Analytical formulation for the shielding effectiveness of enclosures with apertures

被引:367
作者
Robinson, MP [1 ]
Benson, TM
Christopoulos, C
Dawson, JF
Ganley, MD
Marvin, AC
Porter, SJ
Thomas, DWP
机构
[1] Univ York, Dept Elect, York Y010 5DD, N Yorkshire, England
[2] Univ Nottingham, Dept Elect & Elect Engn, Nottingham NG7 2RD, England
基金
英国工程与自然科学研究理事会;
关键词
apertures; circuit modeling; electromagnetic compatibility; electrical equipment enclosures; electromagnetic shielding;
D O I
10.1109/15.709422
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An analytical formulation has been developed for the shielding effectiveness of a rectangular enclosure with an aperture. Both the magnetic and electric shielding may be calculated as a function of frequency, enclosure dimensions, aperture dimensions and position within the enclosure. Theoretical values of shielding effectiveness are in good agreement with measurements. The theory has been extended to account for circular apertures, multiple apertures, and the effect of the enclosure contents.
引用
收藏
页码:240 / 248
页数:9
相关论文
共 18 条
  • [1] Theory of diffraction by small holes
    Bethe, HA
    [J]. PHYSICAL REVIEW, 1944, 66 (7/8): : 163 - 182
  • [2] THEORETICAL AND EXPERIMENTAL EVALUATION OF THE ELECTROMAGNETIC-RADIATION FROM APERTURES IN SHIELDED ENCLOSURES
    CERRI, G
    DELEO, R
    PRIMIANI, VM
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1992, 34 (04) : 423 - 432
  • [3] DAWSON JF, 1992, IEE CONF PUBL, V362, P207
  • [4] FIELD JCG, 1983, I EL ENG C SCREENING
  • [5] Gupta K C, 1979, MICROSTRIP LINES SLO
  • [6] APERTURE EXCITATION OF ELECTRICALLY LARGE, LOSSY CAVITIES
    HILL, DA
    MA, MT
    ONDREJKA, AR
    RIDDLE, BF
    CRAWFORD, ML
    JOHNK, RT
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1994, 36 (03) : 169 - 178
  • [7] *INT EL COMM, 1984, 801 IEC
  • [8] KADEN H, 1959, WIRGELSTROME SCHIRMU
  • [9] KRAFT CH, 1994, IEEE INT S EL COMP C, P73
  • [10] Kunz K. S., 1993, FINITE DIFFERENCE TI