JY1 time scale: a new Kalman-filter time scale designed at NIST

被引:8
作者
Yao, Jian [1 ,2 ]
Parker, Thomas E. [1 ]
Levine, Judah [1 ,2 ]
机构
[1] NIST, Div Time & Frequency, Boulder, CO 80303 USA
[2] Univ Colorado Boulder, Dept Phys, Boulder, CO 80309 USA
关键词
time scale; Kalman filter; atomic clock; hydrogen maser; cesium fountain clock; UTC; TIMESCALES;
D O I
10.1088/1361-6501/aa8373
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We report on a new Kalman-filter hydrogen-maser time scale (i.e. JY1 time scale) designed at the National Institute of Standards and Technology (NIST). The JY1 time scale is composed of a few hydrogen masers and a commercial Cs clock. The Cs clock is used as a reference clock to ease operations with existing data. Unlike other time scales, the JY1 time scale uses three basic time-scale equations, instead of only one equation. Also, this time scale can detect a clock error (i.e. time error, frequency error, or frequency drift error) automatically. These features make the JY1 time scale stiff and less likely to be affected by an abnormal clock. Tests show that the JY1 time scale deviates from the UTC by less than +/- 5 ns for similar to 100 d, when the time scale is initially aligned to the UTC and then is completely free running. Once the time scale is steered to a Cs fountain, it can maintain the time with little error even if the Cs fountain stops working for tens of days. This can be helpful when we do not have a continuously operated fountain or when the continuously operated fountain accidentally stops, or when optical clocks run occasionally.
引用
收藏
页数:8
相关论文
共 13 条
  • [1] Generation of UTC(PTB) as a fountain-clock based time scale
    Bauch, A.
    Weyers, S.
    Piester, D.
    Staliuniene, E.
    Yang, W.
    [J]. METROLOGIA, 2012, 49 (03) : 180 - 188
  • [2] Breakiron L. A., 1991, P PTTI, V23, P297
  • [3] On the use of the Kalman filter in timescales
    Galleani, L
    Tavella, P
    [J]. METROLOGIA, 2003, 40 (03) : S326 - S334
  • [4] Galleani L, 2010, IEEE CONTR SYST MAG, V30, P44, DOI 10.1109/MCS.2009.935568
  • [5] Gelb A., 1989, Applied Optimal Estimation
  • [6] Forming stable timescales from the Jones-Tryon Kalman filter
    Greenhall, CA
    [J]. METROLOGIA, 2003, 40 (03) : S335 - S341
  • [7] A Review of Reduced Kalman Filters for Clock Ensembles
    Greenhall, Charles A.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (03) : 491 - 496
  • [8] Greenhall CharlesA., 2001, Proceedings of the 33th Annual Precise Time and Time Interval Systems and Applications Meeting, V33, P445
  • [9] Accuracy evaluation of NIST-F1
    Jefferts, SR
    Shirley, J
    Parker, TE
    Heavner, TP
    Meekhof, DM
    Nelson, C
    Levi, F
    Costanzo, G
    De Marchi, A
    Drullinger, R
    Hollberg, L
    Lee, WD
    Walls, FL
    [J]. METROLOGIA, 2002, 39 (04) : 321 - 336
  • [10] Invited Review Article: The statistical modeling of atomic clocks and the design of time scales
    Levine, Judah
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02)