A comparison of the I-Gel supraglottic device with endotracheal intubation for bronchoscopic lung volume reduction coil treatment

被引:13
作者
Arevalo-Ludena, Julian [1 ]
Juan Arcas-Bellas, Jose [1 ]
Alvarez-Rementeria, Rafael [1 ]
Flandes, Javier [2 ]
Moris, Laura [1 ]
Munoz Alameda, Luis E. [1 ]
机构
[1] Univ Hosp Fdn Jimenez Diaz, Dept Anesthesiol, Madrid, Spain
[2] Univ Hosp Fdn Jimenez Diaz, Dept Pneumol & Bronchoscopy, Madrid, Spain
关键词
I-gel airway; Laryngeal mask airway; Bronchoscopic coil treatment; LARYNGEAL MASK AIRWAY; OBSTRUCTIVE PULMONARY-DISEASE; ANESTHETIZED PATIENTS; TRACHEAL TUBE; LMA; VENTILATION; MANAGEMENT; I-GEL(TM); EMPHYSEMA;
D O I
10.1016/j.jclinane.2016.02.016
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study objective: To compare the use of the I-gel airway with orotracheal intubation (OTI) for bronchoscopic lung volume reduction (BLVR) coil treatment in patients with severe chronic obstructive pulmonary disease (COPD) with heterogeneous emphysema, since it has been proved that supraglottic airways have lower incidence of postoperative respiratory complaints compared to OTI. Design: A comparative, prospective observational study was designed to assess the use of the I-gel airway compared with the OTI. Setting: Bronchoscopy room at the University Hospital Fundacion Jimenez Diaz, Madrid. Tertiary care center. Patients: Thirty-three procedures were carried out in 22 patients diagnosed with COPD with severe heterogeneous emphysema undergoing BLVR coil treatment under general anaesthesia. Intervention: Seventeen procedures were carried out with I-gel and 16 with endotracheal tube. Airway device choice was left to the attendant anesthesiologist. Measurements: Tidal volume, peak pressure, and the presence of gas leaks were compared. Adverse events during the procedure and within the first 3 hours later were also recorded. Main results: Ventilation parameters obtained showed no significant differences. Mean tidal volume was 466.6 +/- 28.2 mL and 478.7 +/- 34.0 mL (P > .05), mean peak pressure was 17.9 +/- 2.5 cmH(2)O and 19.4 +/- 2.4 cmH(2)O (P > .05) and mean gas leaks was 71 +/- 17.6 mL and 79 +/- 15.5 mL (P > .05) for I-gel group (IgelG) and endotracheal tube group respectively. No serious complications were reported. One case of pneumothorax was reported in the endotracheal tube group, which was resolved with a chest drainage tube without further complications. Conclusion: The I-gel airway ensures appropriate ventilation and makes the use of the flexible fiberoptic bronchoscope quite easy. Therefore, we consider that the I-gel device is an effective and safe alternative to classical OTI for airway management in COPD patients with severe heterogeneous emphysema undergoing BLVR coil treatment. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:137 / 141
页数:5
相关论文
共 22 条
  • [1] [Anonymous], 2012, I GELTM US GUID
  • [2] Comparison of respiratory mechanics between sevoflurane and propofol-remifentanil anesthesia for laparoscopic colectomy
    Bang, Si Ra
    Lee, Sang Eun
    Ahn, Hyun Joo
    Kim, Jie Ae
    Shin, Byung Seop
    Roe, Hee Jin
    Sim, Woo Seog
    [J]. KOREAN JOURNAL OF ANESTHESIOLOGY, 2014, 66 (02) : 131 - 135
  • [3] THE LARYNGEAL MASK - A NEW CONCEPT IN AIRWAY MANAGEMENT
    BRAIN, AIJ
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1983, 55 (08) : 801 - 805
  • [4] THE ADVANTAGES OF THE LMA OVER THE TRACHEAL TUBE OR FACEMASK - A METAANALYSIS
    BRIMACOMBE, J
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (11): : 1017 - 1023
  • [5] Lung volume reduction coil treatment for patients with severe emphysema: a European multicentre trial
    Deslee, Gaetan
    Klooster, Karin
    Hetzel, Martin
    Stanzel, Franz
    Kessler, Romain
    Marquette, Charles-Hugo
    Witt, Christian
    Blaas, Stefan
    Gesierich, Wolfgang
    Herth, Felix J. F.
    Hetzel, Juergen
    van Rikxoort, Eva M.
    Slebos, Dirk-Jan
    [J]. THORAX, 2014, 69 (11) : 980 - 986
  • [6] Idrees A, 2000, J Pak Med Assoc, V50, P333
  • [7] Use of the laryngeal mask airway as an alternative to the tracheal tube during ambulatory anesthesia
    Joshi, GP
    Inagaki, Y
    White, PF
    TaylorKennedy, L
    Wat, LI
    Gevirtz, C
    McCraney, JM
    McCulloch, DA
    [J]. ANESTHESIA AND ANALGESIA, 1997, 85 (03) : 573 - 577
  • [8] The lung volume reduction coil for the treatment of emphysema: a new therapy in development
    Klooster, Karin
    ten Hacken, Nick H. T.
    Slebos, Dirk-Jan
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2014, 11 (05) : 481 - 489
  • [9] The ProSeal™ laryngeal mask airway is an effective alternative to laryngoscope-guided tracheal intubation for gynaecological laparoscopy
    Lim, Y.
    Goel, S.
    Brimacombe, J. R.
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2007, 35 (01) : 52 - 56
  • [10] ANESTHETIC EFFECTS ON VENTILATION IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY-DISEASE
    PIETAK, S
    WEENIG, CS
    HICKEY, RF
    FAIRLEY, HB
    [J]. ANESTHESIOLOGY, 1975, 42 (02) : 160 - 166