A New Redox Mediator (Cupric-Neocuproine Complex)-Modified Pencil Graphite Electrode for the Electrocatalytic Oxidation of H2O2: A Flow Injection Amperometric Sensor

被引:18
作者
Emir, Gamze [1 ]
Dilgin, Yusuf [1 ]
Apak, Resat [2 ]
机构
[1] Canakkale Onsekiz Mart Univ, Dept Chem, Fac Sci & Arts, TR-17100 Canakkale, Turkey
[2] Istanbul Univ Cerrahpasa, Dept Chem, Fac Engn, TR-34320 Istanbul, Turkey
关键词
hydrogen peroxide; cupric-neocuproine complex; nafion; pencil graphite electrode; flow injection analysis; ANTIOXIDANT CAPACITY CUPRAC; MWCNT MODIFIED ELECTRODE; REDUCED GRAPHENE OXIDE; HYDROGEN-PEROXIDE; ELECTROCHEMICAL DETERMINATION; COMPOSITE-MATERIAL; SCAVENGING ASSAY; REDUCTION; PHENOLICS; COMPLEX;
D O I
10.1002/celc.201901765
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This paper introduces the cupric-neocuproine complex ([Cu(Nc)(2)](2+)) as a new redox mediator for the electrocatalytic oxidation of H2O2. For this purpose, [Cu(Nc)(2)](2+) was modified onto a disposable pencil graphite electrode (PGE) surface by using Nafion (Nf) as a cation-exchange membrane for the effective adsorption of complex. The modified electrode was prepared by immersing Nf-adsorbed PGE into [Cu(Nc)(2)](2+) complex solution (0.40 mM of Cu2+ and 0.80 mM of Nc prepared at pH 4.76 in 0.10 M acetate buffer). SEM images and EDX spectra of electrodes were presented for the elucidation of their surface morphologies. Cyclic voltammetric results showed that H2O2 was electrocatalytically oxidized at [Cu(Nc)(2)](2+)/Nf/PGE, because both the increase in current and the potential shift to a more negative direction were observed for oxidation of H2O2 at [Cu(Nc)(2)](2+)/Nf/PGE in comparison to bare PGE. Then, the electrocatalytic activity of [Cu(Nc)(2)](2+)/Nf/PGE toward H2O2 oxidation was utilized for amperometric determination of H2O2 in flow injection analysis (FIA) system. Flow injection (FI) amperometric studies showed two linear calibration ranges (1.0-1000.0 mu M (R-2=0.9958) and 1000.0-10000.0 mu M (R-2=0.9902) with a detection limit of 0.4 mu M H2O2 which is considered good for electroanalytical determinations, especially for electrocatalytic oxidation. To test the applicability of the developed FI amperometric hydrogen peroxide sensor, H2O2 contents of some relevant samples were determined.
引用
收藏
页码:649 / 658
页数:10
相关论文
共 50 条
  • [31] MWCNT-chitosan composite chemically modified electrode as an electrochemical detector for highly Selective flow injection analysis of H2O2
    Gayathri, Prakasam
    Kumar, Annamalai Senthil
    [J]. JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2015, 92 (04) : 485 - 488
  • [32] A novel non-enzymatic H2O2 sensor using ZnMn2O4 microspheres modified glassy carbon electrode
    Li, Yuanyuan
    Tang, Li
    Deng, Dongmei
    Ye, Jinhong
    Wu, Zhenyu
    Wang, Jinhua
    Luo, Liqiang
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2019, 179 : 293 - 298
  • [33] Electrocatalytic oxidation of NADH in flow analysis by graphite electrode modified with 2,6-dichlorophenolindophenol salts
    Florou, AB
    Prodromidis, MI
    Karayannis, MI
    Tzouwara-Karayanni, SM
    [J]. ELECTROANALYSIS, 1998, 10 (18) : 1261 - 1268
  • [34] Preparation and characterization of a poly-o-phenylenediamine film modified glassy carbon electrode as a H2O2 sensor
    Zhai, Wenying
    Tian, Xiuying
    Yan, Yun
    Xu, Yuehua
    Zhao, Yuechun
    Liu, Youqin
    [J]. CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 2013, 91 (11): : 1077 - 1084
  • [35] Nanostructured Metal Organic Framework Modified Glassy Carbon Electrode as a High Efficient Non-Enzymatic Amperometric Sensor for Electrochemical Detection of H2O2
    Naseri, Maryam
    Fotouhi, Lida
    Ehsani, Ali
    [J]. JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2018, 9 (01) : 28 - 36
  • [36] Amperometric and Impedimetric H2O2 Biosensor Based on Horseradish Peroxidase Covalently Immobilized at Ruthenium Oxide Nanoparticles Modified Electrode
    Periasamy, Arun Prakash
    Ting, Shan Wei
    Chen, Shen-Ming
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (07): : 2688 - 2709
  • [37] CARBON NANOTUBES-GRAPHITE PASTE ELECTRODE MODIFIED WITH Cu(II)-EXCHANGED ZEOLITE FOR H2O2 DETECTION
    Gligor, Delia
    Varodi, Codruta
    Maicaneanu, Andrada
    Muresan, Liana Maria
    [J]. STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2010, 55 (02): : 293 - 302
  • [38] An electrochemical sensor based on multiferroic NdFeO3 particles modified electrode for the detection of H2O2
    Rajaitha, P. Mary
    Hajra, Sugato
    Padhan, Aneeta Manjari
    Panda, Swati
    Sahu, Manisha
    Kim, Hoe Joon
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2022, 915
  • [39] A novel nonenzymatic H2O2 sensor based on cobalt hexacyanoferrate nanoparticles and graphene composite modified electrode
    Yang, Suling
    Li, Gang
    Wang, Guifang
    Zhao, Junhong
    Hu, Meifang
    Qu, Lingbo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 593 - 599
  • [40] Electrocatalytic Lignin Valorization via Enhanced H2O2 Generation Using a MWNCT-Modified Gas Diffusion Electrode
    Wang, Lei
    Liu, Shuangyan
    Meng, Jinyou
    Song, Meng
    Jiao, Mingli
    Jiang, Haomin
    Chen, Yongmei
    [J]. CHEMPLUSCHEM, 2025,