Population exposure-response model of 131I in patients with benign thyroid disease

被引:1
|
作者
Vucenovic, Valentina Topic [1 ,2 ]
Rajkovaca, Zvezdana [3 ]
Jelic, Dijana [4 ]
Stanimirovic, Dragi [3 ]
Mikov, Momir [5 ]
Miljkovic, Branislava [2 ]
Vucicevic, Katarina [2 ]
机构
[1] Univ Banja Luka, Fac Med, Dept Pharm, Save Mrkalja 14, Banja Luka 78000, Bosnia & Herceg
[2] Univ Belgrade, Dept Phammcokinet & Clin Pharm, Fac Pharm, Vojvode Stepe 450, Belgrade 11221, Serbia
[3] Univ Clin Ctr Republ Srpska, Inst Nucl Med & Thyroid Gland Dis, 12 Beba Bb, Banja Luka 78000, Bosnia & Herceg
[4] Univ Banja Luka, Fac Nat Sci & Math, Chem Dept, Mladena Stojanovica 2, Banja Luka 78000, Bosnia & Herceg
[5] Univ Novi Sad, Dept Pharmacol Toxicol & Clin Pharmacol, Fac Med, Hajduk Veljkova 3, Novi Sad 21000, Serbia
关键词
Radioiodine therapy; Outcome probability; Biologically effective dose; Benign thyroid disorders; Proportional odds model; Dose-rate effects; RADIOIODINE THERAPY; GRAVES-DISEASE; DOSE-RATE; DOSIMETRY; HYPERTHYROIDISM; HYPOTHYROIDISM; EFFICACY; SCHEMA;
D O I
10.1016/j.ejps.2021.105942
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose: The study aimed to explore the relationship of different exposure measures with 131I therapy response in patients with benign thyroid disease, estimate the variability in the response, investigate possible covariates, and discuss dosing implications of the results. Methods: A population exposure-response analysis was performed using nonlinear mixed-effects modelling. Data from 95 adult patients with benign thyroid disease were analysed. Evaluated exposure parameters were: administered radioactivity dose (Aa) [MBq], total absorbed dose (ABD) [Gy], maximum of absorbed dose-rate (MXR) [Gy/h] and biologically effective dose (BED) [Gy]. The response was modelled as ordered categorical data: hyper-, eu- and hypothyroidism. The final model performance was evaluated by a visual predictive check. Results: The probability of the outcome following 131I therapy was best described by a proportional-odds model, including the log-linear model of 131I effect and the exponential model of the response-time relationship. All exposure measures were statistically significant with p<0.001, with BED and ABD being statistically better than the other two. Nevertheless, as BED resulted in the lowest AIC value, it was included in the final model. Accordingly, BED value of 289.7 Gy is associated with 80% probability of successful treatment outcome 12 months after 131I application in patients with median thyroid volume (32.28 mL). The target thyroid volume was a statistically significant covariate. The visual predictive check of the final model showed good model performance. Conclusion: Our results imply that BED formalism could aid in therapy individualisation. The larger thyroid volume is associated with a lower probability of a successful outcome.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Comparing pre-therapeutic 124I and 131I uptake tests with intra-therapeutic 131I uptake in benign thyroid disorders
    Guhne, Falk
    Kuhnel, Christian
    Freesmeyer, Martin
    ENDOCRINE, 2017, 56 (01) : 43 - 53
  • [2] Transcriptional response to 131I exposure of rat thyroid gland
    Rudqvist, Nils
    Spetz, Johan
    Schuler, Emil
    Parris, Toshima Z.
    Langen, Britta
    Helou, Khalil
    Forssell-Aronsson, Eva
    PLOS ONE, 2017, 12 (02):
  • [3] Radioiodine therapy of benign thyroid disorders: what are the effective thyroidal half-life and uptake of 131I?
    Kobe, Carsten
    Eschner, Wolfgang
    Wild, Markus
    Rahlff, Ilka
    Sudbrock, Ferdinand
    Schmidt, Matthias
    Dietlein, Markus
    Schicha, Harald
    NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (03) : 201 - 205
  • [4] Determining thyroid 131I effective half-life for the treatment planning of Graves' disease
    Willegaignon, Jose
    Sapienza, Marcelo T.
    Coura Filho, George Barberio
    Traino, Antonio C.
    Buchpiguel, Carlos A.
    MEDICAL PHYSICS, 2013, 40 (02)
  • [5] Dosimetric methodology for 131I therapy for benign thyroid diseases
    Piron, B.
    Broggio, D.
    Bardies, M.
    Barrau, C.
    Kotzki, P. O.
    Boudousq, V
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2020, 44 (04): : 261 - 266
  • [6] Investigation of factors influencing radioiodine (131I) biokinetics in patients with benign thyroid disease using nonlinear mixed effects approach
    Vucenovic, Valentina Topic
    Rajkovaca, Zvezdana
    Jelic, Dijana
    Stanimirovic, Dragi
    Vuleta, Goran
    Miljkovic, Branislava
    Vucicevic, Katarina
    EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 2018, 74 (08) : 1037 - 1045
  • [7] Pretherapeutic dosimetry before 131I therapy of benign thyroid disease A clinical practice assessment of dosimetric parameters
    Krohn, T.
    Behrendt, F. F.
    Heinzel, A.
    Mueller, B.
    Mottaghy, F. M.
    Verburg, F. A.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2015, 54 (03): : 131 - 136
  • [8] A new method to evaluate the residual activity in patients undergoing 131I thyroid therapy
    Ostinelli, A.
    Duchini, M.
    Conti, V.
    Bonfanti, P.
    Rossi, S.
    Cacciatori, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 1108 - 1111
  • [9] The success of 131I ablation in thyroid cancer patients is significantly reduced after a diagnostic activity of 40 MBq 131I
    Verburg, F. A.
    Verkooijen, R. B. T.
    Stokkel, M. P. M.
    van Isselt, J. W.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2009, 48 (04): : 138 - 142
  • [10] Predictive Factors of Outcomes in Personalized Radioactive Iodine (131I) Treatment for Graves' Disease
    Liu, Min
    Jing, Danqing
    Hu, Jingsheng
    Yin, Shinan
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2014, 348 (04) : 288 - 293