Safety and Efficacy of Leadless Pacemakers: A Systematic Review and Meta-Analysis

被引:56
作者
Ngo, Linh [1 ,2 ,3 ]
Nour, Daniel [2 ]
Denman, Russell A. [2 ]
Walters, Tomos E. [1 ,4 ]
Haqqani, Haris M. [1 ,2 ]
Woodman, Richard J. [5 ]
Ranasinghe, Isuru [1 ,2 ]
机构
[1] Univ Queensland, Sch Clin Med, Brisbane, Qld, Australia
[2] Prince Charles Hosp, Dept Cardiol, Brisbane, Qld, Australia
[3] E Hosp, Cardiovasc Ctr, Hanoi, Vietnam
[4] St Vincents Private Hosp Northside, Brisbane, Qld, Australia
[5] Flinders Univ S Australia, Flinders Ctr Epidemiol & Biostat, Adelaide, SA, Australia
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2021年 / 10卷 / 13期
关键词
efficacy; leadless pacemaker; meta-analysis; safety; systematic review; TRICUSPID REGURGITATION; CARDIAC-PACEMAKER; IMPLANTATION; PERFORMANCE; COMPLICATIONS; EXPERIENCE;
D O I
10.1161/JAHA.120.019212
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Leadless pacemaker is a novel technology, and evidence supporting its use is uncertain. We performed a systematic review and meta-analysis to examine the safety and efficacy of leadless pacemakers implanted in the right ventricle. Methods and Results We searched PubMed and Embase for studies published before June 6, 2020. The primary safety outcome was major complications, whereas the primary efficacy end point was acceptable pacing capture threshold (<= 2 V). Pooled estimates were calculated using the Freedman-Tukey double arcsine transformation. Of 1281 records screened, we identified 36 observational studies of Nanostim and Micra leadless pacemakers, with most (69.4%) reporting outcomes for the Micra. For Micra, the pooled incidence of complications at 90 days (n=1608) was 0.46% (95% CI, 0.08%-1.05%) and at 1 year (n=3194) was 1.77% (95% CI, 0.76%-3.07%). In 5 studies with up to 1-year follow-up, Micra was associated with 51% lower odds of complications compared with transvenous pacemakers (3.30% versus 7.43%; odds ratio [OR], 0.49; 95% CI, 0.34-0.70). At 1 year, 98.96% (95% CI, 97.26%-99.94%) of 1376 patients implanted with Micra had good pacing capture thresholds. For Nanostim, the reported complication incidence ranged from 6.06% to 23.54% at 90 days and 5.33% to 6.67% at 1 year, with 90% to 100% having good pacing capture thresholds at 1 year (pooled result not estimated because of the low number of studies). Conclusions Most studies report outcomes for the Micra, which is associated with a low risk of complications and good electrical performance up to 1-year after implantation. Further data from randomized controlled trials are needed to support the widespread adoption of these devices in clinical practice.
引用
收藏
页数:22
相关论文
共 56 条
[1]   Tricuspid Regurgitation and Implantable Devices [J].
Al-Bawardy, Rasha ;
Krishnaswamy, Amar ;
Rajeswaran, Jeevanantham ;
Bhargava, Mandeep ;
Wazni, Oussama ;
Wilkoff, Bruce ;
Tuzcu, Emin Murat ;
Martin, David ;
Thomas, James ;
Blackstone, Eugene ;
Kapadia, Samir .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (02) :259-266
[2]  
[Anonymous], 2021, J AM HEART ASSOC, V10
[3]   Impact of Leadless Pacemaker Therapy on Cardiac and Atrioventricular Valve Function Through 12 Months of Follow-Up [J].
Beurskens, Niek E. G. ;
Tjong, Fleur V. Y. ;
de Bruin-Bon, Rianne N. A. ;
Dasselaar, Kosse J. ;
Kuijt, Wichert J. ;
Wilde, Arthur A. M. ;
Knops, Reinoud E. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (05)
[4]   Feasibility and long-term effectiveness of a non-apical Micra pacemaker implantation in a referral centre for lead extraction [J].
Bongiorni, Maria Grazia ;
Della Tommasina, Veronica ;
Barletta, Valentina ;
Di Cori, Andrea ;
Rogani, Sara ;
Viani, Stefano ;
Segreti, Luca ;
Paperini, Luca ;
Soldati, Ezio ;
De Lucia, Raffaele ;
Zucchelli, Giulio .
EUROPACE, 2019, 21 (01) :114-120
[5]   Quality of life of patients undergoing conventional vs leadless pacemaker implantation: A multicenter observational study [J].
Cabanas-Grandio, Pilar ;
Garcia Campo, Enrique ;
Bisbal, Felipe ;
Garcia-Seara, Javier ;
Pachon, Marta ;
Juan-Salvadores, Pablo ;
Paredes, Emilio ;
Molinero, Asier ;
Martinez-Sande, Jose Luis ;
Arias, Miguel Angel ;
Iniguez Romo, Andres .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (01) :330-336
[6]   Comparative study of acute and mid-term complications with leadless and transvenous cardiac pacemakers [J].
Cantillon, Daniel J. ;
Dukkipati, Srinivas R. ;
Ip, John H. ;
Exner, Derek V. ;
Niazi, Imran K. ;
Banker, Rajesh S. ;
Rashtian, Mayer ;
Plunkitt, Kenneth ;
Tomassoni, Gery F. ;
Nabutovsky, Yelena ;
Davis, Kevin J. ;
Reddy, Vivek Y. .
HEART RHYTHM, 2018, 15 (07) :1023-1030
[7]  
Cantillon Daniel J, 2017, JACC Clin Electrophysiol, V3, P1296, DOI 10.1016/j.jacep.2017.05.007
[8]   Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation [J].
Chang, James D. ;
Manning, Warren J. ;
Ebrille, Elisa ;
Zimetbaum, Peter J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (18) :2331-2341
[9]   Accelerometer-based atrioventricular synchronous pacing with a ventricular leadless pacemaker: Results from the Micra atrioventricular feasibility studies [J].
Chinitz, Larry ;
Ritter, Philippe ;
Khelae, Surinder Kaur ;
Iacopino, Saverio ;
Garweg, Christophe ;
Grazia-Bongiorni, Maria ;
Neuzil, Petr ;
Johansen, Jens Brock ;
Mont, Lluis ;
Gonzalez, Efrain ;
Sagi, Venkata ;
Duray, Gabor Z. ;
Clementy, Nicolas ;
Sheldon, Todd ;
Splett, Vincent ;
Stromberg, Kurt ;
Wood, Nicole ;
Steinwender, Clemens .
HEART RHYTHM, 2018, 15 (09) :1363-1371
[10]   Transcatheter leadless cardiac pacing The new alternative solution [J].
Da Costa, Antoine ;
Axiotis, Amandine ;
Romeyer-Bouchard, Cecile ;
Abdellaoui, Loucif ;
Afif, Zahi ;
Guichard, Jean Baptiste ;
Gerbay, Antoine ;
Isaaz, Karl .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 227 :122-126