Lumen Apposing Metal Stents (LAMSs) for Drainage of Pancreatic and Gallbladder Collections: A Meta-analysis

被引:27
|
作者
Han, Dennis [1 ]
Inamdar, Sumant [1 ]
Lee, Calvin W. [1 ]
Miller, Larry S. [1 ]
Trindade, Arvind J. [1 ]
Sejpal, Divyesh V. [1 ]
机构
[1] North Shore Univ Hosp, Hofstra Northwell Sch Med, Northwell Hlth Syst, Dept Med,Div Gastroenterol, Manhasset, NY USA
关键词
lumen apposing metal stents; pancreatic fluid collections; pancreatic pseudocyst; walled-off pancreatic necrosis; gallbladder drainage; acute cholecystitis; ULTRASOUND-GUIDED PLACEMENT; WALLED-OFF NECROSIS; FLUID COLLECTIONS; PERCUTANEOUS CHOLECYSTOSTOMY; ACUTE CHOLECYSTITIS; ENDOSCOPIC NECROSECTOMY; PSEUDOCYST; MANAGEMENT; EFFICACY; THERAPY;
D O I
10.1097/MCG.0000000000000934
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims:Endoscopic ultrasound-guided transmural drainage using lumen apposing metal stents (LAMSs) is becoming a popular and promising therapeutic approach for drainage of intra-abdominal fluid collections. There has been an increasing number of studies evaluating LAMS for drainage of pancreatic pseudocysts (PP), walled-off pancreatic necrosis (WOPN), and gallbladder (GB) drainage. The aim of this meta-analysis is to analyze the literature to date regarding the clinical success, technical success, and adverse events of LAMS in treatment of pancreatic fluid collections and GB drainage.Methods:A comprehensive search of multiple literature databases through November 2016 was performed. Human studies with at least 10 subjects that examined the clinical success, technical success, and adverse events of LAMS in treating PP, WOPN, and GB drainage were included.Results:A total of 993 patients (608WOPN; 204PP; 181GB drainage) underwent drainage from 20 trials. For drainage of WOPN, the pooled technical success was 98.9% [95% confidence interval (CI): 98.2% to 99.7%] and clinical success was 90% (95% CI: 87% to 93%) ((2)=0.001). For drainage of PP, the pooled technical success was 97% (95% CI: 95% to 99%) and clinical success was 98% (95% CI: 96% to 100%), ((2)=0.001). For GB drainage, the pooled technical success was 95% (95% CI: 91% to 99%) and clinical success was 93% (95% CI: 90% to 97%), ((2)=0.001). Total adverse events occurred in 11% of patients with higher complication rates observed in GB drainage. There was no evidence of publication bias in this meta-analysis.Conclusions:Endoscopic ultrasound-guided transmural drainage using LAMS is becoming a widely accepted therapeutic approach for the treatment of PP, WOPN, and GB drainage with high clinical and technical success rates and acceptable adverse events. Further prospective randomized trials reporting long-term clinical efficacy and cost-effectiveness are needed to validate LAMS as a therapeutic modality for pancreatic and GB collections.
引用
收藏
页码:835 / 844
页数:10
相关论文
共 50 条
  • [31] Head-to-head comparison between endoscopic ultrasound guided lumen apposing metal stent and plastic stents for the treatment of pancreatic fluid collections: A systematic review and meta-analysis
    Guzman-Calderon, Edson
    Chacaltana, Alfonso
    Diaz, Ramiro
    Li, Bruno
    Martinez-Moreno, Belen
    Aparicio, Jose Ramon
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2022, 29 (02) : 198 - 211
  • [32] Timing of lumen-apposing metal stents removal in pancreatic fluid collections: Could we go beyond?
    Stigliano, S.
    Marocchi, G.
    Baldaro, F.
    Neri, B.
    Blanco, G. Del Vecchio
    Troncone, E.
    Di Matteo, F. M.
