Magnetic reduced graphene oxide functionalized with β-cyclodextrin as magnetic solid-phase extraction adsorbents for the determination of phytohormones in tomatoes coupled with high performance liquid chromatography

被引:71
|
作者
Li, Na [1 ,2 ,3 ]
Chen, Juan [1 ,2 ]
Shi, Yan-Ping [1 ,2 ]
机构
[1] Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Chem Northwestern Plant Resources, Lanzhou 730000, Peoples R China
[2] Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, Lanzhou 730000, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100039, Peoples R China
关键词
Magnetic reduced graphene oxide; beta-Cyclodextrin; Magnetic solid-phase extraction; Phytohormones; High performance liquid chromatography; TANDEM MASS-SPECTROMETRY; PLANT-GROWTH REGULATORS; SAMPLE PREPARATION; WATER SAMPLES; 1-NAPHTHYLACETIC ACID; HORMONES; MICROEXTRACTION; NANOPARTICLES; RECOGNITION; COMPOSITE;
D O I
10.1016/j.chroma.2016.02.077
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A beta-cyclodextrin (beta-CD) functionalized magnetic reduced graphene oxide composite (Fe3O4/RGO@beta-CD) has been prepared and its application as a selective adsorbent for the determination of the two naphthalene-derived phytohormones (1-naphthalene acetic acid (NAA) and 2-naphthoxyacetic acid (2-NOA)) has been investigated. Magnetic reduced graphene oxide composite (Fe3O4/RGO) was first synthesized via in situ chemical precipitation method and then beta-CD was applied to further functionalize the resultant Fe3O4/RGO composite. The as-prepared Fe3O4/RGO@beta-CD was characterized by Fourier transform infrared spectrometry (FT-IR), X-ray diffraction (XRD) and vibrating sample magnetometer (VSM). Compared with Fe3O4/RGO, the as -prepared Fe3O4/RGO beta-CD showed better molecular selectivity and higher extraction efficiency for NAA and 2-NOA by dint of the size complementarity brought by the introduction of beta-CD. Response surface methodology (RSM), a multivariate experimental design technique, was used to optimize experimental parameters affecting the extraction efficiency in detail. Under the optimal conditions, good performance data was obtained. The calibration curves were linear over the concentration ranging from 2 to 600 ng g(-1) with correlation coefficients (R-2) between 0.9995 and 0.9997 for all the analytes. The limits of detection (LODs) were 0.67 ng g(-1) for both NAA and 2-NOA. The intra- and inter-day relative standard deviations (RSDs) were less than 6.02% and 7.34%, respectively. The recoveries ranged from 91.45% to 95.89%. Taken together, the proposed method was an efficient pretreatment and enrichment procedure and could be successfully applied for selective extraction and determination of naphthalene-derived phytormones in complex matrices. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:24 / 33
页数:10
相关论文
共 50 条
  • [31] Magnetic chitosan functionalized with -cyclodextrin as ultrasound-assisted extraction adsorbents for the removal of methyl orange in wastewater coupled with high-performance liquid chromatography
    Dai, Yunliang
    Row, Kyung Ho
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (17) : 3397 - 3403
  • [32] N-doped carbon nanotubes-reinforced hollow fiber solid-phase microextraction coupled with high performance liquid chromatography for the determination of phytohormones in tomatoes
    Han, Xiao-Fei
    Chen, Juan
    Shi, Yan-Ping
    TALANTA, 2018, 185 : 132 - 140
  • [33] Selective capture and determination of doxycycline in marine sediments by using magnetic imprinting dispersive solid-phase extraction coupled with high performance liquid chromatography
    He, Cheng
    Ma, Jiaxin
    Xu, Huan
    Ge, Changzi
    Lian, Ziru
    MARINE POLLUTION BULLETIN, 2022, 184
  • [34] Determination of six ultraviolet filters in cosmetics by high performance liquid chromatography coupled with solid-phase extraction based on graphene sponge
    Wang Xuemei
    Wang Juan
    Du Tongtong
    Ma Xiaomin
    Lu Xianquan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2018, 36 (03) : 190 - 194
  • [35] A simple magnetic solid-phase extraction method based on magnetite/graphene oxide nanocomposite for pre-concentration and determination of melamine by high-performance liquid chromatography
    Hossein Abdolmohammad-Zadeh
    Abbasali Zamani
    Zahra Shamsi
    Environmental Science and Pollution Research, 2020, 27 : 9826 - 9834
  • [36] A simple magnetic solid-phase extraction method based on magnetite/graphene oxide nanocomposite for pre-concentration and determination of melamine by high-performance liquid chromatography
    Abdolmohammad-Zadeh, Hossein
    Zamani, Abbasali
    Shamsi, Zahra
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (09) : 9826 - 9834
  • [37] Determination of four parabens in cosmetics by high-performance liquid chromatography with magnetic solid-phase and ionic dispersive liquid liquid extraction
    Gao, Xun
    Xu, Kai
    Chi, Miaomiao
    Li, Jiaojiao
    Suo, Lingzhe
    Zhu, Lin
    Chen, Kexin
    Mu, Jingqing
    REVIEWS IN ANALYTICAL CHEMISTRY, 2021, 40 (01) : 161 - 172
  • [38] Liquid-solid extraction coupled with magnetic solid-phase extraction for determination of pyrethroid residues in vegetable samples by ultra fast liquid chromatography
    Jiang, Chunzhu
    Sun, Ying
    Yu, Xi
    Gao, Yan
    Zhang, Lei
    Wang, Yuanpeng
    Zhang, Hanqi
    Song, Daqian
    TALANTA, 2013, 114 : 167 - 175
  • [39] Determination of three hydroxyl polycyclic aromatic hydrocarbons in urine using magnetic solid-phase extraction with magnetic carbon nitride composites coupled with high performance liquid chromatography
    Nian Qixun
    Liu Yuanman
    Sun Bing
    Wang Manman
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2019, 37 (03) : 252 - 258
  • [40] Determination of 11 Phthalate Esters in Beverages by Magnetic Solid-Phase Extraction Combined with High-Performance Liquid Chromatography
    Yin, Shuo
    Yang, Yi
    Yang, Danni
    Li, Yongxin
    Jiang, Yang
    Wu, Ling
    Sun, Chengjun
    JOURNAL OF AOAC INTERNATIONAL, 2019, 102 (05) : 1624 - 1631