Gamma-ray Spectroscopy Using Inorganic Scintillator Coated with Reduced Graphene Oxide in Fiber-Optic Radiation Sensor

被引:3
作者
Kim, Jin Ho [1 ]
Kim, Seunghyeon [1 ]
Song, Siwon [1 ]
Lim, Taeseob [1 ]
Park, Jae Hyung [1 ]
Kim, Jinhong [1 ]
Pyeon, Cheol Ho [2 ]
Hwang, Sung Won [3 ]
Lee, Bongsoo [1 ]
机构
[1] Chung Ang Univ, Sch Energy Syst Engn, Seoul 06974, South Korea
[2] Kyoto Univ, Inst Integrated Radiat & Nucl Sci, Res Ctr Safe Nucl Syst, Asashiro Nishi, Kumatori, Osaka 5900494, Japan
[3] Sangmyung Univ, Dept Syst Semicond Engn, Cheonan 31066, South Korea
基金
新加坡国家研究基金会;
关键词
reduced graphene oxide; gamma-ray spectroscopy; fiber-optic radiation sensor; inorganic scintillator; plastic optical fiber; SYSTEM;
D O I
10.3390/photonics8120543
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this study, we developed a remote gamma-ray spectroscopy system based on a fiber-optic radiation sensor (FORS) that is composed of an inorganic scintillator coated with reduced graphene oxide (RGO) and a plastic optical fiber (POF). As a preliminary experiment, we measured the transmitted light intensities using RGO membranes of different thicknesses with different wavelengths of emitted light. To evaluate the FORS performance, we determined the optimal thickness of the RGO membrane and measured the amounts of scintillating light and gamma energy spectra using radioactive isotopes such as Co-60 and Cs-137. The amounts of scintillating light from the RGO-coated inorganic scintillators increased, and the energy resolutions of the gamma-ray spectra were enhanced. In addition, the gamma-ray energy spectra were measured using different types of RGO-coated inorganic scintillators depending on the lengths of the POFs for remote gamma-ray spectroscopy. It was expected that inorganic scintillators coated with RGO in FORS can deliver improved performance, such as increments of scintillating light and energy resolution in gamma-ray spectroscopy, and they can be used to identify nuclides remotely in various nuclear facilities.
引用
收藏
页数:11
相关论文
共 41 条
[21]   Humidity sensor based on power leakage at resonance wavelengths of a hollow core fiber coated with reduced graphene oxide [J].
Gao, Ran ;
Lu, Dan-feng ;
Cheng, Jin ;
Jiang, Yi ;
Jiang, Lang ;
Qi, Zhi-mei .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 :618-624
[22]   Measurement of Two-Dimensional Photon Beam Distributions Using a Fiber-Optic Radiation Sensor for Small Field Radiation Therapy [J].
Lee, Bongsoo ;
Jang, Kyoung Won ;
Cho, Dong Hyun ;
Yoo, Wook Jae ;
Shin, Sang Hun ;
Kim, Hyung Sik ;
Yi, Jeong Han ;
Kim, Sin ;
Cho, Hyosung ;
Park, Byung Gi ;
Moon, Joo Hyun ;
Kim, Siyong .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) :2632-2636
[23]   In vitro glucose measurement using tunable mid-infrared laser spectroscopy combined with fiber-optic sensor [J].
Yu, Songlin ;
Li, Dachao ;
Chong, Hao ;
Sun, Changyue ;
Yu, Haixia ;
Xu, Kexin .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01) :275-286
[24]   Effect of gamma-ray irradiated reduced graphene oxide (rGO) on environmental health: An in-vitro and in-vivo studies* [J].
Sivaselvam, S. ;
Mohankumar, A. ;
Narmadha, R. ;
Sevakumar, R. ;
Sundararaj, P. ;
Viswanathan, C. ;
Ponpandian, N. .
ENVIRONMENTAL POLLUTION, 2023, 318
[25]   Reduced Graphene Oxide nano-composites layer on fiber optic tip sensor reflectance response for sensing of aqueous ethanol [J].
Rosli, M. A. A. ;
Arasu, P. T. ;
Noor, A. S. M. ;
Lim, H. N. ;
Huang, N. M. .
JOURNAL OF THE EUROPEAN OPTICAL SOCIETY-RAPID PUBLICATIONS, 2016, 12
[26]   High Energy Gamma-Ray Spectroscopy Using Transition-Edge Sensor With a Superconducting Bulk Tantalum Absorber [J].
Irimatsugawa, T. ;
Hatakeyama, S. ;
Ohno, M. ;
Takahashi, H. ;
Otani, C. ;
Maekawa, T. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (03)
[27]   Violet laser power sensor based on micro-fiber coated with methyl blue-functionalized reduced graphene oxide [J].
Tian, Zhengwen ;
Zhang, Jun ;
Yang, Bing ;
Yu, Jianhui ;
Chen, Zhe ;
Tang, Jieyuan ;
Luo, Yunhan ;
Cai, Xiang ;
Tan, Shaozao ;
Lu, Huihui .
23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2014, 9157
[28]   Real-time detection of 192Ir gamma-ray source positon using organic scintillator array sensor in HDR brachytherapy [J].
Song, Young Beom ;
Shin, Sang Hun ;
Shin, Hyun Young ;
Park, Jae Hyung ;
Byun, Hyungi ;
Song, Si Won ;
Kim, Ji Ye ;
Lee, Bongsoo .
BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2018, 10711
[29]   Gamma-Ray Spectroscopy Using an Unfolding Method with Response Functions Including the Energy Dependencies of Scintillation Efficiency for the NaI(T1) Scintillator [J].
Hayashi, Masateru ;
Sasano, Makoto ;
Azuma, Tetsushi ;
Makita, Taisuke ;
Nakanishi, Masakazu ;
Nishizawa, Hiroshi .
JOURNAL OF RADIATION PROTECTION AND RESEARCH, 2025, 50 :S68-S79
[30]   Zirconium preconcentration from zircon raffinate using gamma radiation–induced polymerization of reduced graphene oxide composite [J].
Amr Hamdi Ali ;
Shaimaa Mohammed Abdo ;
Gehan Abdel Rahman Sadek Dakroury .
Environmental Science and Pollution Research, 2023, 30 :58330-58345