A New Redox Mediator (Cupric-Neocuproine Complex)-Modified Pencil Graphite Electrode for the Electrocatalytic Oxidation of H2O2: A Flow Injection Amperometric Sensor

被引:18
|
作者
Emir, Gamze [1 ]
Dilgin, Yusuf [1 ]
Apak, Resat [2 ]
机构
[1] Canakkale Onsekiz Mart Univ, Dept Chem, Fac Sci & Arts, TR-17100 Canakkale, Turkey
[2] Istanbul Univ Cerrahpasa, Dept Chem, Fac Engn, TR-34320 Istanbul, Turkey
关键词
hydrogen peroxide; cupric-neocuproine complex; nafion; pencil graphite electrode; flow injection analysis; ANTIOXIDANT CAPACITY CUPRAC; MWCNT MODIFIED ELECTRODE; REDUCED GRAPHENE OXIDE; HYDROGEN-PEROXIDE; ELECTROCHEMICAL DETERMINATION; COMPOSITE-MATERIAL; SCAVENGING ASSAY; REDUCTION; PHENOLICS; COMPLEX;
D O I
10.1002/celc.201901765
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This paper introduces the cupric-neocuproine complex ([Cu(Nc)(2)](2+)) as a new redox mediator for the electrocatalytic oxidation of H2O2. For this purpose, [Cu(Nc)(2)](2+) was modified onto a disposable pencil graphite electrode (PGE) surface by using Nafion (Nf) as a cation-exchange membrane for the effective adsorption of complex. The modified electrode was prepared by immersing Nf-adsorbed PGE into [Cu(Nc)(2)](2+) complex solution (0.40 mM of Cu2+ and 0.80 mM of Nc prepared at pH 4.76 in 0.10 M acetate buffer). SEM images and EDX spectra of electrodes were presented for the elucidation of their surface morphologies. Cyclic voltammetric results showed that H2O2 was electrocatalytically oxidized at [Cu(Nc)(2)](2+)/Nf/PGE, because both the increase in current and the potential shift to a more negative direction were observed for oxidation of H2O2 at [Cu(Nc)(2)](2+)/Nf/PGE in comparison to bare PGE. Then, the electrocatalytic activity of [Cu(Nc)(2)](2+)/Nf/PGE toward H2O2 oxidation was utilized for amperometric determination of H2O2 in flow injection analysis (FIA) system. Flow injection (FI) amperometric studies showed two linear calibration ranges (1.0-1000.0 mu M (R-2=0.9958) and 1000.0-10000.0 mu M (R-2=0.9902) with a detection limit of 0.4 mu M H2O2 which is considered good for electroanalytical determinations, especially for electrocatalytic oxidation. To test the applicability of the developed FI amperometric hydrogen peroxide sensor, H2O2 contents of some relevant samples were determined.
引用
收藏
页码:649 / 658
页数:10
相关论文
共 50 条
  • [11] Glassy carbon electrode modified with hemin and new melamine compounds for H2O2 amperometric detection
    Deac, Aglaia Raluca
    Morar, Cristina
    Turdean, Graziella Liana
    Darabantu, Mircea
    Gal, Emese
    Bende, Attila
    Muresan, Liana Maria
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2016, 20 (11) : 3071 - 3081
  • [12] NEW METHOD FOR ANTIOXIDANT ACTIVITY EVALUATION USING A H2O2 AMPEROMETRIC SENSOR
    Varvari, Lidia
    Popescu, Ionel Catalin
    REVUE ROUMAINE DE CHIMIE, 2010, 55 (11-12) : 851 - +
  • [13] Electrocatalytic oxidation and flow injection analysis of formaldehyde at binary metal oxides (Co3O4-NiO and CuO-Co3O4) modified pencil graphite electrodes
    Emir, Gamze
    Karakaya, Serkan
    Ayaz, Selen
    Dilgin, Didem Giray
    Dilgin, Yusuf
    MONATSHEFTE FUR CHEMIE, 2021, 152 (12): : 1491 - 1503
  • [14] ELECTROCHEMICAL BEHAVIOR OF THE HEMIN MODIFIED GRAPHITE ELECTRODE FOR H2O2 DETECTION
    Mares, Georgeta Maria
    Turdean, Graziella Liana
    Popescu, Ionel Catalin
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2013, 58 (02): : 105 - 114
  • [15] INFLUENCE OF GRAPHITE POWDER, ADDITIVES AND ENZYME IMMOBILIZATION PROCEDURES ON A MEDIATORLESS HRP-MODIFIED CARBON-PASTE ELECTRODE FOR AMPEROMETRIC FLOW-INJECTION DETECTION OF H2O2
    POPESCU, IC
    ZETTERBERG, G
    GORTON, L
    BIOSENSORS & BIOELECTRONICS, 1995, 10 (05) : 443 - 461
  • [16] An electrochemical sensor for H2O2 based on a new Co-metal-organic framework modified electrode
    Yang, Lizi
    Xu, Cailing
    Ye, Weichun
    Liu, Weisheng
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 215 : 489 - 496
  • [17] Minimization of Interferences in Flow Injection Amperometric Glucose Biosensor Based on Oxidation of Enzymatically-produced H2O2
    Karakaya, Serkan
    Dilgin, Yusuf
    ELECTROANALYSIS, 2019, 31 (07) : 1373 - 1380
  • [18] A novel non-enzymatic amperometric H2O2 sensor based on screen-printed electrode modified with reduced graphene oxide, polyneutralred and gold nanoparticles
    Kamac, Melike Bilgi
    Onat, Eda Kiymaz
    Yilmaz, Merve
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2020, 100 (04) : 408 - 418
  • [19] Electrocatalytic determination of H2O2 on the electrode modified by LBL assembly of polyoxometalates via zirconium ion glue
    Pourbeyram, S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 192 : 105 - 110
  • [20] Non-enzymatic amperometric sensing of hydrogen peroxide at a CuS modified electrode for the determination of urine H2O2
    Dutta, Amit Kumar
    Das, Sudipto
    Samanta, Partha Kumar
    Roy, Shounak
    Adhikary, Bibhutosh
    Biswas, Papu
    ELECTROCHIMICA ACTA, 2014, 144 : 282 - 287