Trace impurities of Cd, Cu and Ph were determined in alumina based catalysts using direct solid sampling graphite furnace atomic absorption spectrometry (DSS-GF AAS). The analyzed catalysts are widely used in petrochemical processes. The following analytical parameters were evaluated: pyrolysis and atornization temperatures, feasibility of calibration with aqueous solutions, the necessity for palladium as chemical modifier and the sample mass introduced into the atomizer. Test samples between 0.05 and 8.5 mg were used. Palladium was investigated as chemical modifier but no improvement in analytical performance was obtained and its use was considered unnecessary for all elements. The results obtained by DSS-GF AAS were compared with those of inductively coupled plasma optical emission spectrometry (ICP OES) and also with conventional solution analysis by GF AAS (Sol-GF AAS). Characteristic masses were 1.4, 9 and 20 pg, for Cd, Cu arid Ph, respectively. Using DSS-GFAAS the relative standard deviation was always less than 10% and the results agreed with those obtained by Sol-GF AAS and ICP OES. Calibration using aqueous solutions showed good linearity within the working range (R-2 better than 0.99). Limits of detection (3 sigma, n = 10) for Cd, Cu and Ph using the proposed procedure were 0.2, 22, and 1.2 ng g(-1), respectively. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:933 / 938
页数:6
相关论文
共 23 条
[1]   Mechanisms of catalyst deactivation [J].
Bartholomew, CH .
APPLIED CATALYSIS A-GENERAL, 2001, 212 (1-2) :17-60
[2]   Direct determination of metals in solid samples by graphite-furnace atomic absorption spectrometry: Does sample mass influence the analytical results? [J].
Belarra, MA ;
Crespo, C ;
Martinez-Garbayo, MP ;
Castillo, JR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (12) :1855-1860
[3]  
DONOVAN JR, 1983, APPL CATAL, V2, P271
[4]   EFFECT OF COLLOIDAL STABILITY OF CERAMIC SUSPENSIONS ON NEBULIZATION OF SLURRIES FOR INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
FARINAS, JC ;
MORENO, R ;
MERMET, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (08) :841-849
[5]  
Forzatti P, 1999, CATAL TODAY, V52, P165, DOI 10.1016/S0920-5861(99)00178-9
[6]   MULTIELEMENT ANALYSIS OF ALUMINUM-BASED CERAMIC POWDERS BY INSTRUMENTAL AND RADIOCHEMICAL NEUTRON-ACTIVATION ANALYSIS [J].
FRANEK, M ;
KRIVAN, V .
ANALYTICA CHIMICA ACTA, 1993, 282 (01) :199-207
[7]   Structural characteristics and reactivity properties of highly dispersed Al2O3/SiO2 and V2O5/Al2O3/SiO2 catalysts [J].
Gao, XT ;
Wachs, IE .
JOURNAL OF CATALYSIS, 2000, 192 (01) :18-28
[8]   SLURRY NEBULIZATION INDUCTIVELY-COUPLED PLASMA SPECTROMETRY - THE FUNDAMENTAL PARAMETERS DISCUSSED [J].
GOODALL, P ;
FOULKES, ME ;
EBDON, L .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (13) :1563-1577
[9]   DIRECT INTRODUCTION OF POWDER SAMPLES FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY - EFFECT OF PARTICLE-SIZE ON EMISSION INTENSITY [J].
GUEVREMONT, R ;
DESILVA, KN .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (01) :67-78
[10]  
HARADA Y, 1986, BUNSEKI KAGAKU, V35, P641