Cascaded systems analysis of anatomic noise in digital mammography and dual-energy digital mammography

被引:6
作者
Tanguay, Jesse [1 ]
Lalonde, Robert [1 ]
Bjarnason, Thorarin A. [2 ,3 ,4 ]
Yang, Chang-Ying Joseph [2 ,5 ]
机构
[1] Ryerson Univ, Dept Phys, Toronto, ON, Canada
[2] Univ British Columbia Okanagan, Dept Phys, Kelowna, BC, Canada
[3] Interior Hlth, Med Imaging, Kelowna, BC, Canada
[4] Univ British Columbia, Dept Radiol, Vancouver, BC, Canada
[5] BC Canc Kelowna, Kelowna, BC, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
mammography; breast imaging; image quality; noise power spectrum; medical imaging; dual-energy imaging; DETECTIVE QUANTUM EFFICIENCY; OPTIMIZATION; TOMOSYNTHESIS; SIGNAL; MODEL; DETECTABILITY; PROPAGATION; VALIDATION; PARAMETERS; SPECTRA;
D O I
10.1088/1361-6560/ab3fcd
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In x-ray based imaging of the breast, contrast between fibroglandular (Fg) tissue and adipose (Ad) tissue is a source of anatomic noise. The goal of this work was to validate by simulation and experiment a mathematical framework for modelling the Fg component of anatomic noise in digital mammograpy (DM) and dual-energy (DE) DM. Our mathematical framework unifies and generalizes existing approaches. We compared mathematical predictions directly with empirical measurements of the anatomic noise power spectrum of the CIRS BR3D structured breast phantom using two clinical mammography systems and four beam qualities. Our simulation and experimental results showed agreement with mathematical predictions. As a demonstration of utility, we used our mathematical framework in a theoretical spectral optimization of DM for the task of detecting breast masses. Our theoretical optimization showed that the optimal tube voltage for DM may be higher than that based on predictions that do not account for anatomic noise, in agreement with recent theoretical findings. Additionally, our theoretical optimization predicts that filtering tungsten-anode x-ray spectra with rhodium has little influence on lesion detectability, in contrast with previous findings. The mathematical methods validated in this work can be incorporated easily into cascaded systems analysis of breast imaging systems and will be useful when optimizating novel techniques for x-ray-based imaging of the breast.
引用
收藏
页数:21
相关论文
共 50 条
[21]   A novel approach to background subtraction in contrast-enhanced dual-energy digital mammography with commercially available mammography devices: Polychromaticity correction [J].
Contillo, Adriano ;
Di Domenico, Giovanni ;
Cardarelli, Paolo ;
Gambaccini, Mauro ;
Taibi, Angelo .
MEDICAL PHYSICS, 2015, 42 (11) :6641-6650
[22]   Cascaded systems analysis of noise reduction algorithms in dual-energy imaging [J].
Richard, Samuel ;
Siewerdsen, Jeffrey H. .
MEDICAL PHYSICS, 2008, 35 (02) :586-601
[23]   Scatter-to-primary ratio and grid performance in contrast-enhanced dual-energy digital mammography using Monte Carlo simulations [J].
Cunha, D. M. ;
Godeli, J. ;
Poletti, M. E. .
RADIATION PHYSICS AND CHEMISTRY, 2025, 232
[24]   A comprehensive model for quantum noise characterization in digital mammography [J].
Monnin, P. ;
Bosmans, H. ;
Verdun, F. R. ;
Marshall, N. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (05) :2083-2108
[25]   Digital Mammography and Digital Breast Tomosynthesis [J].
Moseley, Tanya W. .
CLINICAL OBSTETRICS AND GYNECOLOGY, 2016, 59 (02) :362-379
[26]   Dual-energy mammography simulation: Optimisation studies [J].
Bliznakova, K. ;
Kolitsi, Z. ;
Pallikarakis, N. .
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 :1617-+
[27]   Performance evaluation of six digital mammography systems [J].
Perez, Alessandra Maia Marques Martinez ;
Lopes, Laura Alcantara Silva ;
Caron, Renato Franca ;
Oliveira, Bruno Beraldo ;
Poletti, Martin Eduardo .
RADIATION PHYSICS AND CHEMISTRY, 2024, 218
[28]   Anatomical noise in contrast-enhanced digital mammography. Part I. Single-energy imaging [J].
Hill, Melissa L. ;
Mainprize, James G. ;
Carton, Ann-Katherine ;
Muller, Serge ;
Ebrahimi, Mehran ;
Jong, Roberta A. ;
Dromain, Clarisse ;
Yaffe, Martin J. .
MEDICAL PHYSICS, 2013, 40 (05)
[29]   Postmortem validation of breast density using dual-energy mammography [J].
Molloi, Sabee ;
Ducote, Justin L. ;
Ding, Huanjun ;
Feig, Stephen A. .
MEDICAL PHYSICS, 2014, 41 (08) :439-448
[30]   Comparing the performance of digital mammography systems [J].
Young, Kenneth C. ;
Oduko, Jennifer M. ;
Gundogdu, Ozcan ;
Alsager, Abdulaziz .
DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 :732-+