A New Redox Mediator (Cupric-Neocuproine Complex)-Modified Pencil Graphite Electrode for the Electrocatalytic Oxidation of H2O2: A Flow Injection Amperometric Sensor

被引:18
|
作者
Emir, Gamze [1 ]
Dilgin, Yusuf [1 ]
Apak, Resat [2 ]
机构
[1] Canakkale Onsekiz Mart Univ, Dept Chem, Fac Sci & Arts, TR-17100 Canakkale, Turkey
[2] Istanbul Univ Cerrahpasa, Dept Chem, Fac Engn, TR-34320 Istanbul, Turkey
关键词
hydrogen peroxide; cupric-neocuproine complex; nafion; pencil graphite electrode; flow injection analysis; ANTIOXIDANT CAPACITY CUPRAC; MWCNT MODIFIED ELECTRODE; REDUCED GRAPHENE OXIDE; HYDROGEN-PEROXIDE; ELECTROCHEMICAL DETERMINATION; COMPOSITE-MATERIAL; SCAVENGING ASSAY; REDUCTION; PHENOLICS; COMPLEX;
D O I
10.1002/celc.201901765
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This paper introduces the cupric-neocuproine complex ([Cu(Nc)(2)](2+)) as a new redox mediator for the electrocatalytic oxidation of H2O2. For this purpose, [Cu(Nc)(2)](2+) was modified onto a disposable pencil graphite electrode (PGE) surface by using Nafion (Nf) as a cation-exchange membrane for the effective adsorption of complex. The modified electrode was prepared by immersing Nf-adsorbed PGE into [Cu(Nc)(2)](2+) complex solution (0.40 mM of Cu2+ and 0.80 mM of Nc prepared at pH 4.76 in 0.10 M acetate buffer). SEM images and EDX spectra of electrodes were presented for the elucidation of their surface morphologies. Cyclic voltammetric results showed that H2O2 was electrocatalytically oxidized at [Cu(Nc)(2)](2+)/Nf/PGE, because both the increase in current and the potential shift to a more negative direction were observed for oxidation of H2O2 at [Cu(Nc)(2)](2+)/Nf/PGE in comparison to bare PGE. Then, the electrocatalytic activity of [Cu(Nc)(2)](2+)/Nf/PGE toward H2O2 oxidation was utilized for amperometric determination of H2O2 in flow injection analysis (FIA) system. Flow injection (FI) amperometric studies showed two linear calibration ranges (1.0-1000.0 mu M (R-2=0.9958) and 1000.0-10000.0 mu M (R-2=0.9902) with a detection limit of 0.4 mu M H2O2 which is considered good for electroanalytical determinations, especially for electrocatalytic oxidation. To test the applicability of the developed FI amperometric hydrogen peroxide sensor, H2O2 contents of some relevant samples were determined.
引用
收藏
页码:649 / 658
页数:10
相关论文
共 50 条
  • [1] Flow Injection Amperometric Analysis of H2O2 at Platinum Nanoparticles Modified Pencil Graphite Electrode
    Karakaya, Serkan
    Dilgin, Yusuf
    ELECTROANALYSIS, 2017, 29 (06) : 1626 - 1634
  • [2] Flow injection amperometric determination of hydrazine at a cupric-neocuproine complex/anionic surfactant modified disposable electrode
    Ayaz, Selen
    Dilgin, Yusuf
    Apak, Resat
    MICROCHEMICAL JOURNAL, 2020, 159
  • [3] A novel flow injection amperometric method for sensitive determination of total antioxidant capacity at cupric-neocuproine complex modified MWCNT glassy carbon electrode
    Selen Ayaz
    Ayşem Üzer
    Yusuf Dilgin
    Reşat Apak
    Microchimica Acta, 2022, 189
  • [4] A novel flow injection amperometric method for sensitive determination of total antioxidant capacity at cupric-neocuproine complex modified MWCNT glassy carbon electrode
    Ayaz, Selen
    Uzer, Aysem
    Dilgin, Yusuf
    Apak, Resat
    MICROCHIMICA ACTA, 2022, 189 (04)
  • [5] Flow injection amperometric determination of hydrazine based on its electrocatalytic oxidation at pyrocatechol violet modified pencil graphite electrode
    Ayaz, Selen
    Dilgin, Yusuf
    ELECTROCHIMICA ACTA, 2017, 258 : 1086 - 1095
  • [6] Amperometric sensor for gaseous H2O2 based on copper redox mediator incorporated electrolyte
    Klun, Ursa
    Zorko, David
    Stojanov, Leon
    Mirceski, Valentin
    Jovanovski, Vasko
    SENSORS AND ACTUATORS REPORTS, 2023, 5
  • [7] Electrocatalytic oxidation of H2O2 at an oxycobalt film modified glassy carbon electrode for fermentation monitoring
    Khoo, SB
    Yap, MGS
    Huang, YL
    Guo, SX
    ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) : 133 - 142
  • [8] Electrocatalytic H2O2 amperometric detection using gold nanotube electrode ensembles
    Delvaux, M
    Walcarius, A
    Demoustier-Champagne, S
    ANALYTICA CHIMICA ACTA, 2004, 525 (02) : 221 - 230
  • [9] An Enzyme-free H2O2 Sensor Based on Poly(2-Aminophenylbenzimidazole)/Gold Nanoparticles Coated Pencil Graphite Electrode
    Teker, Mine Sen
    Karaca, Erhan
    Pekmez, Nuran Ozcicek
    Tamer, Ugur
    Pekmez, Kadir
    ELECTROANALYSIS, 2019, 31 (01) : 75 - 82
  • [10] A Novel H2O2 Amperometric Sensor based on Prussian Blue/Palladium Nanoparticles/Graphene Oxide Nanocomposite Modified Electrode
    Ahour, Fatemeh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (06): : 812 - 829