A non-invasive measure of changes in blood flow in the human anterior tibial muscle

被引:41
作者
Zhang, QX [1 ]
Lindberg, LG
Kadefors, R
Styf, J
机构
[1] Sahlgrens Univ Hosp, Dept Orthopaed, S-41345 Gothenburg, Sweden
[2] Linkoping Univ, Dept Biomed Engn, Linkoping, Sweden
[3] Natl Inst Working Life, Gothenburg, Sweden
关键词
muscle blood flow; reactive hyperaemia; photoplethysmography; laser-Doppler flowmetry; muscle exercise;
D O I
10.1007/s004210100413
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We used photoplethysmography (PPG) to monitor blood flow changes in the human anterior tibial muscle during arterial occlusion and during isometric and concentric contractions. Single-fibre laser-Doppler flowmetry (LDF) was used as a reference in 12 healthy subjects (5 men, 7 women; mean age 24 years). Postexercise hyperaemic muscle blood flow (MBF) was measured immediately after isometric dorsiflexion of the ankle joint at maximal contraction for 1 min and full range-of-motion dorsiflexion and plantar flexion of the ankle joint for 1 min. A thigh tourniquet was applied for the evaluation of post-occlusive reactive hyperaemia. The MBF (baseline = 100%) was [mean (SD)] 150 (31) % (P = 0.003) by PPG (880 nm) and 182 (66) % (P = 0.012) by LDF. After 1 min of maximal isometric contraction, MBF increased to 150 (51) % (P = 0.003) by PPG (880 nm) and to 169 (43) % (P = 0.005) by LDF. After 1 min of maximal concentric contractions, MBF increased to 158 (59) % (P = 0.003) by PPG (880 nm) and to 170 (99) % (P = 0.008) by LDF. Skin blood flow, PPG (560 nm), did not change significantly after isometric or concentric contractions. The results indicate that reactive hyperaemia after exercise and arterial occlusion can be assessed in the human anterior tibial muscle using PPG.
引用
收藏
页码:448 / 452
页数:5
相关论文
共 21 条
[11]   ASSESSMENT OF HUMAN MUSCLE BLOOD PERFUSION WITH SINGLE-FIBER LASER DOPPLER FLOWMETRY [J].
KVERNEBO, K ;
STAXRUD, LE ;
SALERUD, EG .
MICROVASCULAR RESEARCH, 1990, 39 (03) :376-385
[12]   MEASUREMENT BY LASER-DOPPLER FLOWMETRY OF MICROCIRCULATION IN LOWER LEG MUSCLE AT DIFFERENT BLOOD FLUXES IN RELATION TO ELECTROMYOGRAPHICALLY DETERMINED CONTRACTION AND ACCUMULATED FATIGUE [J].
LARSSON, SE ;
CAI, HM ;
ZHANG, QU ;
LARSSON, R ;
OBERG, PA .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1995, 70 (04) :288-293
[13]  
LASSEN NA, 1964, LANCET, V1, P686
[14]   SKELETAL-MUSCLE BLOOD-FLOW CAPACITY - ROLE OF MUSCLE PUMP IN EXERCISE HYPEREMIA [J].
LAUGHLIN, MH .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (05) :H993-H1004
[15]   PHOTOPLETHYSMOGRAPHY .2. INFLUENCE OF LIGHT-SOURCE WAVELENGTH [J].
LINDBERG, LG ;
OBERG, PA .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (01) :48-54
[16]   EVALUATION OF A LASER DOPPLER FLOWMETER FOR MEASUREMENT OF TISSUE BLOOD-FLOW [J].
NILSSON, GE ;
TENLAND, T ;
OBERG, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (10) :597-604
[17]  
OBERG PA, 1990, CRIT REV BIOMED ENG, V18, P125
[18]  
SALERUD EG, 1987, MED BIOL ENG COMPUT, V25, P329, DOI 10.1007/BF02447433
[19]  
SANDBERG M, 2000, PAIN EUR 3 3 C EUR F, P328
[20]   ACUTE EFFECTS OF LOCAL TISSUE TRAUMA ON SKIN PERFUSION EVALUATED WITH LASER-DOPPLER FLOWMETRY [J].
STAXRUD, LE ;
KVERNEBO, K ;
SALERUD, EG .
MICROVASCULAR RESEARCH, 1991, 42 (02) :179-186