    PANCREATOLOGY, 2024, 24 (08) : 1252 - 1256
  • [33] Lumen-apposing metal stents in management of pancreatic fluid collections: The nobody's land of removal timing
    De Angelis, Claudio Giovanni
    Venezia, Ludovica
    Valdivia, Pablo Cortegoso
    Rizza, Stefano
    Bruno, Mauro
    Pellicano, Rinaldo
    SAUDI JOURNAL OF GASTROENTEROLOGY, 2019, 25 (06) : 335 - 340
  • [34] Effect of Plastic Stents Following Lumen-Apposing Metal Stent Placement on Recurrence of Pancreatic Fluid Collections in Disconnected Pancreatic Duct Syndrome: A Systematic Review and Meta-Analysis
    Liu, Jiawen
    Wei, Zhengjie
    Huang, Qing
    Yang, Shizhong
    Fang, Yanbin
    Ren, Yutang
    Jiang, Xuan
    Jiang, Bo
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2024, 34 (04) : 376 - 382
  • [35] Lumen apposing metal stents vs. double pigtail plastic stents for the drainage of pancreatic walled-off necrosis
    Valente, Roberto
    Zarantonello, Laura
    Del Chiaro, Marco
    Vujasinovic, Miroslav
    Baldaque-Silva, Francisco
    Scandavini, Chiara M.
    Rangelova, Elena
    Vespasiano, Francesca
    Anzillotti, Giuseppe
    Lohr, Johannes M.
    Arnelo, Urban
    MINERVA GASTROENTEROLOGY, 2024, 70 (01): : 1 - 9
  • [36] Validation of the Orlando Protocol for endoscopic management of pancreatic fluid collections in the era of lumen-apposing metal stents
    Bang, Ji Young
    Wilcox, C. Mel
    Arnoletti, Juan Pablo
    Peter, Shajan
    Christein, John
    Navaneethan, Udayakumar
    Hawes, Robert
    Varadarajulu, Shyam
    DIGESTIVE ENDOSCOPY, 2022, 34 (03) : 612 - 621
  • [37] Safety and adverse events of EUS-guided gallbladder drainage using lumen-apposing metal stents and percutaneous cholecystostomy tubes: a systematic review and meta-analysis
    Hayat, Umar
    Al Shabeeb, Reem
    Perez, Paola
    Hensien, Jack
    Dwivedi, Aanini
    Sakhawat, Usama
    Ahmad, Oneeb
    Haseeb, Muhammad
    Siddiqui, Ali A.
    Adler, Douglas G.
    GASTROINTESTINAL ENDOSCOPY, 2024, 99 (03) : 444 - 448.e1
  • [38] Multicenter study of the efficacy and safety of electrocautery-enhanced lumen-apposing metal stents for the internal drainage of pancreatic fluid collections
    Chen-Shuan Chung
    Yu-Ting Kuo
    Yi-Chun Chiu
    Yang-Chao Lin
    Chi-Ying Yang
    Kuan-Chih Chen
    Szu-Chia Liao
    Cheuk-Kay Sun
    Yen-Chih Lin
    Hsiu-Po Wang
    Scientific Reports, 14
  • [39] Multicenter study of the efficacy and safety of electrocautery-enhanced lumen-apposing metal stents for the internal drainage of pancreatic fluid collections
    Chung, Chen-Shuan
    Kuo, Yu-Ting
    Chiu, Yi-Chun
    Lin, Yang-Chao
    Yang, Chi-Ying
    Chen, Kuan-Chih
    Liao, Szu-Chia
    Sun, Cheuk-Kay
    Lin, Yen-Chih
    Wang, Hsiu-Po
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [40] Efficacy and Safety of Lumen Apposing Self-Expandable Metal Stents for EUS Guided Cholecystostomy: A Meta-Analysis and Systematic Review
    Kalva, Nikhil R.
    Vanar, Vishwas
    Forcione, David
    Bechtold, Matthew L.
    Puli, Srinivas Reddy
    CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2018, 2018