Tribocorrosion in Hip Modular Taper Junctions: Load-Triggered Transitions in Electrochemical and Mechanical Behavior

被引:2
作者
Mathew, Mathew T. [1 ]
Patel, Megha [1 ,2 ]
Royhman, Dmitry [1 ]
Runa, Maria [1 ,3 ]
Jacobs, Joshua [1 ]
Wimmer, Markus A. [1 ]
Hallab, Nadim J. [1 ]
机构
[1] Rush Univ, Med Ctr, Dept Orthoped Surg, 1611 West Harrison St, Chicago, IL 60612 USA
[2] Univ Illinois, Med Biotechnol, Dept Biomed Sci, Rockford, IL 61101 USA
[3] Univ Minho, Ctr Mech & Mat Technol CT2M, P-4800058 Guimaraes, Portugal
来源
MODULARITY AND TAPERS IN TOTAL JOINT REPLACEMENT DEVICES | 2015年 / 1591卷
关键词
modularity; fretting corrosion; friction energy; metal-on-metal; FRETTING-CORROSION; CREVICE CORROSION; WEAR BEHAVIOR; METAL; ALLOY; TITANIUM; PRODUCTS; COCRMO; STEEL; JOINT;
D O I
10.1520/STP159120140147
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Modular hip junctions operate in a challenging environment. This includes exposure to cyclic loads, micromotions at the interfaces, and a shifting local chemical environment. The objectives of this study are to identify the tribocorrosion mechanisms in mixed-metal contacts under a simulated joint environment at various axial loads at two pH levels. Fretting-corrosion tests were conducted in a custom-made apparatus, by articulating a square Ti-6Al-4V-alloy rod with two, axially loaded, CoCrMo pins (15 cm(2) exposed surface area) in a flat-on-flat contact system. Bovine calf serum (BCS) solution was used as an electrolyte (electrolyte volume = 70 mL with 30 g/L protein content). A sinusoidal fretting motion, with a displacement amplitude of +/- 50 mu M was applied to the Ti-6Al-4V-alloy rod. To evaluate the effect of load, a range of normal loads (50-800 N) was applied at two different pH levels (pH 3.0 and pH 7.6). We observed variations in electrochemical potential and dissipated friction energy that were both functions of load and pH. Under gross slip conditions, there was an increase in magnitude of potential drop as a function of load until a critical value was reached. This was likely related to the incremental increase in the tribo-activated area. At high load, the fretting zone was in the stick-slip fretting region, where the sliding amplitude was almost zero. Hence, at high load, the reduction in the magnitude of potential drop is caused by a reduced tribo-activated area. In addition, the presence of a tribofilm was observed at high load, possibly offering electrochemical protection to the surface. The data indicate that mechanistic transitions in the fretting-corrosion behavior of modular junctions depend on applied load and pH.
引用
收藏
页码:283 / 302
页数:20
相关论文
共 40 条
  • [1] Electrochemical Behavior of Titanium in Artificial Saliva: Influence of pH
    Abey, Savithri
    Mathew, Mathew T.
    Lee, Damian J.
    Knoernschild, Kent L.
    Wimmer, Markus A.
    Sukotjo, Cortino
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (01) : 3 - 10
  • [2] Metal ion levels in the blood of patients after hip resurfacing: A comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses
    Antoniou, John
    Zukor, David J.
    Mwale, Fackson
    Minarik, William
    Petit, Alain
    Huk, Olga L.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A : 142 - 148
  • [3] High body mass index is associated with increased risk of implant dislocation following primary total hip replacement - 2,106 patients followed for up to 8 years
    Azodi, Omid Sadr
    Adami, Johanna
    Lindstroem, David
    Eriksson, Karl O.
    Wladis, Andreas
    Bellocco, Rino
    [J]. ACTA ORTHOPAEDICA, 2008, 79 (01) : 141 - 147
  • [4] Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study
    Barao, Valentim A. R.
    Mathew, Mathew T.
    Assuncao, Wirley Goncalves
    Yuan, Judy Chia-Chun
    Wimmer, Markus A.
    Sukotjo, Cortino
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (09) : 1055 - 1062
  • [5] Corrosion-wear behaviour of thermal sprayed nanostructured FeCu/WC-Co coatings
    Basak, A. K.
    Matteazzi, P.
    Vardavoulias, M.
    Celis, J. -P.
    [J]. WEAR, 2006, 261 (09) : 1042 - 1050
  • [6] The Epidemiology of Revision Total Hip Arthroplasty in the United States
    Bozic, Kevin J.
    Kurtz, Steven M.
    Lau, Edmund
    Ong, Kevin
    Vail, Thomas P.
    Berry, Daniel J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01) : 128 - 133
  • [7] FRETTING CORROSION IN SALINE AND SERUM
    BROWN, SA
    MERRITT, K
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1981, 15 (04): : 479 - 488
  • [8] INVITRO STUDIES OF FRETTING CORROSION OF ORTHOPEDIC MATERIALS
    BROWN, SA
    HUGHES, PJ
    MERRITT, K
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (04) : 572 - 579
  • [9] CREVICE AND FRETTING CORROSION OF STAINLESS-STEEL PLATES AND SCREWS
    BROWN, SA
    SIMPSON, JP
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1981, 15 (06): : 867 - 878
  • [10] BROWN SA, 1981, ARTIF CELL BLOOD SUB, V9, P57