In-plane cyclic behavior of structural insulated panel wood walls including slit steel connectors

被引:3
|
作者
Purasinghe, Rupa [1 ]
Dusicka, Peter [2 ]
Garth, John S. [2 ]
Dedek, Gennelle [1 ]
Lum, Howard [1 ]
机构
[1] Calif State Univ Los Angeles, Dept Civil Engn, Los Angeles, CA 90032 USA
[2] Portland State Univ, Dept Civil & Environm Engn, Portland, OR 97207 USA
基金
美国国家科学基金会;
关键词
Structural Insulated Panels; Cyclic loading; Slit steel connectors; Block spline; Plastic deformation; Ductility; Drift capacity; Backbone curves; Pull out of nails; Hold downs;
D O I
10.1016/j.engstruct.2018.07.027
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objective of this paper was to experimentally investigate the behavior of structural insulated panel (SIP) walls under in-plane cyclic loading and to test several panel-to-panel connections in order to measure their effect on the behavior of the walls. Each wall was constructed using two SIP panels with one top plate, one sill plate, two end plates, and a panel-to-panel connection. Each SIP panel had a 5.5 in. (14 cm) thick expanded polystyrene core sandwiched between two 4' x 8' (1.22 m x 2.44 m) sheets of 7/16 '' (1.11 cm) oriented strand board. The top sill plates were split up between each panel in an effort to increase the potential for racking behavior of the walls and, therefore, the relative vertical displacement between the panels. In addition, as a preliminary study, three different steel connector configurations utilizing 26 gauge steel shear panels were considered in an effort to introduce additional ductility compared to more traditional block spline connection. From experimental observation of the wall with the block spline connection and the wall with no connection, the panel-to-panel connection was shown to contribute significant strength and stiffness to the wall system. The walls that were constructed with the first two configurations of the shear panels did not show any significant increase in either stiffness or ductility over the wall with the block spline. These walls also showed a decline in peak strength, which occurred at lower lateral displacements than the peak strength of the typical wall. For both of these cases, the shear panels yielded early and ruptured at the lateral deformation which caused peak load in each wall. The SIP wall implementing the third style of shear panel also did not demonstrate a significant increase in ductility as compared to the standard SIP wall. Despite the initially outlined potential, the preliminary study of implementation of the slit steel shear panels considered in this study did not significantly alter the performance of the conventionally connected SIP walls. Further study with stiff connectors capable of significant ductility prior to fracture would need to be implemented to realize the benefits of increased wall ductility.
引用
收藏
页码:178 / 197
页数:20
相关论文
共 50 条
  • [31] Macro-Modelling Approach for the In-Plane Cyclic Response of Cold-Formed Steel Partition Walls
    Shin, Dong-Hyeon
    Kim, Hyung-Joon
    APPLIED SCIENCES-BASEL, 2020, 10 (22): : 1 - 21
  • [32] Testing of light-gauge steel-frame - wood structural panel shear walls
    Branston, A. E.
    Chen, C. Y.
    Boudreault, F. A.
    Rogers, C. A.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2006, 33 (05) : 561 - 572
  • [33] Behaviour of light-gauge steel-frame - wood structural panel shear walls
    Chen, C. Y.
    Boudreault, F. A.
    Branston, A. E.
    Rogers, C. A.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2006, 33 (05) : 573 - 587
  • [34] Cyclic Behavior of Multirow Slit Shear Walls Made from Low-Yield-Point Steel
    He, Liusheng
    Togo, Takuma
    Hayashi, Kazuhiro
    Kurata, Masahiro
    Nakashima, Masayoshi
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (11)
  • [35] Effects of Accident Thermal Loading on In-Plane Shear Behavior of Steel-Plate Composite Walls
    Bhardwaj, Saahastaranshu R.
    Sener, Kadir C.
    Varma, Amit H.
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2023, 60 (02): : 73 - 92
  • [36] Effects of Accident Thermal Loading on In-Plane Shear Behavior of Steel-Plate Composite Walls
    Bhardwaj, Saahastaranshu R.
    Sener, Kadir C.
    Varma, Amit H.
    Engineering Journal, 2023, 60 (02): : 73 - 92
  • [37] In-plane shear behavior of masonry walls strengthened with steel fiber-reinforced concrete overlay
    Najafgholipour M.A.
    Dehghan S.M.
    Kamrava A.R.
    Asian Journal of Civil Engineering, 2018, 19 (5) : 553 - 570
  • [38] Investigation on in-plane structural behavior of steel arches with rectangular web-openings
    Tong, Lewei
    Wang, Yifei
    Yan, Yang
    Sheng, Shuowen
    Ning, Peng
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 201
  • [39] Structural performance of confined masonry walls retrofitted using ferrocement and GFRP under in-plane cyclic loading
    El-Diasity, Mosaad
    Okail, Hussein
    Kamal, Osama
    Said, Mohamed
    ENGINEERING STRUCTURES, 2015, 94 : 54 - 69
  • [40] Experimental behavior of innovative T-shaped composite shear walls under in-plane cyclic loading
    Zhang, Xiaomeng
    Qin, Ying
    Chen, Zhihua
    Jie, Li
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 120 : 143 - 159