Wear Comparison Between a Highly Cross-Linked Polyethylene and Conventional Polyethylene Against a Zirconia Femoral Head Minimum 5-Year Follow-Up

被引:17
作者
Fukui, Kiyokazu [1 ]
Kaneuji, Ayumi [1 ]
Sugimori, Tanzo [1 ]
Ichiseki, Toru [1 ]
Kitamura, Kenji [1 ]
Matsumoto, Tadami [1 ]
机构
[1] Kanazawa Med Univ, Dept Orthoped Surg, Kanazawa, Ishikawa, Japan
关键词
cross-linked polyethylene; polyethylene wear; total hip arthroplasty; zirconia femoral head; TOTAL HIP-ARTHROPLASTY; CERAMIC HEAD; RADIOSTEREOMETRIC ANALYSIS; UNCEMENTED SOCKETS; ALUMINA; FRACTURE; JOINTS; METAL; REPLACEMENT; SIMULATOR;
D O I
10.1016/j.arth.2009.11.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Highly cross-linked polyethylene (HXLPE) was developed to reduce wear of articular bearing surface in total hip arthroplasty patients. Several studies have shown reduced wear of HXLPE compared with conventional polyethylene; however, these studies had used HXLPE in combination with a Co-Cr metal head. The purpose of this study was to compare the 5-year in vivo wear of HXLPE with that of conventional PE using a zirconia femoral head. Forty-five hips with a Trilogy HXLPE (Zimmer, Warsaw, Ind) were matched and compared with a control group of 20 conventional Trilogy PE hips. The 2-dimensional linear wear rate was significantly less in the HXLPE group between 1 and 5 years postoperation (P < .001). The results show that HXLPE reduces short-term polyethylene wear against not only a Co-Cr head but also a zirconia head.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 50 条
  • [21] Differences in Femoral Head Penetration Between Highly Cross-Linked Polyethylene Cemented Sockets and Uncemented Liners
    Morita, Daigo
    Seki, Taisuke
    Higuchi, Yoshitoshi
    Takegami, Yasuhiko
    Ishiguro, Naoki
    JOURNAL OF ARTHROPLASTY, 2017, 32 (12) : 3796 - 3801
  • [22] In vivo wear performance of highly cross-linked polyethylene vs. yttria stabilized zirconia and alumina stabilized zirconia at a mean seven-year follow-up
    Masahiro Hasegawa
    Akihiro Sudo
    BMC Musculoskeletal Disorders, 14
  • [23] Low Wear at 10-Year Follow-Up of a Second-Generation Highly Cross-Linked Polyethylene in Total Hip Arthroplasty
    Sax, Oliver C.
    Douglas, Scott J.
    Chen, Zhongming
    Mont, Michael A.
    Nace, James
    Delanois, Ronald E.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (07) : S592 - S597
  • [24] Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty?
    Glyn-Jones, Sion
    Saac, Sherif
    Hauptfleisch, Jennifer
    McLardy-Smith, Peter
    Murray, David W.
    Singh, Harinderjit
    JOURNAL OF ARTHROPLASTY, 2008, 23 (03) : 337 - 343
  • [25] Up to 18-Year Follow-Up Wear Analysis of a First-Generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty
    Feng, James E.
    Novikov, David
    Chen, Kevin
    Kim, Kelvin
    Bookman, Jared
    Anoushiravani, Afshin A.
    Hamula, Matthew
    Snir, Nimrod
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2018, 33 (10) : 3325 - 3328
  • [26] 10-Year Follow-Up Wear Analysis of Marathon Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty
    Bookman, Jared S.
    Kaye, Ian D.
    Chen, Kevin K.
    Jaffe, Fredrick F.
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2017, 32 (08) : 2587 - 2589
  • [27] Ten-to Sixteen-Year Follow-Up of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: What Factors Affect Wear?
    Cheung, Amy
    Yan, Chun Hoi
    Fu, Henry
    Cheung, Man Hong
    Chan, Ping Keung
    Chiu, Kwong Yuen
    JOURNAL OF ARTHROPLASTY, 2019, 34 (09) : 2016 - 2021
  • [28] Wear Rates With Large Metal and Ceramic Heads on a Second Generation Highly Cross-Linked Polyethylene at Mean 6-Year Follow-Up
    Gaudiani, Michael A.
    White, Peter B.
    Ghazi, Narges
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02) : 590 - 594
  • [29] Ceramic femoral head in highly cross-linked polyethylene cup. 5 year results of a randomized trial
    Peker, Gokhan
    Bala, Mehmet Murat
    Altun, Ibrahim
    ANNALI ITALIANI DI CHIRURGIA, 2022, 93 (02) : 202 - 209
  • [30] Thirteen-year results of cementless total hip arthroplasty with zirconia heads on highly cross-linked polyethylene
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    MODERN RHEUMATOLOGY, 2021, 31 (05) : 1045 - 1049