Feasibility of Vertical Rainwater Harvesting via In-situ Measurement of Wind-driven Rain Loads on Building Facades in a Tropical Climate

被引:2
|
作者
Samzadeh, Mozhgan [1 ]
Din, Nazli Che [2 ]
Abdullah, Zunaibi [2 ]
Ismail, Muhammad Azzam [2 ]
Mahyuddin, Norhayati [3 ]
机构
[1] Univ Malaya, Fac Built Environm, Jln Prof Diraja Ungku Aziz, Kuala Lumpur 50603, Malaysia
[2] Univ Malaya, Fac Built Environm, Dept Architecture, Jln Prof Diraja Ungku Aziz, Kuala Lumpur 50603, Malaysia
[3] Univ Malaya, Fac Built Environm, Dept Bldg Surveying, Jln Prof Diraja Ungku Aziz, Kuala Lumpur 50603, Malaysia
关键词
Wind-driven rain; Vertical Rainwater harvesting; Building facade; Measurement data; Monsoon wind; PRECIPITATION;
D O I
10.11113/ijbes.v8.n3.736
中图分类号
TU98 [区域规划、城乡规划];
学科分类号
0814 ; 082803 ; 0833 ;
摘要
Rainwater is an alternative water resource to fulfill sustainable management of freshwater particularly in the regions receive abundant annual amounts of precipitation such as tropical Malaysia. To collect and store rainwater, rainwater harvesting system has been practiced since ancient from horizontal surfaces mostly rooftop of buildings in urban areas. Nowadays, this method in modern urban areas with tall buildings is considered inadequate and uneconomical because the ratio of facade surface areas is much higher than the ratio of roof surface areas. On the other hand, all rain has a horizontal velocity due to wind acting upon rain droplets which is called wind-driven rain (WDR). Growing tall buildings and the presence of WDR phenomenon make building facade surfaces the available promising surfaces to harvest substantial rainwater vertically and more efficiently. This article presents a one-year field measurement results that aims at quantifying the WDR loads impinged on the vertical facade areas of a pilot building located at the main campus of the University Malaya in Kuala Lumpur, Malaysia. Detailed descriptions of the gauge design, building, the measurements of on-site WDR, rainfall duration time, and weather data are presented. Records show that monsoon winds characteristics have significant influence on the WDR loads on the building facades compare to horizontal rainfall intensity. Finally, the collected in-situ data are exploited to validate data and determine WDR coefficient (gamma) to estimate the amount of WDR on a building facade via an empirical WDR relationship. Results show the feasibility of each square meter of vertical facade area to supply 12% of non-potable or 4.9% of potable water-usage per capita per day. (C) 2021 Penerbit UTM Press. All rights reserved
引用
收藏
页码:27 / 45
页数:19
相关论文
共 26 条
  • [1] Future moisture loads for building facades in Sweden: Climate change and wind-driven rain
    Nik, Vahid M.
    Mundt-Petersen, S. Olof
    Kalagasidis, Angela Sasic
    De Wilde, Pieter
    BUILDING AND ENVIRONMENT, 2015, 93 : 362 - 375
  • [2] Comparison of calculation models for wind-driven rain deposition on building facades
    Blocken, B.
    Dezso, G.
    van Beeck, J.
    Carmeliet, J.
    ATMOSPHERIC ENVIRONMENT, 2010, 44 (14) : 1714 - 1725
  • [3] Numerical modeling of turbulent dispersion for wind-driven rain on building facades
    A. Kubilay
    D. Derome
    B. Blocken
    J. Carmeliet
    Environmental Fluid Mechanics, 2015, 15 : 109 - 133
  • [4] Numerical modeling of turbulent dispersion for wind-driven rain on building facades
    Kubilay, A.
    Derome, D.
    Blocken, B.
    Carmeliet, J.
    ENVIRONMENTAL FLUID MECHANICS, 2015, 15 (01) : 109 - 133
  • [5] Large Eddy Simulations of Wind-Driven Rain on Tall Building Facades
    Huang, S. H.
    Li, Q. S.
    JOURNAL OF STRUCTURAL ENGINEERING, 2012, 138 (08) : 967 - 983
  • [6] A combined CFD-HAM approach for wind-driven rain on building facades
    Blocken, Bert
    Roels, Staf
    Carmeliet, Jan
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2007, 95 (07) : 585 - 607
  • [7] Observation Experiment of Wind-Driven Rain Harvesting from a Building Wall
    Yoo, Chulsang
    Cho, Eunsaem
    Lee, Munseok
    Kim, Soeun
    WATER, 2022, 14 (04)
  • [8] Numerical simulation of wind-driven rain distribution on building facades under combination layout
    Wang, Hui
    Song, Wenhui
    Chen, Yusheng
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2019, 188 : 375 - 383
  • [9] Simulating wind-driven rain on building facades using Eulerian multiphase with rain phase turbulence model
    Pettersson, K.
    Krajnovic, S.
    Kalagasidis, A. S.
    Johansson, P.
    BUILDING AND ENVIRONMENT, 2016, 106 : 1 - 9
  • [10] On the errors associated with the use of hourly data in wind-driven rain calculations on building facades
    Blocken, Bert
    Carmellet, Jan
    ATMOSPHERIC ENVIRONMENT, 2007, 41 (11) : 2335 - 2343