hydrogen peroxide; cupric-neocuproine complex; nafion; pencil graphite electrode; flow injection analysis; ANTIOXIDANT CAPACITY CUPRAC; MWCNT MODIFIED ELECTRODE; REDUCED GRAPHENE OXIDE; HYDROGEN-PEROXIDE; ELECTROCHEMICAL DETERMINATION; COMPOSITE-MATERIAL; SCAVENGING ASSAY; REDUCTION; PHENOLICS; COMPLEX;
D O I
10.1002/celc.201901765
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This paper introduces the cupric-neocuproine complex ([Cu(Nc)(2)](2+)) as a new redox mediator for the electrocatalytic oxidation of H2O2. For this purpose, [Cu(Nc)(2)](2+) was modified onto a disposable pencil graphite electrode (PGE) surface by using Nafion (Nf) as a cation-exchange membrane for the effective adsorption of complex. The modified electrode was prepared by immersing Nf-adsorbed PGE into [Cu(Nc)(2)](2+) complex solution (0.40 mM of Cu2+ and 0.80 mM of Nc prepared at pH 4.76 in 0.10 M acetate buffer). SEM images and EDX spectra of electrodes were presented for the elucidation of their surface morphologies. Cyclic voltammetric results showed that H2O2 was electrocatalytically oxidized at [Cu(Nc)(2)](2+)/Nf/PGE, because both the increase in current and the potential shift to a more negative direction were observed for oxidation of H2O2 at [Cu(Nc)(2)](2+)/Nf/PGE in comparison to bare PGE. Then, the electrocatalytic activity of [Cu(Nc)(2)](2+)/Nf/PGE toward H2O2 oxidation was utilized for amperometric determination of H2O2 in flow injection analysis (FIA) system. Flow injection (FI) amperometric studies showed two linear calibration ranges (1.0-1000.0 mu M (R-2=0.9958) and 1000.0-10000.0 mu M (R-2=0.9902) with a detection limit of 0.4 mu M H2O2 which is considered good for electroanalytical determinations, especially for electrocatalytic oxidation. To test the applicability of the developed FI amperometric hydrogen peroxide sensor, H2O2 contents of some relevant samples were determined.
引用
收藏
页码:649 / 658
页数:10
相关论文
共 50 条
[21]   Fabrication of an electrochemical H2O2 biosensor based on immobilization of hemoglobin nanoparticles onto pencil graphite electrode [J].
Narwal, Vinay ;
Deswal, Ritu ;
Pundir, C. S. .
PROCESS BIOCHEMISTRY, 2018, 71 :61-68
[22]   Non-enzymatic amperometric sensing of hydrogen peroxide at a CuS modified electrode for the determination of urine H2O2 [J].
Dutta, Amit Kumar ;
Das, Sudipto ;
Samanta, Partha Kumar ;
Roy, Shounak ;
Adhikary, Bibhutosh ;
Biswas, Papu .
ELECTROCHIMICA ACTA, 2014, 144 :282-287
[23]   Direct Electrochemistry of Catalase Immobilized at Electrochemically Reduced Graphene Oxide Modified Electrode for Amperometric H2O2 Biosensor [J].
Ting, Shan Wei ;
Periasamy, Arun Prakash ;
Chen, Shen-Ming ;
Saraswathi, R. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (10) :4438-4453
[24]   Electrocatalytic reduction of O2 and H2O2 at the glass carbon electrode modified with microperoxidase-11 [J].
Yang, H ;
Huang, ZH ;
Jiang, HJ ;
Zhou, JH ;
Lu, TH ;
Wang, FB ;
Xing, W .
ACTA PHYSICO-CHIMICA SINICA, 2000, 16 (06) :527-532
[25]   The fabrication of a new modified pencil graphite electrode for the electrocatalytic reduction of 2-nitrophenol in water samples [J].
Baysal, Gulsen ;
Uzun, Demet ;
Hasdemir, Erdogan .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 860
[26]   Electrochemical investigation of a new Cu-MOF and its electrocatalytic activity towards H2O2 oxidation in alkaline solution [J].
Zhang, Chengyan ;
Wang, Mingyan ;
Liu, Lin ;
Yang, Xujie ;
Xu, Xingyou .
ELECTROCHEMISTRY COMMUNICATIONS, 2013, 33 :131-134
[27]   π-Self-Assembly of a Coronene on Carbon Nanomaterial-Modified Electrode and Its Symmetrical Redox and H2O2 Electrocatalytic Reduction Functionalities [J].
Nisha, Sivakumar ;
Kumar, Annamalai Senthil .
ACS OMEGA, 2020, 5 (20) :11817-11828
[28]   Simultaneous detection of NADH and H2O2 using flow injection analysis based on a bifunctional poly(thionine)-modified electrode [J].
Baskar, Selvaraj ;
Chang, Jen-Lin ;
Zen, Jyh-Myng .
BIOSENSORS & BIOELECTRONICS, 2012, 33 (01) :95-99
[29]   Chemiluminescent flow sensor for H2O2 based on the decomposition of H2O2 catalyzed by cobalt(II)-ethanolamine complex immobilized on resin [J].
Hanaoka, S ;
Lin, JM ;
Yamada, M .
ANALYTICA CHIMICA ACTA, 2001, 426 (01) :57-64
[30]   Electrocatalytic oxidation and reduction of H2O2 on vertically aligned Co3O4 nanowalls electrode: Toward H2O2 detection [J].
Jia, Wenzhao ;
Guo, Min ;
Zheng, Zhe ;
Yu, Ting ;
Rodriguez, Edgar G. ;
Wang, Ying ;
Lei, Yu. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 625 (01) :27-32