Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience

被引:50
|
作者
Iannaccone, R [1 ]
Laghi, A [1 ]
Catalano, C [1 ]
Mangiapane, F [1 ]
Piacentini, F [1 ]
Passariello, R [1 ]
机构
[1] Univ Roma La Sapienza, Policlin Umberto I, Dept Radiol, I-00161 Rome, Italy
关键词
computed tomography; colonography; multislice CT; colon; polyps; carcinoma; radiation dose reduction;
D O I
10.1007/s00330-002-1704-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom, Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, sensitivity 100%). The CT colonography also detected 10 of 12 polyps (overall sensitivity 83.3%). Based on polyp diameter, the sensitivity for the detection of polyps 10 mm or larger was 100% (3 of 3); between 6 and 9 mm, 100% (3 of 3); and 5 mm or smaller, 66.6% (4 of 6). Total radiation exposure for prone and supine acquisitions combined was 1.7 mSv (for men) and 2.3 mSv (for women). Although preliminary, our experience suggests that ultra-low-dose scanning for multislice CT colonography is feasible. This technique provides a sensitivity comparable to that of previous experiences with CT colonography but with a 40-70% reduction of the radiation dose delivered to patients.
引用
收藏
页码:1297 / 1302
页数:6
相关论文
共 50 条
  • [1] Diagnostic accuracy of ultra-low-dose CT colonography for the detection of colorectal polyps: a feasibility study
    Yasuda, Takaaki
    Honda, Tetsuro
    Utano, Kenichi
    Kato, Takashi
    Togashi, Kazutomo
    Yamaguchi, Shota
    Yasaka, Takahiro
    JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (08) : 831 - 839
  • [2] Iterative Reconstruction for Ultra-Low-Dose Laxative-Free CT Colonography
    Synho Do
    Naeppi, Janne J.
    Yoshida, Hiroyuki
    ABDOMINAL IMAGING: COMPUTATION AND CLINICAL APPLICATIONS, 2013, 8198 : 99 - 106
  • [3] Feasibility of ultra-low-dose multi-detector-row CT-colonography:: Detection of artificial endoluminal lesions in an in-vitro-model with optimization of image quality using a noise reduction filter algorithm
    Branschofsky, M
    Vogt, C
    Aurich, N
    Beck, A
    Mödder, U
    Cohnen, T
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2006, 11 (01) : 13 - 19
  • [4] Low radiation dose multislice CT colonography in children:: Experience after 100 studies
    Capuñay, CM
    Carrascosa, PM
    Bou-Khair, A
    Castagnino, N
    Ninomiya, I
    Carrascosa, JM
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 56 (03) : 398 - 402
  • [5] Evaluation of Ultra-Low-Dose Chest CT Images to Detect Lung Lesions
    Jalli, Reza
    Zarei, Fariba
    Chatterjee, Sabyasachi
    Haghighi, Rezvan Ravanfar
    Novshadi, Alireza
    Iranpour, Pooya
    Sefidbakht, Sepideh
    Chatterjee, Vani Vardhan
    MIDDLE EAST JOURNAL OF CANCER, 2020, 13 (02) : 299 - 307
  • [6] Evaluation of Ultra-Low-Dose Chest CT Images to Detect Lung Lesions
    Jalli, Reza
    Zarei, Fariba
    Chatterjee, Sabyasachi
    Haghighi, Rezvan Ravanfar
    Novshadi, Alireza
    Iranpour, Pooya
    Sefidbakht, Sepideh
    Chatterjee, Vani Vardhan
    MIDDLE EAST JOURNAL OF CANCER, 2022, 13 (02) : 299 - 307
  • [7] CT colonography for synchronous colorectal lesions in patients with colorectal cancer: initial experience
    McArthur, D. R.
    Mehrzad, H.
    Patel, R.
    Dadds, J.
    Pallan, A.
    Karandikar, S. S.
    Roy-Choudhury, S.
    EUROPEAN RADIOLOGY, 2010, 20 (03) : 621 - 629
  • [8] Performance evaluation of multi-material electronic cleansing for ultra-low-dose dual-energy CT colonography
    Tachibana, Rie
    Kohlhase, Nadja
    Naeppi, Janne J.
    Hironaka, Toru
    Ota, Junko
    Ishida, Takayuki
    Regge, Daniele
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785
  • [9] Automated detection of colorectal lesions with dual-energy CT colonography
    Naeppi, Janne J.
    Kim, Se Hyung
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2012: COMPUTER-AIDED DIAGNOSIS, 2012, 8315
  • [10] Ultra-low-dose CT for extremities in an acute setting: initial experience with 203 subjects
    Alagic, Zlatan
    Bujila, Robert
    Enocson, Anders
    Srivastava, Subhash
    Koskinen, Seppo K.
    SKELETAL RADIOLOGY, 2020, 49 (04) : 531 - 539