spectral bandwidth and photon flux density. Since the photon flux density at the sample position is higher than with standard crystal monochromators, better spatial resolution can be reached. This comes at the cost of reduced energy resolution and stronger non-uniformities in the incoming beam profile. By helping scientists and engineers specify the design parameters of multilayer monochromators, our results can contribute to a better exploitation of the advantages of multilayer monochromators over crystal-based devices; i.e., larger spectral bandwidth and high photon flux density for X-ray imaging.
引用
收藏
页数:7
相关论文
共 28 条
  • [11] The new ESRF multilayer deposition facility
    Morawe, Ch.
    Borel, Ch.
    Peffen, J-Ch.
    [J]. ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS II, 2007, 6705
  • [12] High resolution synchrotron-based radiography and tomography using hard X-rays at the BAMline (BESSY II)
    Rack, A.
    Zabler, S.
    Mueller, B. R.
    Riesemeier, H.
    Weldemann, G.
    Lange, A.
    Goebbels, J.
    Hentschel, M.
    Goerner, W.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 586 (02) : 327 - 344
  • [13] Comparative study of multilayers used in monochromators for synchrotron-based coherent hard X-ray imaging
    Rack, A.
    Weitkamp, T.
    Riotte, M.
    Grigoriev, D.
    Rack, T.
    Helfen, L.
    Baumbach, T.
    Dietsch, R.
    Holz, T.
    Kraemer, M.
    Siewert, F.
    Meduna, M.
    Cloetens, P.
    Ziegler, E.
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2010, 17 : 496 - 510
  • [14] The micro-imaging station of the TopoTomo beamline at the ANKA synchrotron light source
    Rack, A.
    Weitkamp, T.
    Trabelsi, S. Bauer
    Modregger, P.
    Cecilia, A.
    Rolo, T. dos Santos
    Rack, T.
    Haas, D.
    Simon, R.
    Heldele, R.
    Schulz, M.
    Mayzel, B.
    Danilewsky, A. N.
    Waterstradt, T.
    Diete, W.
    Riesemeier, H.
    Mueller, B. R.
    Baumbach, T.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (11) : 1978 - 1988
  • [15] Fully automated, fixed exit, in vacuum double-multilayer monochromator for synchrotron-based hard X-ray micro-imaging applications
    Rack, Alexander
    Riesemeier, Heinrich
    Vagovic, Patrik
    Weitkamp, Timm
    Siewert, Frank
    Dietsch, Reiner
    Dieter, Wolfgang
    Trabelsi, Sondes Bauer
    Waterstradt, Timm
    Baumbach, Tilo
    [J]. SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 740 - +
  • [16] The high resolution synchrotron-based imaging stations at the BAMline (BESSY) and TopoTomo (ANKA)
    Rack, Alexander
    Riesemeier, Heinrich
    Zabler, Simon
    Weitkamp, Timm
    Mueller, Bernd R.
    Weidemann, Gerd
    Modregger, Peter
    Barthart, John
    Helfen, Lukas
    Danilewsky, Andreas N.
    Graeber, Hans G.
    Heldele, Richard
    Mayzel, Boaz
    Goebbels, Juergen
    Baumbach, Tilo
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [17] Sawhney K. J. S., 2010, COMMUNICATION
  • [18] Siewert F, 2004, AIP CONF PROC, V705, P847, DOI 10.1063/1.1757928
  • [19] Characterization and calibration of 2nd generation slope measuring profiler
    Siewert, Frank
    Buchheim, Jana
    Zeschke, Thomas
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 616 (2-3) : 119 - 127
  • [20] Reduction of ring artefacts in high resolution micro-CT reconstructions
    Sijbers, J
    Postnov, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14) : N247 - N253