Estimation of Heart Rate and Energy Expenditure Using a Smart Bracelet during Different Exercise Intensities: A Reliability and Validity Study

被引:5
作者
Cai, Yihui [1 ]
Wang, Zi [1 ]
Zhang, Wanxia [1 ]
Kong, Weiya [1 ]
Jiang, Jiayao [1 ]
Zhao, Ruobing [1 ]
Wang, Dongxue [1 ]
Feng, Leyi [2 ]
Ni, Guoxin [1 ]
机构
[1] Beijing Sport Univ, Sch Sports Med & Rehabil, Beijing 100084, Peoples R China
[2] Beijing Sport Univ, Sch Sport Sci, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
exercise; wrist-worn devices; monitoring; energy expenditure; heart rate; reliability; validation; PHYSICAL-ACTIVITY; ACTIVITY MONITORS; ADULTS;
D O I
10.3390/s22134661
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background. With wrist-worn wearables becoming increasingly available, it is important to understand their reliability and validity in different conditions. The primary objective of this study was to examine the reliability and validity of the Lexin Mio smart bracelet in measuring heart rate (HR) and energy expenditure (EE) in people with different physical activity levels exercising at different intensities. Methods. A total of 65 participants completed one maximal oxygen uptake test and two running exercise tests wearing the Mio smart bracelet, the Polar H10 HR band, and a gas-analysis system. Results. In terms of HR measurement reliability, the Mio smart bracelet showed good reliability in a left versus right test and good test-retest reliability (p > 0.05; mean absolute percentage error (MAPE) < 10%; intraclass correlation coefficient (ICC) > 0.4). For EE measurement, the Mio smart bracelet showed good reliability in a left versus right test, good test-retest reliability on the right (p > 0.05; MAPE > 10%; ICC > 0.4), and low test-retest reliability on the left (p > 0.05; MAPE > 10%; ICC < 0.4). Regarding validity, the Mio smart bracelet showed good validity for HR measurement (p > 0.05; MAPE < 10%; ICC > 0.4) and low validity for EE measurement (p < 0.05; MAPE > 10%; ICC < 0.4). Conclusion. The Lexin Mio smart bracelet showed good reliability and validity for HR measurement among people with different physical activity levels exercising at various exercise intensities in a laboratory setting. However, the smart bracelet showed good reliability and low validity for the estimation of EE.
引用
收藏
页数:21
相关论文
共 48 条
  • [1] Using Accelerometer and GPS Data for Real-Life Physical Activity Type Detection
    Allahbakhshi, Hoda
    Conrow, Lindsey
    Naimi, Babak
    Weibel, Robert
    [J]. SENSORS, 2020, 20 (03)
  • [2] A comparison of dominant and non-dominant hand strengths
    Armstrong, CA
    Oldham, JA
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1999, 24B (04) : 421 - 425
  • [3] Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HR
    Bai, Yang
    Hibbing, Paul
    Mantis, Constantine
    Welk, Gregory J.
    [J]. JOURNAL OF SPORTS SCIENCES, 2018, 36 (15) : 1734 - 1741
  • [4] PSYCHOPHYSICAL BASES OF PERCEIVED EXERTION
    BORG, GAV
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1982, 14 (05) : 377 - 381
  • [5] Validity of Wearable Activity Monitors during Cycling and Resistance Exercise
    Boudreaux, Benjamin D.
    Hebert, Edward P.
    Hollander, Daniel B.
    Williams, Brian M.
    Cormier, Corinne L.
    Naquin, Mildred R.
    Gillan, Wynn W.
    Gusew, Emily E.
    Kraemer, Robert R.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (03) : 624 - 633
  • [6] Cicchetti DV., 1994, PSYCHOL ASSESSMENTS, V6, P284, DOI [10.1037/1040-3590.6.4.284, DOI 10.1037/1040-3590.6.4.284]
  • [7] A Comparison of Energy Expenditure Estimation of Several Physical Activity Monitors
    Dannecker, Kathryn L.
    Sazonova, Nadezhda A.
    Melanson, Edward L.
    Sazonov, Edward S.
    Browning, Raymond C.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (11) : 2105 - 2112
  • [8] Delgado-Gonzalo R, 2015, IEEE ENG MED BIO, P430, DOI 10.1109/EMBC.2015.7318391
  • [9] Physical activity using wrist-worn accelerometers: comparison of dominant and non-dominant wrist
    Dieu, Olivier
    Mikulovic, Jacques
    Fardy, Paul S.
    Bui-Xuan, Gilles
    Beghin, Laurent
    Vanhelst, Jeremy
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2017, 37 (05) : 525 - 529
  • [10] Dooley Erin E, 2017, JMIR Mhealth Uhealth, V5, pe34, DOI 10.2196/mhealth.7043