Diffusion-Tensor Imaging Versus Digitization in Reconstructing the Masseter Architecture

被引:9
作者
Falcinelli, Cristina [1 ,5 ]
Li, Zhi [2 ]
Lam, Wilfred W. [3 ]
Stanisz, Greg J. [3 ]
Agur, Anne M. [2 ]
Whyne, Cari M. [4 ]
机构
[1] Sunnybrook Res Inst, Orthopaed Biomech Lab, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Fac Med, Div Anat, Musculoskeletal Anat Lab, 1 Kings Coll Circle,Room 1158, Toronto, ON M5S 1A8, Canada
[3] Sunnybrook Res Inst, Phys Sci, Room S6 05 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
[4] Sunnybrook Res Inst, Orthopaed Biomech Lab, Room S6 20 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
[5] Univ Rome, Dept Engn, Campus Biomed,Via Alvaro del Portillo 21, I-00128 Rome, Italy
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2018年 / 140卷 / 11期
基金
加拿大自然科学与工程研究理事会;
关键词
diffusion tensor imaging; 3D muscle modeling; fiber tracking; muscle fiber directionality; magnetic resonance imaging; MUSCLE ARCHITECTURE; SKELETAL-MUSCLE; FIBER TRACTOGRAPHY; ORGANIZATION; VALIDATION; LENGTH;
D O I
10.1115/1.4041541
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Accurate characterization of the craniomaxillofacial (CMF) skeleton using finite element (FE) modeling requires representation of complex geometries, heterogeneous material distributions, and physiological loading. Musculature in CMF FE models are often modeled with simple link elements that do not account for fiber bundles (FBs) and their differential activation. Magnetic resonance (MR) diffusion-tensor imaging (DTI) enables reconstruction of the three-dimensional (3D) FB arrangement within a muscle. However, 3D quantitative validation of DTI-generated FBs is limited. This study compares 3D FB arrangement in terms of pennation angle (PA) and fiber bundle length (FBL) generated through DTI in a human masseter to manual digitization. CT, MR-proton density, and MR-DTI images were acquired from a single cadaveric specimen. Bone and masseter surfaces were reconstructed from CT and MR-proton density images, respectively. PA and FBL were estimated from FBs reconstructed from MR-DTI images using a streamline tracking (STT) algorithm (n = 193) and FBs identified through manual digitization (n = 181) and compared using the Mann-Whitney test. DTI-derived PAs did not differ from the digitized data (p = 0.411), suggesting that MR-DTI can be used to simulate FB orientation and the directionality of transmitted forces. Conversely, a significant difference was observed in FBL (p <0.01) which may have resulted due to the tractography stopping criterion leading to early tract termination and greater length variability. Overall, this study demonstrated that DTI can yield muscle FB orientation data suitable to representative directionality of physiologic muscle loading in patient-specific CMF FE modeling.
引用
收藏
页数:6
相关论文
共 46 条
  • [1] MUSCLE FIBRE SIZE IN NORMAL INFANTS, CHILDREN AND ADOLESCENTS - AUTOPSY STUDY
    AHERNE, W
    AYYAR, DR
    CLARKE, PA
    WALTON, JN
    [J]. JOURNAL OF THE NEUROLOGICAL SCIENCES, 1971, 14 (02) : 171 - +
  • [2] Ahh SE., 2015, PLOS ONE, V10, P1
  • [3] Comparing a diffusion tensor and non-tensor approach to white matter fiber tractography in chronic stroke
    Auriat, A. M.
    Borich, M. R.
    Snow, N. J.
    Wadden, K. P.
    Boyd, L. A.
    [J]. NEUROIMAGE-CLINICAL, 2015, 7 : 771 - 781
  • [4] Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
  • [5] 2-O
  • [6] Probabilistic diffusion tractography with multiple fibre orientations: What can we gain?
    Behrens, T. E. J.
    Berg, H. Johansen
    Jbabdi, S.
    Rushworth, M. F. S.
    Woolrich, M. W.
    [J]. NEUROIMAGE, 2007, 34 (01) : 144 - 155
  • [7] Image-based musculoskeletal modeling: Applications, advances, and future opportunities
    Blemker, Silvia S.
    Asakawa, Deanna S.
    Gold, Garry E.
    Delp, Scott L.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (02) : 441 - 451
  • [8] How does passive lengthening change the architecture of the human medial gastrocnemius muscle?
    Bolsterlee, Bart
    D'Souza, Arkiev
    Gandevia, Simon C.
    Herbert, Robert D.
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2017, 122 (04) : 727 - 738
  • [9] Comparison of measurements of medial gastrocnemius architectural parameters from ultrasound and diffusion tensor images
    Bolsterlee, Bart
    Veeger, H. E. J.
    van der Helm, Frans C. T.
    Gandevia, Simon C.
    Herbert, Robert D.
    [J]. JOURNAL OF BIOMECHANICS, 2015, 48 (06) : 1133 - 1140
  • [10] General organization of the human intra-masseteric aponeuroses: changes with ageing
    Brunel, G
    El Haddioui, A
    Bravetti, P
    Zouaoui, A
    Gaudy, JF
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2003, 25 (3-4) : 270 - 283