Effect of pulsatile perfusion during cardiopulmonary bypass in terms of radial artery sphygmogram

被引:2
作者
Zhang, Zhifeng [1 ]
Xu, Jiatuo [1 ]
Zhu, Enyuan [1 ]
Zhang, Qi [2 ]
Yu, Lu [2 ]
Qiu, Yongbing [1 ]
Tang, Jianguo [1 ]
Fei, Zhaofu [1 ]
Li, Xin [3 ]
Tu, Liping [1 ]
Han, Chouping [1 ]
Liu, Ying [1 ]
Guo, Zhen [3 ]
Zhou, Changle [1 ]
Shi, Meiyu [1 ]
Qian, Yingxin [1 ]
Bao, Yimin [1 ]
Ji, Xinming [2 ]
机构
[1] Shanghai Univ Tradit Chinese Med, Basic Med Sci Sch, Shanghai 201203, Peoples R China
[2] Fudan Univ, Dept Microelect, Shanghai 200433, Peoples R China
[3] Shanghai Jiao Tong Univ, Dept Cardiopulmonary Bypass, Shanghai Chest Hosp, Shanghai 200030, Peoples R China
基金
中国国家自然科学基金;
关键词
Cardiopulmonary bypass; Pulsatile flow; Radial artery; Pulse waveforms; Sphygmogram; OXYGEN-SATURATION; BLOOD-FLOW; PRESERVATION; SURGERY; PUMP;
D O I
10.1016/S0254-6272(15)30081-9
中图分类号
R [医药、卫生];
学科分类号
10 ;
摘要
OBJECTIVE: To investigate a quantitative method for using radial artery pulse waveforms to assess the effect of pulsatile flow during cardiopulmonary bypass (CPB). METHODS: A total of 34 adults with heart disease who underwent open-heart surgery between April 2010 and January 2011 were randomized into a pulsatile perfusion group (n=17) and a non-pulsatile perfusion group (n=17). Radial arterial pulse waveforms of pulsatile and non-pulsatile perfusion patients were observed and compared before and during CPB. RESULTS: No pulse waveform could be detected at patients' radial artery in both groups when the aorta was cross-clamped. Pulse waveforms could be detected at pulsatile perfusion patients' radial artery, but could not be detected at non-pulsatile perfusion patients' radial artery during CPB. Additionally, patients' pulse waveforms during pulsatile perfusion were lower than those before the operation. CONCLUSION: Our findings indicate that radial artery sphygmogram can be used as a valid indicator to evaluate the effectiveness of pulsatile perfusion during CPB. (C) 2014 JTCM. All rights reserved.
引用
收藏
页码:673 / 677
页数:5
相关论文
共 50 条
  • [41] The effect of oxygenator choice on hypotension during cardiopulmonary bypass
    Mijovski, G.
    Colah, S.
    Sharples, L.
    Wheaton, E.
    Martinez, G.
    Klein, A. A.
    PERFUSION-UK, 2011, 26 (03): : 223 - 227
  • [42] Gut mucosal perfusion in infants undergoing cardiopulmonary bypass: Effect of preoperative captopril
    Booker, PD
    Davis, AJM
    Franks, R
    BRITISH JOURNAL OF ANAESTHESIA, 1997, 79 (01) : 14 - 18
  • [43] Is increased perfusion pressure really necessary during cardiopulmonary bypass?
    Alhan, Cem H.
    Toraman, Fevzi
    Karabulut, Hasan
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (05) : 1213 - 1214
  • [44] Neonatal Aortic Arch Hemodynamics and Perfusion During Cardiopulmonary Bypass
    Pekkan, Kerem
    Dur, Onur
    Sundareswaran, Kartik
    Kanter, Kirk
    Fogel, Mark
    Yoganathan, Ajit
    Undar, Akif
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (06):
  • [45] Pulsatile versus non-pulsatile perfusion in coronary artery bypass operation: The comparison of laboratory and clinical outcomes
    Shahandashti, Farshad Jalili
    Asadian, Sanaz
    Habibi, Neda
    Gorjipour, Farhad
    Jalali, Amirhossein
    Toloueitabar, Yaser
    PERFUSION-UK, 2023, 38 (05): : 1053 - 1061
  • [46] Regulation of perfusion pressure during cardiopulmonary bypass using sevoflurane
    Ueda, T
    Mizuguchi, K
    Tsuji, T
    Tabayashi, N
    Abe, T
    Naito, H
    Takewa, Y
    Taniguchi, S
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2001, 24 (01) : 30 - 33
  • [47] Venous obstruction and cerebral perfusion during experimental cardiopulmonary bypass
    Tovedal, Thomas
    Jonsson, Ove
    Zemgulis, Vitas
    Myrdal, Gunnar
    Thelin, Stefan
    Lennmyr, Fredrik
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 11 (05) : 561 - 566
  • [48] Aortic Outflow Cannula Tip Design and Orientation Impacts Cerebral Perfusion During Pediatric Cardiopulmonary Bypass Procedures
    Menon, Prahlad G.
    Antaki, James F.
    Undar, Akif
    Pekkan, Kerem
    ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (12) : 2588 - 2602
  • [49] Optical monitoring of cerebral perfusion and metabolism in adults during cardiac surgery with cardiopulmonary bypass
    Rajaram, Ajay
    Milej, Daniel
    Suwalski, Marianne
    Yip, Lawrence C. M.
    Guo, Linrui R.
    Chu, Michael W. A.
    Chui, Jason
    Diop, Mamadou
    Murkin, John M.
    St Lawrence, Keith
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (10) : 5967 - 5981
  • [50] Somatic and cerebral near infrared spectroscopy for the monitoring of perfusion during neonatal cardiopulmonary bypass
    Bojan, Mirela
    Bonaveglio, Enrico
    Dolcino, Andrea
    Mirabile, Cristian
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 29 (06) : 955 - 959